Arnaud Del Bello

Dr. Arnaud Del Bello

1. Department of Nephrology and Organ Transplantation, CHU de Toulouse, France
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Annals of Internal Medicine
Verified
Journal Article
Open access
OMOlivier Marion
Olivier Marion
ABArnaud Del Bello
Arnaud Del Bello
FAFlorence Abravanel
Florence Abravanel
CCChloé Couat
Chloé Couat
SFStanislas Faguer
Stanislas Faguer
Nassim KamarNassim Kamar
Nassim Kamar

31 July 2021 in American Journal of Transplantation
Verified
Journal Article
Open access
PDF file
ABArnaud Del Bello
Arnaud Del Bello
FAFlorence Abravanel
Florence Abravanel
OMOlivier Marion
Olivier Marion
CCChloé Couat
Chloé Couat
LELaure Esposito
Laure Esposito
Nassim KamarNassim Kamar
Nassim Kamar
A weak humoral response to two-doses of SARS-CoV-2 vaccine was observed in solid organ transplant (SOT) patients (1,2). Preliminary reports suggested the usefulness of a boost with a third dose (3) (4). Herein, we report the humoral response in 396 SOT patients (mean age 59 ± 15 years, 65 % men) who were given 3 doses messenger RNA-based vaccine (BNT162b2 vaccine [Pfizer-BioNTech]) (Table S1). Of these, 101 were included in our previous report (3). The two first doses were given one month apart, and the third dose was administered 59 (IQR25-75: 47-67) days after the second dose, i.e. once the third dose was recommended by the French National Authority for Health.

25 August 2015 in Transplant International
Verified
Journal Article
Open access
PDF file
ABArnaud Del Bello
Arnaud Del Bello
NCNicolas Congy-Jolivet
Nicolas Congy-Jolivet
MDMarie Danjoux
Marie Danjoux
FMFabrice Muscari
Fabrice Muscari
LLLaurence Lavayssière
Laurence Lavayssière
Nassim KamarNassim Kamar
Nassim Kamar
The incidence and consequences of de novo donor‐specific anti‐HLA antibodies (DSAs) after liver transplantation (LT) are not well known. We investigated the incidence, risk factors, and complications associated with de novo DSAs in this setting. A total of 152 de novo liver‐transplant patients, without preformed anti‐HLA DSAs, were tested for anti‐HLA antibodies, with single‐antigen bead technology, before, at transplantation, at 1, 3, 6 and 12 months after transplantation, and thereafter annually and at each time they presented with increased liver‐enzyme levels until the last follow‐up, that is, 34 (1.5–77) months. Twenty‐one patients (14%) developed de novo DSAs. Of these, five patients had C1q‐binding DSAs (24%). Younger age, low exposure to calcineurin inhibitors, and noncompliance were predictive factors for de novo DSA formation. Nine of the 21 patients (43%) with de novo DSAs experienced an acute antibody‐mediated rejection (AMR). Positive C4d staining was more frequently observed in liver biopsies of patients with AMR (9/9 vs. 1/12, P < 0.0001). Eight patients received a B‐cell targeting therapy, and one patient received polyclonal antibodies. Only one patient required retransplantation. Patient‐ and graft‐survival rates did not differ between patients with and without DSAs. In conclusion, liver‐transplant patients with liver abnormalities should be screened for DSAs and AMR.

28 April 2018 in World Journal of Gastroenterology
Verified
Journal Article
Open access
ABArnaud Del Bello
Arnaud Del Bello
NCNicolas Congy-Jolivet
Nicolas Congy-Jolivet
MDMarie Danjoux
Marie Danjoux
FMFabrice Muscari
Fabrice Muscari
LLLaurence Lavayssière
Laurence Lavayssière
Nassim KamarNassim Kamar
Nassim Kamar
High tacrolimus intra-patient variability is associated with graft rejection, and de novo donor-specific antibodies occurrence after liver transplantation

