Jikai Zhang

Dr. Jikai Zhang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JZJikai Zhang
Jikai Zhang
YSYicheng Shi
Yicheng Shi
YHYuewen Huang
Yuewen Huang
CLCheng Liang
Cheng Liang
YDYantong Dong
Yantong Dong
Bo FengBo Feng
Bo Feng
This paper proposes a displacement sensing method based on magnetic flux measurement. A bridge-structured magnetic circuit, formed by permanent magnets and two ferromagnetic cores, is designed and discussed. The analyses of the equivalent magnetic circuit and three-dimensional finite element simulations showed that the magnetic flux density changes linearly with the reciprocal of the sum of a constant and the displacement. A prototype sensor of the bridge structure is developed that consists of four permanent magnets as excitation, a Hall sensor as reception, and two ferromagnetic cores as the connection. Experiments have validated the feasibility of this method. The measured results show a good linearity between the sensor’s output and the reciprocal of the sum of a constant and the displacement, with a correlation coefficient greater than 0.9995 across different measurement ranges. Additionally, the measured results significantly indicate that the proposed sensor is compatible with different ferromagnetic materials with a worst-case error of less than 5%. The proposed sensor has the advantages of low cost and good linearity; however, the test object is limited to ferromagnetic materials.

12 July 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
JZJikai Zhang
Jikai Zhang
RWRongbiao Wang
Rongbiao Wang
ZDZhiyang Deng
Zhiyang Deng
YKYihua Kang
Yihua Kang
Displacement sensors play an essential role in many applications. Based on an alternating current magnetic flux measurement, a novel displacement sensing method aimed at developing a practical displacement sensor for ferromagnetic materials is proposed. In this method, the displacement is measured by detecting the magnetic flux in a magnetic circuit, according to a linear relation between the magnetic flux and the reciprocal of displacement. An equivalent magnetic circuit and finite element method are used in analyzing a bridge-structured sensor designed in this paper. Both show that the output of the sensor is linear with the reciprocal of the displacement. A series of experiments have verified the feasibility of the proposed method. The measured results of our prototype sensor show a linear relation with the correlation coefficient R 2 over 0.995 in a measurement range larger than 3 mm. Furthermore, the results significantly indicate that the measured results are not influenced much by the change of ferromagnetic materials with the worst-case error less than 5%.

7 January 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YXYiru Xiao
Yiru Xiao
Bo FengBo Feng
Bo Feng
JZJikai Zhang
Jikai Zhang
KMKun Mao
Kun Mao
KWKai Wang
Kai Wang
YKYihua Kang
Yihua Kang
The method of motion-induced eddy current is significant not only for defect detection but also for speed sensing. This paper investigates the effect of excitation frequency on the distribution of motion-induced eddy current and the speed sensing results. Firstly, a two-dimensional analytical model of motion-induced eddy current with AC excitation is proposed, based on Maxwell’s equations. The speed sensor in the model is composed of an excitation coil and a Hall element. The density of the eddy currents within the conductor and the magnetic field strength in the air are calculated. Subsequently, finite element analyses are employed to verify the accuracy of the theoretical model. The distribution of eddy current and speed sensing results with DC and AC excitation are analyzed, along with the effect of excitation frequency and conductor moving speed on the eddy current in the specimen and the magnetic field in the air. It was found that the speed sensor based on DC excitation exhibits higher sensitivity in the speed range of 0-30 m/s, while the speed measurement results under 0-120 Hz AC excitation demonstrate improved linearity. Additionally, the interference of motion-induced eddy currents on induced eddy currents decreases as the excitation frequency increases. Speed sensing experiments are conducted on a rotating disc, and the experimental results are in good agreement with the theoretical calculations.

16 July 2025 in IEEE Open Journal of Instrumentation and Measurement
Verified
Journal Article
Open access
YXYiru Xiao
Yiru Xiao
JZJikai Zhang
Jikai Zhang
YHYaoting Han
Yaoting Han
YCYanting Chen
Yanting Chen
KDKangxuan Deng
Kangxuan Deng
Bo FengBo Feng
Bo Feng
Motion-induced eddy current (MIEC) testing method has been successfully applied in speed measurement, where the performance of the sensor is highly dependent on the dimensions of the permanent magnet. In this article, an optimization method based on the gradient projection algorithm is proposed to determine the optimal magnet dimensions and enhance measurement sensitivity. First, the principle of MIEC is analyzed based on a 2-D theoretical model. Subsequently, an optimization-based mathematical model employing the gradient projection algorithm is developed, and the corresponding optimized results are obtained. Finally, experimental validation is conducted using a rotating aluminum disk platform. The results indicate that, within the practical dimensional ranges of 40 mm in width and 30 mm in height, the optimized permanent magnet dimensions are with a width of 27.6 mm and a height of 30 mm, which yield the best measurement sensitivity.

2 September 2022 in Water
Verified
Journal Article
Open access
PDF file
JZJikai Zhang
Jikai Zhang
YHYuewen Huang
Yuewen Huang
JTJian Tang
Jian Tang
FZFangfang Zhou
Fangfang Zhou
YKYihua Kang
Yihua Kang
Bo FengBo Feng
Bo Feng
This paper proposes a method of injected alternating current-field measurement (IAC-FM) for detecting orthogonal cracks in the piston rod of a hydraulic cylinder in a gate hoist. Using this method, both longitudinal and transverse cracks can be detected at the same time. An alternating magnetic field is produced inside the steel rod by axially injecting an alternating current into the rod. The longitudinal crack perturbs the circumferential magnetic field, whereas the transverse crack perturbs the current in the axial direction. Analyses of the behaviors of the magnetic field in the vicinity of the cracks were proposed, using a three-dimensional finite element software. An experimental setup was built and validation experiments were performed. The effects of the operating frequency and scan path were also studied. The results verified the feasibility of the IAC-FM method and showed great potential for the inspection of in-service hydraulic cylinders of gate hoists.

6 August 2026 in Proceedings of the Institution of Civil Engineers - Structures and Buildings
Verified
Journal Article
Closed access
QZQi-Ling Zhang
Qi-Ling Zhang
XGXiao-Feng Gao
Xiao-Feng Gao
JZJikai Zhang
Jikai Zhang
LHLei Hu
Lei Hu
This study investigates the structural implications for hydropower plants under evolving operational paradigms driven by renewable energy integration, focusing on substructure stiffness degradation caused by cyclic internal water pressure (IWP). A plane axisymmetric finite-element model of the intake section from an actual plant is developed in the Abaqus software program, employing the extended finite-element method to simulate concrete crack initiation and propagation. Numerical results demonstrate that the elastic modulus of the membrane material is the predominant factor influencing substructure stiffness degradation. While the inner reinforcement surrounding the steel spiral case contributes significantly to long-term stiffness retention, the frictional interaction at the steel–concrete interface exerts only a marginal influence when the weld slope-cutting details are considered. Furthermore, the fracture energy of concrete shows no substantial impact on stiffness degradation, provided its value remains within the conventional range for mass concrete (e.g. >150 N/m). Importantly, the numerical analysis indicates that the observed stiffness degradation does not translate into significant adverse effects on two key engineering concerns: generator pedestal uplift and the fatigue life of the steel spiral case. These findings provide critical insights for assessing the long-term performance of hydropower infrastructure under evolving operational demands.