Johan Sjöström

Dr. Johan Sjöström

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Fire Safety Journal
Verified
Journal Article
Open access
JSJohan Sjöström
Johan Sjöström
AGA. Granström
A. Granström

11 July 2019 in International Journal of Wildland Fire
Verified
Journal Article
Closed access
PDF file
JSJohan Sjöström
Johan Sjöström
FPFrida Vermina Plathner
Frida Vermina Plathner
AGAnders Granström
Anders Granström
Several large Swedish wildfires during recent decades were caused by forestry machinery in operation, fires for which there is still no characterisation. We combined 18 years of data on dispatches, weather and fire danger and interviewed forestry workers to understand the spatial, temporal and weather distributions of these fires, and their underlying mechanisms. We estimate the average annual number of ignitions from forestry machinery in Sweden at 330–480 (2.0 ± 0.4 ignitions per 1000 ha clear-felling) of which 34.5 led to firefighter dispatches, constituting 2.2% of all forest fire dispatches and 40% of area burnt. Soil scarification causes the most ignitions and the main mechanism is likely high-inertia contact between discs and large stones, causing sparks igniting dry humus or moss, countering reports suggesting that such metal fragments cannot fulfil ignition requirements. We found a spatial relationship between forestry machine ignitions and abundance of large stones, represented by a Boulder Index generated from a nationwide dataset. Further, 75% of the dispatches occurred on days with relative humidity 26 and Fire Weather Index >12. 75% of the area burned when Fire Weather Index was >20. Results suggest machine-caused forest fires can be largely avoided by cancelling operations in stony terrain during high-risk weather.

17 November 2020 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
Johan AndersonJohan Anderson
Johan Anderson
JSJohan Sjöström
Johan Sjöström
ATAlastair Temple
Alastair Temple
MCMarion Charlier
Marion Charlier
XDXu Dai
Xu Dai
DRDAvid Rush
DAvid Rush

8 July 2021 in Fire and Materials
Verified
Journal Article
Open access
PDF file
RMRobert McNamee
Robert McNamee
JSJohan Sjöström
Johan Sjöström
LBLars Boström
Lars Boström
Summary: The addition of polypropylene (PP) fibres has been shown to reduce the fire spalling propensity of concrete. When including this type of fibres in the concrete, the concrete mix becomes less robust, and small deviations in the constitutes change the workability and properties of the concrete. So, from a manufacturing perspective as small dosages as possible of PP fibres are desirable. Very few large‐scale fire resistance tests of concrete loaded in compression exist showing the function of PP fibres at low dosages on concrete mixes sensitive to spalling if no fibres are added. In this paper, results from 26 fire tests are presented and analysed. The test results are from four different experimental campaigns, but all the mixes have in common that the water‐to‐cement ratio is 0.40. The results show that an amount of only 0.6 kg/m3 PP fibres has a significant effect on the spalling propensity and that even lower amounts reduce the spalling although they do not eliminate it entirely. During one of the fire tests on large slabs loaded in compression, unloaded small cubes of the same mixes were also included in the furnace. None of the small specimens spalled, whereas some of the corresponding large slabs spalled beyond the layer of reinforcement. This illustrates that tests on small, unloaded specimens are not relevant when assessing fire spalling of larger cross‐sections loaded in compression.

31 July 2023 in International Journal of Wildland Fire
Verified
Journal Article
Open access
PDF file
JSJohan Sjöström
Johan Sjöström
AGAnders Granström
Anders Granström
Background: Directly after snowmelt, northern grasslands typically have highly flammable fuel-beds consisting of 100% grass litter. With green-up, the addition of high-moisture foliage leads to progressively decreasing fire hazard. Aims: Our aim was to create a fire-danger index for northern grasslands that incorporated grass phenology. Methods: We made use of 25 years of Swedish wildfire data and 56 experimental fires conducted during one full fire-season, merged with established models for moisture content and flame spread rates. Refined data on equilibrium moisture content of grass litter were obtained through laboratory tests. Key results: The RING (Rate of spread In Northern Grasslands) model uses cumulative air temperature as a proxy for growing season progression. Three independent functions account for impact of wind, moisture content and the damping effect of live grass, respectively. The latter results in exponentially decaying rate of spread (ROS) with the progressing season. Following the field experiments, green grass proportion as low as 10–20% (live/dead dry-mass) resulted in model-ROS so reduced that the grassland fire season could effectively be considered over. Conclusions: The model, calculated from standard meteorological data only, matches the experimental results and separately performed validation tests, as well as wildfire dispatch data. Implications: RING has been used in Sweden since 2021 and is likely applicable to other northern regions as well.

20 August 2022 in Fire
Verified
Journal Article
Open access
PDF file
DHDaniel Honfi
Daniel Honfi
JSJohan Sjöström
Johan Sjöström
Chiara BedonChiara Bedon
Chiara Bedon
Marcin KozłowskiMarcin Kozłowski
Marcin Kozłowski
Despite much research and applications, glass material and its use in buildings is still challenging for engineers due to its inherent brittleness and characteristic features such as sensitivity to stress concentrations, reduction in strength over time and from temperature, and breakage due to the stresses that may build up because of thermal gradients. This paper presents the results of an original test series carried out on monolithic glass panes with the dimensions of 500 × 500 mm2 and different thicknesses, under the exposure to radiant heating. The research study also includes a one-dimensional (1D) heat transfer model and a numerical, three-dimensional (3D) thermo-mechanical model that are used to investigate in greater detail the phenomena observed during the experiments. As shown, the behaviour of glass under radiant heating is rather complex and confirms the high vulnerability of this material for building applications. The usability and potential of thermo-mechanical numerical models is discussed towards experimental feedback.