We report a new method for the real-time quantitative analysis of sodium in human sweat, consolidating sweat collection and analysis in a single, integrated, wearable platform. This temporal data opens up new possibilities in the study of human physiology, broadly applicable from assessing high performance athletes to monitoring Cystic Fibrosis (CF) sufferers. Our compact Sodium Sensor Belt (SSB) consists of a sodium selective Ion Selective Electrode (ISE) integrated into a platform that can be interfaced with the human body during exercise. No skin cleaning regime or sweat storage technology is required as the sweat is continually wicked from the skin to a sensing surface and from there to a storage area via a fabric pump. Our results suggest that after an initial equilibration period, a steady-state sodium plateau concentration was reached. Atomic Absorption Spectroscopy (AAS) was used as a reference method, and this has confirmed the accuracy of the new continuous monitoring approach. The steady-state concentrations observed were found to fall within ranges previously found in the literature, which further validates the approach. Daily calibration repeatability (n = 4) was ±3.0% RSD and over a three month period reproducibility was ±12.1% RSD (n = 56). As a further application, we attempted to monitor the sweat of Cystic Fibrosis (CF) sufferers using the same device. We observed high sodium concentrations symptomatic of CF (∼60 mM Na+ ) for two CF patients, with no conclusive results for the remaining patients due to their limited exercising capability, and high viscosity/low volume of sweat produced.
1 August 2012 in Sensors and Actuators B: Chemical
The ability to non-invasively monitor sodium levels in sweat is of significant importance. Sodium is one of the preferred markers to diagnose and track the progression of cystic fibrosis, and knowledge of sodium levels could potentially enable personalised hydration strategies to be implemented for athletes or people working under severe environmental conditions. Herein we present a novel approach for the realisation of disposable potentiometric strips that allow for real-time monitoring of sodium in sweat. Our platform consists of a Solid-Contact Ion-Selective Electrode (SC-ISE) for Na+ detection and of a liquid-junction-free Reference Electrode (RE), combined together on a dual screen-printed substrate. Different poly-3,4-ethylenedioxythiophene (PEDOT) based films were tested as solid-contact, showing a significant impact on sensor characteristics such as sensitivity (i.e. differing from sub-Nernstian to Nernstian), dynamic range (i.e. 10−5 to 10−2.5 or 10−5 to 10−1aNa+), and especially within-batch reproducibility. The SC-ISE/RE combination was integrated into a microfluidic chip that was tested and optimised via on-bench trials. The Potentiometric Microfluidic Chip (PotMicroChip) was then connected to a wireless electronic platform to realise a wearable device whose performance was assessed during real-time stationary cycling sessions.
This study demonstrates that by combining a modified version of the Berthelot method with microfluidic technologies and LED based optical detection systems, a low cost monitoring system for detection of ammonia in fresh water and wastewater can be developed. The assay developed is a variation on the Berthelot method, eliminating several steps previously associated with the method to create a nontoxic and simple colorimetric assay. The previous Berthelot method required the addition of three reagents, mixed sequentially with the sample, which complicates the microfluidic system design. With the modified method, comparable results were attained using a single reagent addition step at a 1 : 1 v/v reagent to sample ratio, which significantly simplifies the fluidic handling requirement for integration into an autonomous sensing platform. The intense colour generated in the presence of ammonia is detected at a wavelength of 660 nm. The method allows for ammonia determination up to 12 mg L−1 NH4+ with a limit of detection of 0.015 mg L−1 NH4+. Validation was achieved by analysing split water samples by the modified method and by ion chromatography, resulting in an excellent correlation coefficient of 0.9954. The method was then implemented into a fully integrated sensing platform consisting of a sample inlet with filter, storage units for the Berthelot reagent and standards for self-calibration, pumping system which controls the transport and mixing of the sample, a microfluidic mixing and detection chip, and waste storage. The optical detection system consists of a LED light source with a photodiode detector, which enables sensitive detection of the coloured complex formed. The robustness and low cost of the microfluidic platform coupled with integrated wireless communications makes it an ideal platform for in situ environmental monitoring. This is the first demonstration of a fully functional microfluidic platform employing this modified version of the Berthelot method.
A feasibility study on a new technique capable of monitoring localized sweat rate is explored in this paper. Wearable devices commonly used in clinical practice for sweat sampling (i.e., Macroducts) were positioned on the body of an athlete whose sweat rate was then monitored during cycling sessions. The position at which the sweat fills the Macroduct was indicated by a contrasting marker and captured via a series of time-stamped photos or a video recording of the device during an exercise period. Given that the time of each captured image/frame is known (either through time stamp on photos or the constant frame rate of the video capture), it was, therefore, possible to estimate the sweat flow rate through a simple calibration model. The importance of gathering such valuable information is described, together with the results from a number of exercise trials to investigate the viability of this approach.