Ingrid Elisabeth Tveten

Ms. Ingrid Elisabeth Tveten

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ØEØyvind Ervik
Øyvind Ervik
MRMia Rødde
Mia Rødde
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
ITIngrid Elisabeth Tveten
Ingrid Elisabeth Tveten
TLThomas Lango
Thomas Lango
HSHanne Sorger
Hanne Sorger
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a cornerstone in minimally invasive thoracic lymph node sampling. In lung cancer staging, precise assessment of lymph node position is crucial for clinical decision-making. This study aimed to demonstrate a new deep learning method to classify thoracic lymph nodes based on their anatomical location using EBUS images. Bronchoscopists labeled lymph node stations in real-time according to the Mountain Dressler nomenclature. EBUS images were then used to train and test a deep neural network (DNN) model, with intraoperative labels as ground truth. In total, 28,134 EBUS images were acquired from 56 patients. The model achieved an overall classification accuracy of 59.5 ± 5.2%. The highest precision, sensitivity, and F1 score were observed in station 4L, 77.6 ± 13.1%, 77.6 ± 15.4%, and 77.6 ± 15.4%, respectively. The lowest precision, sensitivity, and F1 score were observed in station 10L. The average processing and prediction time for a sequence of ten images was 0.65 ± 0.04 s, demonstrating the feasibility of real-time applications. In conclusion, the new DNN-based model could be used to classify lymph node stations from EBUS images. The method performance was promising with a potential for clinical use.

6 August 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ØEØyvind Ervik
Øyvind Ervik
ITIngrid Elisabeth Tveten
Ingrid Elisabeth Tveten
EHErlend Fagertun Hofstad
Erlend Fagertun Hofstad
TLThomas Lango
Thomas Lango
HLHåkon Olav Leira
Håkon Olav Leira
HSHanne Sorger
Hanne Sorger
Endobronchial ultrasound (EBUS) is used in the minimally invasive sampling of thoracic lymph nodes. In lung cancer staging, the accurate assessment of mediastinal structures is essential but challenged by variations in anatomy, image quality, and operator-dependent image interpretation. This study aimed to automatically detect and segment mediastinal lymph nodes and blood vessels employing a novel U-Net architecture-based approach in EBUS images. A total of 1161 EBUS images from 40 patients were annotated. For training and validation, 882 images from 30 patients and 145 images from 5 patients were utilized. A separate set of 134 images was reserved for testing. For lymph node and blood vessel segmentation, the mean ± standard deviation (SD) values of the Dice similarity coefficient were 0.71 ± 0.35 and 0.76 ± 0.38, those of the precision were 0.69 ± 0.36 and 0.82 ± 0.22, those of the sensitivity were 0.71 ± 0.38 and 0.80 ± 0.25, those of the specificity were 0.98 ± 0.02 and 0.99 ± 0.01, and those of the F1 score were 0.85 ± 0.16 and 0.81 ± 0.21, respectively. The average processing and segmentation run-time per image was 55 ± 1 ms (mean ± SD). The new U-Net architecture-based approach (EBUS-AI) could automatically detect and segment mediastinal lymph nodes and blood vessels in EBUS images. The method performed well and was feasible and fast, enabling real-time automatic labeling.

4 November 2025 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
ITIngrid Elisabeth Tveten
Ingrid Elisabeth Tveten
JNJohn Nyberg
John Nyberg
JGJahn Frederik Grue
Jahn Frederik Grue
RHRagnhild Holden Helland
Ragnhild Holden Helland
DMDaniela Melichova
Daniela Melichova
AØAndreas Østvik
Andreas Østvik
Quantitative measurements remain under-used in echocardiography due to measurement variability and time consumption. This study aimed to develop a deep learning (DL) pipeline for the automatic extraction of clinically relevant quantitative measurements from the parasternal short-axis (PSAX) view. We trained an nnU-Net model to segment the left ventricle (LV) lumen and myocardium in PSAX images. Based on end-diastole (ED) and end-systole (ES) frames in the echocardiograms, we calculated the LV lumen area, LV fractional area change, mean wall thickness (MWT) and global circumferential strain. Segmentations and measurements were validated through comparison with two manual observers. Compared with manual references, the nnU-Net model achieved a high grade of similarity for the LV lumen and myocardium, with Dice coefficients of 0.93±0.04 and 0.84±0.08, and 95th percentile Hausdorff distances of 3.2±1.9mm and 3.4±1.7mm, respectively. The Dice coefficients and 95th percentile Hausdorff distances were on par or better for the evaluation dataset. DL-based measurements were in line with interobserver precision and variability. Automatic timing of ED and ES frames based on echocardiograms and LV lumen area produced similar results to using manual timing by experts. The subject-level feasibility was 90.4%. Furthermore, DL-based measurement of MWT at ED differentiated subjects with and without hypertension (p<0.001). Our DL-based measurement pipeline for PSAX achieved performance comparable to expert annotators, positioning it as a possible substitute for tedious manual measurements. DL-derived MWT was able to differentiate hypertensive from non-hypertensive subjects, which indicates the potential clinical utility of fully automated PSAX measurements.