Nehal نهال مجدي Ayash

Dr. Nehal نهال مجدي Ayash

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Structures
Verified
Journal Article
Closed access
Nehal نهال مجدي AyashNehal نهال مجدي Ayash
Nehal نهال مجدي Ayash
AAAhmed M. Abd-Elrahman
Ahmed M. Abd-Elrahman
ASAbd-Elaziz Soliman
Abd-Elaziz Soliman

28 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HEHala Mamdouh Esmael
Hala Mamdouh Esmael
Ashraf M.AliAshraf M.Ali
Ashraf M.Ali
MOMostafa A. Osman
Mostafa A. Osman
Ahmed Mohamed HassanAhmed Mohamed Hassan
Ahmed Mohamed Hassan
Nehal نهال مجدي AyashNehal نهال مجدي Ayash
Nehal نهال مجدي Ayash
With the rise in cement production required by conventional concrete, CO2 emissions increase, causing pollution to the atmosphere. Geopolymer concrete (GPC) is investigated in the literature as an eco-efficient alternative to conventional concrete (CC). However, most geopolymer studies focus on studying the mechanical properties of GPC, with only limited investigations on the structural performances of structural elements using GPC. The structural behaviors of GPC elements are yet to be completely understood, and there are no current studies on investigating the structural behaviors of geopolymer slag concrete. Thus, this paper investigates the flexural performances of reinforced geopolymer slag concrete beams, focusing on the effects of different beam depths and reinforcement ratios. Five full-scale ambient-cured reinforced geopolymer slag concrete beams were tested under four-point flexure, in addition to one control conventional concrete (CC) beam. The structural performances are evaluated, including the cracking moment, flexural capacity, load–deflection relationship, and crack distribution. The results indicate that the flexural behaviors of GPC beams are comparable to that of the CC beams. Compared to the CC beams, the GPC beams have 7.4% higher flexural moment capacity, 60% lower stiffness, 28% lower ductility, and 18.3% higher toughness. Finally, the Egyptian code of practice ECP 203 and ACI 318 are found to be applicable to safely design under-reinforced GPC flexural beam elements.

28 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
FSFattouh M. F. Shaker
Fattouh M. F. Shaker
MDMohammed Said Daif
Mohammed Said Daif
Ahmed Mohamed HassanAhmed Mohamed Hassan
Ahmed Mohamed Hassan
Nehal نهال مجدي AyashNehal نهال مجدي Ayash
Nehal نهال مجدي Ayash
Concrete-filled steel tube (CFST) columns are used in tall buildings and bridges, and they provide more rigidity and higher bearing capacity, but buckling affects their behavior. There is an exceptional need to study the behavior of these columns under various conditions. The numerical method is beneficial in supplementing the experimental works and is used to explore the effects of various parameters because of the limitations in cost, apparatus, and time of the experimental program. The various parameters, such as the different slenderness ratios, i.e., column-height-to-cross-section-dimension (H/D), different steel-tube-thickness-to-column-dimension (D/t), and different compressive strength of concrete to yield strength of steel tube ratio (fc/fy) under concentric axial loading are considered in this current study. Firstly, a finite element model used the “ANSYS” software program and was constructed to validate the results of the experimental works. The extensive numerical models were carried out to extensively widen the study in this field. The numerical work was conducted on sixty-four specimens. Moreover, the analytical calculations from the different international codes/standards were compared with the numerical results to test their reliability in predicting the ultimate carrying loads. The study provided results that show the improvement effect of CFST columns with the high compressive strength of infilled concrete, while no remarkable enhancement effect with the high yield strength of steel tube was observed. Increasing the columns’ diameter is more effective in enhancing the load capacity (about three times more) than increasing the tube thickness (about 1.3 times). Ring stiffeners for long CFST columns (H/D > 12) do not lead to any enhancement of the column behavior due to yielding occurring firstly at the location of the rings. ECP205-2007 is the most conservative design code in predicting the load capacity of CFST columns, while the AIJ design code is good at predicting the ultimate load failure compared to the other codes/standards. Eurocode 4 provides underestimation values of the load-carrying capacity of CFST columns.

