Angel Ramos Macias

Angel Ramos Macias

Auto-generated profile, based on publicly available information

Angel Ramos Macias

Department of Otolaryngology, and Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, Hearing and Balance Laboratory University of Las Palmas de Gran Canaria Las Palmas Spain

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2023 in The Laryngoscope
Verified
Journal Article
Open access
ÁMÁngel Ramos de Miguel
Ángel Ramos de Miguel
IMIsaura Rodriguez Montesdeoca
Isaura Rodriguez Montesdeoca
JGJuan Carlos Falcón González
Juan Carlos Falcón González
SBSilvia Borkoski Barreiro
Silvia Borkoski Barreiro
AZAndrzej Zarowski
Andrzej Zarowski
AMAngel Ramos Macias
Angel Ramos Macias
Objectives: Possible beneficial “crosstalk” during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this case–control study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end‐organ), when using a cochleo‐vestibular implant, comparing vestibular stimulation (VI) and cochlear stimulation (CI).Methods: Four patients with bilateral vestibulopathy were included. A double electrode array research implant was implanted in all cases. Dynamic Gait Index (DGI), VOR gain measured by using vestibular head impulse test (vHIT), acoustic cervical myogenic responses (cVEMP) recordings, and electrical cVEMP were used in all cases. Trans‐impedance Matrix (TIM) analysis was used to evaluate the current flow from the cochlea to the vestibule.Results: While patients did not have any clinical vestibular improvement with the CI stimulation alone, gait metrics of the patients revealed improvement when the vestibular electrode was stimulated. The average improvement in the DGI was 38% when the vestibular implant was activated, returning to the normal range in all cases. Our findings suggest that any current flow from the cochlear space to the otolith organs was insufficient for effective cross‐stimulation. The functional results correlated with the data obtained in TIM analysis, confirming that there is no current flow from the cochlea to the vestibule.Conclusion: The only way to produce effective electrical otolith end‐organ stimulation, demonstrated with this research implant, is by direct electrical stimulation of the otolith end organs. No effective cross‐stimulation was found from cochlear electrode stimulation.Level of Evidence: 4 Laryngoscope, 134:2349–2355, 2024

27 May 2022 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
AMAngel Ramo de Miguel
Angel Ramo de Miguel
JEJosé M. Escobar
José M. Escobar
David GreinerDavid Greiner
David Greiner
Domingo BenitezDomingo Benitez
Domingo Benitez
Eduardo RodríguezEduardo Rodríguez
Eduardo Rodríguez
ÁRÁngel Ramos-Macías
Ángel Ramos-Macías
There is a growing interest in biomedical engineering in developing procedures that provide accurate simulations of the neural response to electrical stimulus produced by implants. Moreover, recent research focuses on models that take into account individual patient characteristics. We present a phenomenological computational model that is customized with the patient’s data provided by the electrically evoked compound action potential (ECAP) for simulating the neural response to electrical stimulus produced by the electrodes of cochlear implants (CIs). The model links the input currents of the electrodes to the simulated ECAP. Potentials and currents are calculated by solving the quasi-static approximation of the Maxwell equations with the finite element method (FEM). In ECAPs recording, an active electrode generates a current that elicits action potentials in the surrounding auditory nerve fibers (ANFs). The sum of these action potentials is registered by other nearby electrode. Our computational model emulates this phenomenon introducing a set of line current sources replacing the ANFs by a set of virtual neurons (VNs). To fit the ECAP amplitudes we assign a suitable weight to each VN related with the probability of an ANF to be excited. This probability is expressed by a cumulative beta distribution parameterized by two shape parameters that are calculated by means of a differential evolution algorithm (DE). Being the weights function of the current density, any change in the design of the CI affecting the current density produces changes in the weights and, therefore, in the simulated ECAP, which confers to our model a predictive capacity. The results of the validation with ECAP data from two patients are presented, achieving a satisfactory fit of the experimental data with those provided by the proposed computational model.

1 November 2022 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
SBSusana Benítez-Robaina
Susana Benítez-Robaina
ÁRÁngel Ramos-Macias
Ángel Ramos-Macias
SBSilvia Borkoski-Barreiro
Silvia Borkoski-Barreiro
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
PSPatricia Salvatierra
Patricia Salvatierra
AMAngel Ramo de Miguel
Angel Ramo de Miguel
BACKGROUND: The aim of this study was to assess the effect on speech perception and lack of hearing devices gain with surgical masks worn in hearing aid users. METHODS: This prospective cohort study enrolled consecutive patients between November 2020 and February 2021 in a tertiary care medical center from Spain. Fifty-five subjects have been included, 10 as control group, with normal hearing, and 45 patients with sensory-neural hearing loss and hearing aid users, ranging in age between 31 and 83 years old, and were recruited randomized in 4 months. Appropriate test was done previously to check adequate functioning from devices and suitable adaptation. Control group had no hearing impairment neither otologic disease. RESULTS: Disyllabic test in quiet get worse with face mask with a significant difference and stronger impact in noisy background. Age made no difference. Adding lipreading speech perception improved by 95.1 % for younger subjects (50 years of age). In the control sample, there was no differences in any condition. CONCLUSION: Despite advantages of wearing mask in preventing coronavirus disease 2019 spread, we must consider that they have also drawbacks for some groups like hearing aid users. In this research, we have not observed high frequencies perception decrease with surgical masks worn, but there was reduction in speech perception, most notably in hearing aids wearers in noisy environment. Cite this article as: Benítez-Robaina S, Ramos-Macias Á, Borkoski-Barreiro S, Falcón-González JC, Salvatierra P, Ramos-De Miguel A. COVID-19 era: Hearing handicaps behind face mask use in hearing aid users. J Int Adv Otol. 2022;18(6):465-470.