Filomena Maietta

Ms. Filomena Maietta

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2022 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
Bruno BrunoneBruno Brunone
Bruno Brunone
FMFilomena Maietta
Filomena Maietta
Caterina CapponiCaterina Capponi
Caterina Capponi
AKAlireza Keramat
Alireza Keramat
Silvia MeniconiSilvia Meniconi
Silvia Meniconi
Since the 1990s, pressure waves propagating in pressurized pipes during a transient event have been re-evaluated both in the laboratory and in real systems as a way to obtain information about location and size of leaks. However, a systematic analysis of the obtained results has not been offered yet in the literature. In this paper, a review of the available experimental data concerning the use of transient tests for leak identification in pressurized pipe systems is presented. The selected data are examined with regard to the main features (categories) influencing the transient response of a leaky pipe system: layout, modality of transient generation, material, diameter, pre-transient pressure and flow condition, inserted pressure wave, and leak characteristics. Moreover, for each of such categories, possible specific issues to address for future research are proposed.

3 January 2023 in Fluids
Verified
Journal Article
Open access
PDF file
Bruno BrunoneBruno Brunone
Bruno Brunone
FMFilomena Maietta
Filomena Maietta
Caterina CapponiCaterina Capponi
Caterina Capponi
HDHF Duan
HF Duan
Silvia MeniconiSilvia Meniconi
Silvia Meniconi
Pressure waves, while traveling along pressurized pipes, collect precious information about possible faults (e.g., leaks and partial blockages). In fact, the characteristics of the pressure wave reflected by the fault are strongly related to it. To encourage the use of the transient test-based technologies (TTBTs) for partial blockage (PB) detection in pressurized pipe systems, it can be of interest to critically analyze the available experimental results and to point out the aspects that need to be investigated in more detail, since no review has been executed so far. Such a deficiency has two negative consequences. The first one is that TTBTs are still relegated to limbo by technicians. The second one is that not enough material is available for refining tools to extract all the information contained in the acquired pressure signals and then to pursue an effective PB detection. As main results of the executed analysis, the following issues can be counted: (i) the lack of tests carried out in large diameter and concrete pipes; (ii) the absence of tests carried out in complex pipe systems (e.g., looped networks); and (iii) the extreme need for considering real pipe systems. The fulfillment of the last issue will greatly contribute to the solutions of the other ones.

29 September 2022 in Water Resources Research
Verified
Journal Article
Open access
Silvia MeniconiSilvia Meniconi
Silvia Meniconi
FMFilomena Maietta
Filomena Maietta
Stefano AlvisiStefano Alvisi
Stefano Alvisi
Caterina CapponiCaterina Capponi
Caterina Capponi
Valentina MarsiliValentina Marsili
Valentina Marsili
Bruno BrunoneBruno Brunone
Bruno Brunone
At the Water Engineering Laboratory of the University of Perugia, Italy, a wide experimental program has been carried out in a polymeric pipe network with two 100 × 100 m square loops. The aim of this program is to analyze the dynamic response of the system to transients caused by a change in water consumption. To emphasize such a response, transients are generated by the complete and fast closure of an end‐user, located at the downstream end of a service line. During tests, the combined effect of simultaneous consumers, whose consumption is varied both deterministically and stochastically, has been analyzed. The tests allow examining the propagation of the generated pressure waves within the network for different water consumption variations and end‐user locations. The lessons learnt from the experimental results may help the water utility managers to identify the reasons for the higher frequency of occurrence and severity of faults in some specific portions of water distribution networks apparently “similar” to others where damages are less frequent and severe.

8 November 2023 in AQUA — Water Infrastructure, Ecosystems and Society
Verified
Journal Article
Open access
PDF file
Valentina MarsiliValentina Marsili
Valentina Marsili
Filippo MazzoniFilippo Mazzoni
Filippo Mazzoni
Stefano AlvisiStefano Alvisi
Stefano Alvisi
FMFilomena Maietta
Filomena Maietta
Caterina CapponiCaterina Capponi
Caterina Capponi
Marco FranchiniMarco Franchini
Marco Franchini
Recent studies point out that water distribution networks can be affected by long- and short-term pressure oscillations due to the users' activity. However, these transients, generated at the household level, before reaching the water distribution network pass through, and thus affect, the water service line and can contribute to its deterioration. Despite the role of user-induced transients in stressing service lines, few studies in the literature explored the topic, exclusively by means of laboratory tests. The current study is aimed at exploring the effects of user's activity on a real service line starting from the field monitoring of pressure data at 500-Hz temporal resolution. Pressure signals are collected both when activating single water devices of the user supplied by the service line and during the ordinary use of domestic devices. The analyses of the acquired data highlight that the domestic service line is subjected to significant pressure variations (which can reach extreme values of −15 and +65 m) based on the device type and distance between the device and the service line and that the use of these devices can continuously stress the water service line.

8 August 2023 in Water Resources Research
Verified
Journal Article
Open access
Valentina MarsiliValentina Marsili
Valentina Marsili
Stefano AlvisiStefano Alvisi
Stefano Alvisi
FMFilomena Maietta
Filomena Maietta
Caterina CapponiCaterina Capponi
Caterina Capponi
Silvia MeniconiSilvia Meniconi
Silvia Meniconi
Marco FranchiniMarco Franchini
Marco Franchini
Water distribution networks (WDNs) are complex combinations of nodes and links, and the current tendency is to modify their topological structure through the closure of isolation valves for monitoring and water quality reasons. For their analysis, several approaches based on graph theory have recently been proposed, mainly considering steady‐state flow conditions. However, in their real functioning, WDNs are continuously subjected to pressure transients generated by maneuvers on regulation devices or by users' activity. This study investigates the application of some metrics from graph theory, already used in the context of steady‐state analysis, for assessing the effects of changes in the topological structure of a network—due for example, to sectorization or branching operations—on its transient response when subjected to maneuvers on devices such as hydrants, pumps, etc. or users' activity. The analysis shows that some connectivity metrics can effectively reflect the dynamic pressure behavior of the network and, thus, provide useful indications for design and management operations taking into account unsteady flow features.

2 September 2022 in Water
Verified
Journal Article
Open access
PDF file
Silvia MeniconiSilvia Meniconi
Silvia Meniconi
FMFilomena Maietta
Filomena Maietta
Stefano AlvisiStefano Alvisi
Stefano Alvisi
Caterina CapponiCaterina Capponi
Caterina Capponi
Valentina MarsiliValentina Marsili
Valentina Marsili
Bruno BrunoneBruno Brunone
Bruno Brunone
This paper analyses the propagation and mechanisms of interaction of a pressure wave in a looped water distribution network by means of laboratory and numerical tests. Transients are generated by the complete and fast closure of a valve, simulating an end-user maneuver, located at the downstream end section of a service line. The adequate length of the service line allows capturing each single pressure wave inserted into the network. The executed tests and successive analysis by means of a Lagrangian model (LM) highlight the effect of the network topology and the location of the transient generation point but in a more expeditious way with respect to the use of a complete transient model. The most excited part of the system is the one in close proximity of the end-user and then the corresponding service line. Within the network, pressure waves accumulate in the areas with the smallest diameter pipes. By means of the refined LM—which is able to capture the pressure extreme values occurring in the first phases of the transient—the vulnerability maps of the network are provided. Such maps identify the nodes subjected to the most severe pressure waves in terms of both frequency and amplitude. The exposure level to transients of each node is synthesized by the value of the vulnerability index proposed in this paper.