Francesco Romano

Dr. Francesco Romano

Italian National Institute of Nuclear Physics (INFN), Catania Division, Via S. Sofia 64, 95123 Catania, Italy

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2022 in Medical Physics
Verified
Journal Article
Open access
FRFrancesco Romano
Francesco Romano
CBClaude Bailat
Claude Bailat
PJPatrik Gonçalves Jorge
Patrik Gonçalves Jorge
MLMichael Lloyd Franz Lerch
Michael Lloyd Franz Lerch
ADArash Darafsheh
Arash Darafsheh
The clinical translation of FLASH radiotherapy (RT) requires challenges related to dosimetry and beam monitoring of ultra‐high dose rate (UHDR) beams to be addressed. Detectors currently in use suffer from saturation effects under UHDR regimes, requiring the introduction of correction factors. There is significant interest from the scientific community to identify the most reliable solutions and suitable experimental approaches for UHDR dosimetry. This interest is manifested through the increasing number of national and international projects recently proposed concerning UHDR dosimetry. Attaining the desired solutions and approaches requires further optimization of already established technologies as well as the investigation of novel radiation detection and dosimetry methods. New knowledge will also emerge to fill the gap in terms of validated protocols, assessing new dosimetric procedures and standardized methods. In this paper, we discuss the main challenges coming from the peculiar beam parameters characterizing UHDR beams for FLASH RT. These challenges vary considerably depending on the accelerator type and technique used to produce the relevant UHDR radiation environment. We also introduce some general considerations on how the different time structure in the production of the radiation beams, as well as the dose and dose‐rate per pulse, can affect the detector response. Finally, we discuss the requirements that must characterize any proposed dosimeters for use in UDHR radiation environments. A detailed status of the current technology is provided, with the aim of discussing the detector features and their performance characteristics and/or limitations in UHDR regimes. We report on further developments for established detectors and novel approaches currently under investigation with a view to predict future directions in terms of dosimetry approaches, practical procedures, and protocols. Due to several on‐going detector and dosimetry developments associated with UHDR radiation environment for FLASH RT it is not possible to provide a simple list of recommendations for the most suitable detectors for FLASH RT dosimetry. However, this article does provide the reader with a detailed description of the most up‐to‐date dosimetric approaches, and describes the behavior of the detectors operated under UHDR irradiation conditions and offers expert discussion on the current challenges which we believe are important and still need to be addressed in the clinical translation of FLASH RT.

1 August 2023 in British Journal of Radiology
Verified
Journal Article
Open access
ASAnna Subiel
Anna Subiel
FRFrancesco Romano
Francesco Romano
Ultra-high dose-rate (UHDR) irradiations, known as FLASH radiotherapy (RT), rely on delivery of therapeutic doses at instantaneous dose-rates several orders of magnitude higher than those currently used in conventional radiotherapy. It has been shown that such an extremely short delivery of radiation leads to remarkable reduction of normal tissue toxicity with respect to conventional dose-rate RT. However, dosimetry at UHDRs is complicated and it is essential to understand the effects that will influence detector response. To date, FLASH RT research has been focused on finding pragmatic solutions that allow the use of UHDR beams in the research setting, but there has been limited focus on absolute dosimetry utilizing primary and secondary standard devices. However, very recently, the data on existing standard dosimeters and novel solutions which could serve as secondary standard devices in UHDR dosimetry started emerging. This review provides an overview of the studies that have been conducted employing calorimeters and innovative solutions utilizing ionization chambers.

25 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FRFrancesco Romano
Francesco Romano
GMGiuliana Milluzzo
Giuliana Milluzzo
FMfabio di martino
fabio di martino
MDMaria Cristina D'Oca
Maria Cristina D'Oca
GFGiuseppe Felici
Giuseppe Felici
Massimo CamardaMassimo Camarda
Massimo Camarda
Ultra-high dose rate (UHDR) beams for FLASH radiotherapy present significant dosimetric challenges. Although novel approaches for decreasing or correcting ion recombination in ionization chambers are being proposed, applicability of ionimetric dosimetry to UHDR beams is still under investigation. Solid-state sensors have been recently investigated as a valuable alternative for real-time measurements, especially for relative dosimetry and beam monitoring. Among them, Silicon Carbide (SiC) represents a very promising candidate, compromising between the maturity of Silicon and the robustness of diamond. Its features allow for large area sensors and high electric fields, required to avoid ion recombination in UHDR beams. In this study, we present simulations and experimental measurements with the low energy UHDR electron beams accelerated with the ElectronFLASH machine developed by the SIT Sordina company (IT). The response of a newly developed 1 × 1 cm2 SiC sensor in charge as a function of the dose-per-pulse and its radiation hardness up to a total delivered dose of 90 kGy, was investigated during a dedicated experimental campaign, which is, to our knowledge, the first characterization ever done of SiC with UHDR-pulsed beams accelerated by a dedicated ElectronFLASH LINAC. Results are encouraging and show a linear response of the SiC detector up to 2 Gy/pulse and a variation in the charge per pulse measured for a cumulative delivered dose of 90 kGy, within ±0.75%.

