Erlend Fagertun Hofstad

Mr. Erlend Fagertun Hofstad

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2012 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
CVCecilie Våpenstad
Cecilie Våpenstad
MCMagdalena Karolina Chmarra
Magdalena Karolina Chmarra
TLThomas Lango
Thomas Lango
EKEsther Kuhry
Esther Kuhry
RMRonald Mårvik
Ronald Mårvik

8 February 2017 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
CVCecilie Våpenstad
Cecilie Våpenstad
LBLars Eirik Bø
Lars Eirik Bø
TLThomas Langø
Thomas Langø
EKEsther Kuhry
Esther Kuhry
RMRonald Mårvik
Ronald Mårvik
Background: A high level of psychomotor skills is required to perform minimally invasive surgery (MIS) safely. To be able to measure these skills is important in the assessment of surgeons, as it enables constructive feedback during training. The aim of this study was to test the validity of an objective and automatic assessment method using motion analysis during a laparoscopic procedure on an animal organ. Material and methods: Experienced surgeons in laparoscopy (experts) and medical students (novices) performed a cholecystectomy on a porcine liver box model. The motions of the surgical tools were acquired and analyzed by 11 different motion-related metrics, i.e., a total of 19 metrics as eight of them were measured separately for each hand. We identified for which of the metrics the experts outperformed the novices. Results: In total, two experts and 28 novices were included. The experts achieved significantly better results for 13 of the 19 instrument motion metrics. Conclusions: Expert performance is characterized by a low time to complete the cholecystectomy, high bimanual dexterity (instrument coordination), a limited amount of movement and low measurement of motion smoothness of the dissection instrument, and relatively high usage of the grasper to optimize tissue positioning for dissection.

30 June 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
HSHanne Sorger
Hanne Sorger
JBJanne Beate Lervik Bakeng
Janne Beate Lervik Bakeng
LGLucian Gruionu
Lucian Gruionu
HLHåkon Olav Leira
Håkon Olav Leira
TLThomas Langø
Thomas Langø

1 October 2011 in Journal of Bronchology & Interventional Pulmonology
Verified
Journal Article
Closed access
HLHåkon Olav Leira
Håkon Olav Leira
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
LBLars Eirik Bø
Lars Eirik Bø
TLThomas Langø
Thomas Langø
TATore Amundsen
Tore Amundsen
Current image guidance systems for bronchoscopy are limited to the diagnosis of small tumors and placing fiducials for radiation therapy and surgery. Ideally, a navigation system should be useable for the range of bronchoscopic procedures, including therapy with concurrent radiology imaging for control. As most guidance systems rely on electromagnetic (EM) fields, it is advised to leave the C-arm mounted fluoroscopy unit outside the operating field during navigation. We have assessed the accuracy of our research navigation platform, containing an EM field generator and a C-arm fluoroscopy unit. We have simulated a regular bronchoscopy session with an initial image-to-patient registration procedure, and a subsequent bronchoscopy with the C-arm inside the EM field. The registration accuracy was significantly influenced, introducing an error that may be carried through to the bronchoscopy procedure. During the bronchoscopy session, the C-arm caused a wave drift in the tracking positions and distorted the EM field, causing a translation error up to 22 mm. Even by averaging out the drift, there was a systematic shift in the x, y, and z positions. The errors were more evident in some C-arm positions and seem to be linked more to the electrical current in the fluoroscopy unit than the metallic C-arm itself. A fluoroscopy unit may be used during a navigation procedure, but care must be taken. To enable real-time navigation, the C-arm could be removed sufficiently from the EM tracking field or correction schemes must be implemented to compensate for the distortions.

6 August 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ØEØyvind Ervik
Øyvind Ervik
ITIngrid Elisabeth Tveten
Ingrid Elisabeth Tveten
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
TLThomas Lango
Thomas Lango
HLHåkon Olav Leira
Håkon Olav Leira
HSHanne Sorger
Hanne Sorger
Endobronchial ultrasound (EBUS) is used in the minimally invasive sampling of thoracic lymph nodes. In lung cancer staging, the accurate assessment of mediastinal structures is essential but challenged by variations in anatomy, image quality, and operator-dependent image interpretation. This study aimed to automatically detect and segment mediastinal lymph nodes and blood vessels employing a novel U-Net architecture-based approach in EBUS images. A total of 1161 EBUS images from 40 patients were annotated. For training and validation, 882 images from 30 patients and 145 images from 5 patients were utilized. A separate set of 134 images was reserved for testing. For lymph node and blood vessel segmentation, the mean ± standard deviation (SD) values of the Dice similarity coefficient were 0.71 ± 0.35 and 0.76 ± 0.38, those of the precision were 0.69 ± 0.36 and 0.82 ± 0.22, those of the sensitivity were 0.71 ± 0.38 and 0.80 ± 0.25, those of the specificity were 0.98 ± 0.02 and 0.99 ± 0.01, and those of the F1 score were 0.85 ± 0.16 and 0.81 ± 0.21, respectively. The average processing and segmentation run-time per image was 55 ± 1 ms (mean ± SD). The new U-Net architecture-based approach (EBUS-AI) could automatically detect and segment mediastinal lymph nodes and blood vessels in EBUS images. The method performed well and was feasible and fast, enabling real-time automatic labeling.

5 January 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ØEØyvind Ervik
Øyvind Ervik
MRMia Rødde
Mia Rødde
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
ITIngrid Elisabeth Tveten
Ingrid Elisabeth Tveten
TLThomas Lango
Thomas Lango
HSHanne Sorger
Hanne Sorger
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a cornerstone in minimally invasive thoracic lymph node sampling. In lung cancer staging, precise assessment of lymph node position is crucial for clinical decision-making. This study aimed to demonstrate a new deep learning method to classify thoracic lymph nodes based on their anatomical location using EBUS images. Bronchoscopists labeled lymph node stations in real-time according to the Mountain Dressler nomenclature. EBUS images were then used to train and test a deep neural network (DNN) model, with intraoperative labels as ground truth. In total, 28,134 EBUS images were acquired from 56 patients. The model achieved an overall classification accuracy of 59.5 ± 5.2%. The highest precision, sensitivity, and F1 score were observed in station 4L, 77.6 ± 13.1%, 77.6 ± 15.4%, and 77.6 ± 15.4%, respectively. The lowest precision, sensitivity, and F1 score were observed in station 10L. The average processing and prediction time for a sequence of ten images was 0.65 ± 0.04 s, demonstrating the feasibility of real-time applications. In conclusion, the new DNN-based model could be used to classify lymph node stations from EBUS images. The method performance was promising with a potential for clinical use.