Here, we present a technique for the determination of the gaseous oxygen concentration inside packed food. It is based on the use of a luminescent membrane sensitive to O 2 that is optically excited and read by a smartphone. The flash of the smartphone along with an optical filter is used as the light source for the optical stimulation of the membrane. The luminescence generated, which is quenched by the surrounding gaseous oxygen, is registered by the rear camera of the same device. The response parameter is defined by combining the registered intensities at two different wavelength ranges corresponding to the emission and the absorption peaks of the sensitive membrane. Thanks to this novel response parameter, the sensitivity is increased and, more importantly, the thermal dependence of the membrane is significantly reduced. This approach allows the use of a luminescent O 2 -sensitive membrane for intelligent packaging with no need of any associated electronics for its excitation and reading. This means that an oxygen sensor is developed, where a luminescent compound acts as an indicator, therefore combining the advantages of both schemes, that is, the simplicity and reduced cost of indicators with the high sensitivity and accuracy of selective sensors.
An inkjet printed membrane is presented as a colorimetric sensor for oxygen for use in smart packaging, in order to quickly inform the consumer about possible degradation reactions in modified atmosphere products (MAP). The colorimetric sensor is based on the redox dye, toluidine blue (TB), a sacrificial electron donor, glycerol, and, hydroxypropyl methylcellulose, as the hydrophilic polymeric matrix. The UVC-wavelength activated TB is photoreduced by SnO2 nanoparticle ink. This colorimetric oxygen indicator stays colourless upon exposure in nitrogen atmosphere to 7 min UVC light (6 W·cm−2). The photoreduced TB to leuco TB recovers its original colour upon exposure to oxygen for 55 min under ambient conditions (∼21 °C, ∼55%RH, 21% O2). The characteristics of the sensor have been evaluated, including its functionality through the colorimetric response to different oxygen concentrations as well as the influence of experimental variables such as humidity and temperature using a digital camera as the detector. The results obtained show that: (1) the colorimetric sensor remains stable in the absence of oxygen; (2) relative humidity greater than 60% significantly affects the reoxidation process; and (3) the temperature has a significant influence on the colour recovery, although the stability increases considerably when the sensor is kept refrigerated at 4 °C. A real application to packaged ham was performed, demonstrating that the printed colorimetric sensor is stable for at least 48 hours once activated and when the container deteriorates upon the entrance of oxygen, the sensor returns to its original blue colour, demonstrating its utility as a UVC-activated colorimetric oxygen sensor.
16 August 2012 in Analytical and Bioanalytical Chemistry