6 December 2023 in Journal of the American Society of Nephrology
Verified
Journal Article
Closed access
MRMarc Raynaud
Marc Raynaud
SASolaf Al-Awadhi
Solaf Al-Awadhi
KLKevin Louis
Kevin Louis
HZHuanxi Zhang
Huanxi Zhang
XSXiaojun Su
Xiaojun Su
ALAlexandre Loupy
Alexandre Loupy
Significance Statement: Why are there so few biomarkers accepted by health authorities and implemented in clinical practice, despite the high and growing number of biomaker studies in medical research ? In this meta-epidemiological study, including 804 studies that were critically appraised by expert reviewers, the authors have identified all prognostic kidney transplant biomarkers and showed overall suboptimal study designs, methods, results, interpretation, reproducible research standards, and transparency. The authors also demonstrated for the first time that the limited number of studies challenged the added value of their candidate biomarkers against standard-of-care routine patient monitoring parameters. Most biomarker studies tended to be single-center, retrospective studies with a small number of patients and clinical events. Less than 5% of the studies performed an external validation. The authors also showed the poor transparency reporting and identified a data beautification phenomenon. These findings suggest that there is much wasted research effort in transplant biomarker medical research and highlight the need to produce more rigorous studies so that more biomarkers may be validated and successfully implemented in clinical practice. Background: Despite the increasing number of biomarker studies published in the transplant literature over the past 20 years, demonstrations of their clinical benefit and their implementation in routine clinical practice are lacking. We hypothesized that suboptimal design, data, methodology, and reporting might contribute to this phenomenon. Methods: We formed a consortium of experts in systematic reviews, nephrologists, methodologists, and epidemiologists. A systematic literature search was performed in PubMed, Embase, Scopus, Web of Science, and Cochrane Library between January 1, 2005, and November 12, 2022 (PROSPERO ID: CRD42020154747). All English language, original studies investigating the association between a biomarker and kidney allograft outcome were included. The final set of publications was assessed by expert reviewers. After data collection, two independent reviewers randomly evaluated the inconsistencies for 30% of the references for each reviewer. If more than 5% of inconsistencies were observed for one given reviewer, a re-evaluation was conducted for all the references of the reviewer. The biomarkers were categorized according to their type and the biological milieu from which they were measured. The study characteristics related to the design, methods, results, and their interpretation were assessed, as well as reproducible research practices and transparency indicators. Results: A total of 7372 publications were screened and 804 studies met the inclusion criteria. A total of 1143 biomarkers were assessed among the included studies from blood (n=821, 71.8%), intragraft (n=169, 14.8%), or urine (n=81, 7.1%) compartments. The number of studies significantly increased, with a median, yearly number of 31.5 studies (interquartile range [IQR], 23.8–35.5) between 2005 and 2012 and 57.5 (IQR, 53.3–59.8) between 2013 and 2022 (P < 0.001). A total of 655 studies (81.5%) were retrospective, while 595 (74.0%) used data from a single center. The median number of patients included was 232 (IQR, 96–629) with a median follow-up post-transplant of 4.8 years (IQR, 3.0–6.2). Only 4.7% of studies were externally validated. A total of 346 studies (43.0%) did not adjust their biomarker for key prognostic factors, while only 3.1% of studies adjusted the biomarker for standard-of-care patient monitoring factors. Data sharing, code sharing, and registration occurred in 8.8%, 1.1%, and 4.6% of studies, respectively. A total of 158 studies (20.0%) emphasized the clinical relevance of the biomarker, despite the reported nonsignificant association of the biomarker with the outcome measure. A total of 288 studies assessed rejection as an outcome. We showed that these rejection studies shared the same characteristics as other studies. Conclusions: Biomarker studies in kidney transplantation lack validation, rigorous design and methodology, accurate interpretation, and transparency. Higher standards are needed in biomarker research to prove the clinical utility and support clinical use.

1 November 2016 in Human Immunology
Verified
Journal Article
Closed access
ABArnaud Del Bello
Arnaud Del Bello
NCNicolas Congy-Jolivet
Nicolas Congy-Jolivet
MDMarie Danjoux
Marie Danjoux
FMFabrice Muscari
Fabrice Muscari
Nassim KamarNassim Kamar
Nassim Kamar