9 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
EMElisabetta Medina
Elisabetta Medina
ESEnrico Sangregorio
Enrico Sangregorio
ACAndreo Crnjac
Andreo Crnjac
FRFrancesco Romano
Francesco Romano
GMGiuliana Milluzzo
Giuliana Milluzzo
Massimo CamardaMassimo Camarda
Massimo Camarda
Silicon carbide (SiC), thanks to its material properties similar to diamond and its industrial maturity close to silicon, represents an ideal candidate for several harsh-environment sensing applications, where sensors must withstand high particle irradiation and/or high operational temperatures. In this study, to explore the radiation tolerance of SiC sensors to multiple damaging processes, both at room and high temperature, we used the Ion Microprobe Chamber installed at the Ruđer Bošković Institute (Zagreb, Croatia), which made it possible to expose small areas within the same device to different ion beams, thus evaluating and comparing effects within a single device. The sensors tested, developed jointly by STLab and SenSiC, are PIN diodes with ultrathin free-standing membranes, realized by means of a recently developed doping-selective electrochemical etching. In this work, we report on the changes of the charge transport properties, specifically in terms of the charge collection efficiency (CCE), with respect to multiple localized proton irradiations, performed at both room temperature (RT) and 500 °C.

16 November 2023 in Frontiers in Physics
Verified
Journal Article
Open access
JPJake Harold Pensavalle
Jake Harold Pensavalle
FRFrancesco Romano
Francesco Romano
MCMariagrazia Celentano
Mariagrazia Celentano
DSDamiano Del Sarto
Damiano Del Sarto
GFGiuseppe Felici
Giuseppe Felici
FMFabio Di Martino
Fabio Di Martino
The use of the flash effect and mini-beams have demonstrated the ability to spare healthy tissue while maintaining the same effectiveness in controlling tumors. In this study, we present the implementation and comprehensive dosimetric characterization of low-energy mini-beam radiation therapy at both conventional and ultra-high dose rates. These beams possess important features that allow for a wide range of spatial and temporal parameter variations, independently or simultaneously, for both effects. This novel capability enables the performance of in vivo/vitro radiobiological experiments, which are crucial for understanding the underlying mechanisms and quantitative dependencies of these effects on their respective parameters. This understanding is essential for evaluating the potential clinical applications of the two effects both individually and in terms of their potential synergistic actions.

1 January 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
GTGabriele Trovato
Gabriele Trovato
MNMarzio De Napoli
Marzio De Napoli
CGChristian Gollwitzer
Christian Gollwitzer
SFSimone Finizio
Simone Finizio
MKMichael Krumrey
Michael Krumrey
Massimo CamardaMassimo Camarda
Massimo Camarda
For many synchrotron radiation experiments, it is critical to perform continuous, real-time monitoring of the X-ray flux for normalization and stabilization purposes. Traditional transmission-mode monitors included metal mesh foils and ionization chambers, which suffered from low signal stability and size constraints. Solid-state detectors are now considered superior alternatives for many applications, offering appealing features like compactness and signal stability. However, silicon-based detectors suffer from poor radiation resistance, and diamond detectors are limited in scalability and are expensive to produce. Silicon carbide (SiC) has recently emerged as an alternative to both materials, offering a high-quality mature semiconductor with high thermal conductivity and radiation hardness. This study focuses on a systematic exploration of the SiC `free-standing membrane' devices developed by SenSiC GmbH. In particular, we performed in-depth sensor-response analysis with photon energies ranging from tender (1.75 keV) to hard (10 keV) X-rays at the Four-Crystal Monochromator beamline in the PTB laboratory at the synchrotron radiation facility BESSY II, studying uniformity of transmission and responsivity compared with the state-of-the-art beam monitors. Furthermore, we theoretically evaluated the expected signal in different regions of the sensors, also taking into account the effect of charge diffusion from the SiC substrate in the case of the not-carved region.