Piotr Lipiec

Dr. Piotr Lipiec

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2008 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
PLPiotr Lipiec
Piotr Lipiec
MKMaria Krzemińska-Pakuła
Maria Krzemińska-Pakuła
MPMichał Plewka
Michał Plewka
JKJacek Kuśmierek
Jacek Kuśmierek
APAnna Płachcińska
Anna Płachcińska
JKJarosław D. Kasprzak
Jarosław D. Kasprzak

1 August 2008 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
PLPiotr Lipiec
Piotr Lipiec
PWPaulina Wejner-Mik
Paulina Wejner-Mik
MKMaria Krzemińska-Pakuła
Maria Krzemińska-Pakuła
JKJacek Kuśmierek
Jacek Kuśmierek
APAnna Płachcińska
Anna Płachcińska
JKJarosław D. Kasprzak
Jarosław D. Kasprzak

25 September 2018 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
MSMaria Chiara Scali
Maria Chiara Scali
QCQuirino Ciampi
Quirino Ciampi
EPEugenio Picano
Eugenio Picano
EBEduardo Bossone
Eduardo Bossone
FFFrancesco Ferrara
Francesco Ferrara
CCClara Carpeggiani
Clara Carpeggiani
The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. To provide web-based upstream quality control and harmonization of B-lines reading criteria. 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.

16 February 2018 in Polish Heart Journal
Verified
Journal Article
Closed access
PDF file
PLPiotr Lipiec
Piotr Lipiec
JBJanusz Bąk
Janusz Bąk
WBWojciech Braksator
Wojciech Braksator
MFMarcin Fijałkowski
Marcin Fijałkowski
AGAndrzej Gackowski
Andrzej Gackowski
PHPiotr Hoffman
Piotr Hoffman
This document presents current Polish guidelines on the clinical use of transthoracic echocardiography, including stress examinations, in adult patients. The examinations with pocket-size imaging devices are also discussed. The authors present recommendations regarding indications and contraindications, staff and equipment requirements, patient preparation and information, examination protocol, reporting and reimbursement. This document presents current Polish guidelines on the clinical use of transthoracic echocardiography, including stress examinations, in adult patients. The examinations with pocket-size imaging devices are also discussed. The authors present recommendations regarding indications and contraindications, staff and equipment requirements, patient preparation and information, examination protocol, reporting and reimbursement.

1 January 2010
Verified
Journal Article
Closed access
RKRadosław Kręcki
Radosław Kręcki
MKMaria Krzemińska-Pakuła
Maria Krzemińska-Pakuła
JDJarosław Drożdż
Jarosław Drożdż
PSPiotr Szcześniak
Piotr Szcześniak
JPJan Zbigniew Peruga
Jan Zbigniew Peruga
Jaroslaw Damian KasprzakJaroslaw Damian Kasprzak
Jaroslaw Damian Kasprzak

Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
MBMichał Błaszczyk
Michał Błaszczyk
KCKamila Cygulska
Kamila Cygulska
KFKrzysztof Filipczak
Krzysztof Filipczak
ZAZbigniew Adamczewski
Zbigniew Adamczewski
APAnna Płachcińska
Anna Płachcińska
Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, study processing is not free from subjective factors. Therefore, this paper aims to evaluate intra- and interobserver repeatability of MBF and MFR values obtained by the same operator and two independent operators. Methods: This study included 57 adult patients. MBF and MFR were assessed using a Discovery NM530c camera in a two-day, rest/dipyridamople protocol, using 99mTc-MIBI. Data were processed using Corridor4DM software, twice by one operator and once by another operator. Results: The repeatability of the assessed values was quite good in the whole myocardium, LAD and LCX vascular territories, but was poor in the RCA territory. Conclusions: The poor repeatability of MBF and MFR in RCA vascular territory can be explained by poor automatic orientation of the heart axis during post-processing and a so-called “cardiac creep” phenomenon. Better automatic heart orientation and introduction of automatic motion correction is likely to drastically improve this repeatability. In the present state of the software, PET is better for patients requiring assessment of MFR in the RCA territory.