8 April 2025 in Structures
Verified
Journal Article
Closed access
AAAhmed H. Ali
Ahmed H. Ali
HEHala Mamdouh Esmael
Hala Mamdouh Esmael
KMKareem A. M
Kareem A. M
Nehal نهال مجدي AyashNehal نهال مجدي Ayash
Nehal نهال مجدي Ayash

28 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LALoai Alkhattabi
Loai Alkhattabi
Nehal نهال مجدي AyashNehal نهال مجدي Ayash
Nehal نهال مجدي Ayash
MHMohamed Hassan
Mohamed Hassan
ASAhmed Sayed
Ahmed Sayed
This article explores the punching shear behavior of GFRP-RC interior slab–column connections. The parameters tested included the column–aspect ratio (1.0, 2.0, 3.0, 4.0, and 5.0), perimeter-to-depth ratio for square column stubs with side lengths of 0.3, 0.4, 0.5, 0.6, and 0.7 m, and span-to-depth ratios of 4, 6, 8, 10, and 12. A review of the literature revealed that no previous study has investigated the effect of these parameters or their interactions on this type of connection. Numerically, twenty-five slabs were created using finite element (FE) software (V3), each with square dimensions of 2.5 m and a constant thickness of 0.2 m. The central column extended 0.3 m from the top and bottom of the slab. All four sides of the slabs were supported, and the specimens underwent pure static shear load testing. The test results demonstrated that all slabs failed due to punching shear. Increasing any parameter value reduced the punching shear stresses. Additionally, the results indicated that Canadian (CSA-S806-12) and Japanese (JSCE-97) standards for FRP-RC materials generally provided the closest predictions of punching shear capacity compared to the American guideline, ACI 440.1R-22. However, all standards exhibited shortcomings and require enhancement and modifications, particularly to consider the impact of the span-to-depth ratio. Therefore, three equations were developed to predict the shear strength of the connections, yielding better results than those prescribed by the North American and Japanese standards.

1 December 2024 in Engineering Research Journal
Verified
Journal Article
Open access
PDF file
Nehal نهال مجدي AyashNehal نهال مجدي Ayash
Nehal نهال مجدي Ayash
FSFattouh Mohammed Fattouh Shaker
Fattouh Mohammed Fattouh Shaker
FMFatma Abdelmohsen Mahmoud
Fatma Abdelmohsen Mahmoud
Several structures have employed steel plate shear walls (SPSWs). It might cause excessive lateral drift and substantial seismic demands on vertical boundary elements (VBEs). A sensible workaround for SPSW systems is to install an outrigger as a dissipated system in place of the adjacent bay of the SPSWs. This will disperse some of the overturning forces to the adjacent columns, thereby reducing lateral drifts and seismic demand on the VBEs. Nonlinear time history studies are performed for 12- and 20-story free-standing SPSWs with different wall bay width-to-depth ratios and SPSWs combined with Buckling restrained brace outrigger (BRB-O). The effectiveness of the BRB-O on the overall seismic behavior is investigated. These elements are placed in single and double BRB-Os at various locations along the wall. The findings indicated that adding BRB-O significantly reduces lateral responses. Positioning a single BRB-O in the stories near the middle height of the SPSW or above (especially at ¾ of the structure's height from the base) will improve its stiffness more than that placed in the below stories. The most effective way to position the double BRB-Os is to place one at the top and the other at a high level of the structure's height, particularly if the other outrigger is positioned at ¾ of the structure's height. It is more effective to add double BRB-Os where one is located at the top story rather than between inter-stories. The width-to-depth ratio of the web panel and outrigger width influences the decrease in the VBE's axial forces.