Marion Charlier

Ms. Marion Charlier

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2022 in Fire Safety Journal
Verified
Journal Article
Closed access
ANAli Nadjai
Ali Nadjai
Naveed AlamNaveed Alam
Naveed Alam
MCMarion Charlier
Marion Charlier
OVOlivier Vassart
Olivier Vassart
SWStephen Welch
Stephen Welch
JSJohan Sjostrom
Johan Sjostrom

22 December 2023 in Modelling
Verified
Journal Article
Open access
PDF file
JFJosé Humberto Matias de Paula Filho
José Humberto Matias de Paula Filho
Marina D'AntimoMarina D'Antimo
Marina D'Antimo
MCMarion Charlier
Marion Charlier
OVOlivier Vassart
Olivier Vassart
In 2020, 37% of global CO2eq. emissions were attributed to the construction sector. The major effort to reduce this share of emissions has been focused on reducing the operational carbon of buildings. Recently, awareness has also been raised on the role of embodied carbon: emissions from materials and construction processes must be urgently addressed to ensure sustainable buildings. To assess the embodied carbon of a building, a life-cycle assessment (LCA) can be performed; this is a science-based and standardized methodology for quantifying the environmental impacts of a building during its life. This paper presents the comparative results of a “cradle-to-cradle” building LCA of an office building located in Luxembourg with 50 years of service life. Three equivalent structural systems are compared: a steel–concrete composite frame, a prefabricated reinforced concrete frame, and a timber frame. A life-cycle inventory (LCI) was performed using environmental product declarations (EPDs) according to EN 15804. For the considered office building, the steel–concrete composite solution outperforms the prefabricated concrete frame in terms of global warming potential (GWP). Additionally, it provides a lower GWP than the timber-frame solution when a landfill end-of-life (EOL) scenario for wood is considered. Finally, the steel–concrete composite and timber solutions show equivalent GWPs when the wood EOL is assumed to be 100% incinerated with energy recovery.

17 November 2020 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
Johan AndersonJohan Anderson
Johan Anderson
JSJohan Sjöström
Johan Sjöström
ATAlastair Temple
Alastair Temple
MCMarion Charlier
Marion Charlier
XDXu Dai
Xu Dai
DRDAvid Rush
DAvid Rush

6 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MCMarion Charlier
Marion Charlier
JFJean-Marc Franssen
Jean-Marc Franssen
FDFabien Dumont
Fabien Dumont
ANAli Nadjai
Ali Nadjai
OVOlivier Vassart
Olivier Vassart
The term “travelling fire” is used to label fires which burn locally and move across the floor over a period of time in large compartments. Through experimental and numerical campaigns and while observing the tragic travelling fire events, it became clear that such fires imply a transient heating of the surrounding structure. The necessity to better characterize the thermal impact generated on the structure by a travelling fire motivated the development of an analytical model allowing to capture, in a simple manner, the multidimensional transient heating of a structure considering the effect of the ventilation. This paper first presents the basic assumptions of a new analytical model which is based on the virtual solid flame concept; a comparison of the steel temperatures measured during a travelling fire test in a steel-framed building with the ones obtained analytically is then presented. The limitations inherent to the analyticity of the model are also discussed. This paper suggests that the developed analytical model can allow for both an acceptable representation of the travelling fire in terms of fire spread and steel temperatures while not being computationally demanding, making it potentially desirable for pre-design.

1 September 2021 in Proceedings of the Institution of Civil Engineers - Structures and Buildings
Verified
Journal Article
Closed access
MCMarion Charlier
Marion Charlier
AGAntonio Gamba
Antonio Gamba
XDXu Dai
Xu Dai
SWStephen Welch
Stephen Welch
OVOlivier Vassart
Olivier Vassart
JFJean-Marc Franssen
Jean-Marc Franssen
The response of structures exposed to fire is highly dependent on the type of fire that occurs, which is in turn very dependent on the compartment geometry. In a European research project, computational fluid dynamics simulations were carried out to analyse the influence of compartment geometry and the interaction with representative fuel loads to explore the conditions leading to the development of a travelling fire. The influence observed of ceiling height, crib spacing and opening geometry in controlling spread rates tended to confirm the possibility of predicting the occurrence, or not, of a travelling fire. The results of one analysis were then used to perform a non-linear thermo-mechanical analysis of a steel structure. It was possible to use the radiative intensities and gas temperatures obtained with a computational fluid dynamics model to calculate with a finite-element model the temperatures in structural elements located in the compartment, and to evaluate the structural behaviour of a frame made of these elements. This paper therefore highlights the effect of building design specifications on the temperature development and on the resulting mechanical behaviour of a steel structure where the travelling nature of a fire has been considered comprehensively.

13 May 2022 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
ANAli Nadjai
Ali Nadjai
Naveed AlamNaveed Alam
Naveed Alam
MCMarion Charlier
Marion Charlier
OVOlivier Vassart
Olivier Vassart
XDXu Dai
Xu Dai
JSJohan Sjostrom
Johan Sjostrom
Purpose: In the frame of the European RFCS TRAFIR project, three large compartment fire tests involving steel structure were conducted by Ulster University, aiming at understanding in which conditions a travelling fire develops, as well as how it behaves and impacts the surrounding structure.Design/methodology/approach: During the experimental programme, the path and geometry of the travelling fire was studied and temperatures, heat fluxes and spread rates were measured. Influence of the travelling fire on the structural elements was also monitored during the travelling fire tests.Findings: This paper provides details related to the influence of travelling fires on a central structural steel column.Originality/value: The experimental data are presented in terms of the gas temperatures recorded in the test compartment near the column, as well as the temperatures recorded in the steel column at different levels. Because of the large data, only fire test one results are discussed in this paper.