Objectives: Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. Methods: In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. Results: On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. Conclusion: The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. Advances in knowledge: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information. The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.
Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included. All patients had undergone abdominal CT between August 2019 and October 2019. CT-images were reconstructed using the following three methods: filtered back-projection, iterative reconstruction, and PixelShine (DL-software) with both sharp and soft kernels. Stone size, CT attenuation, and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) were evaluated and compared using Bonferroni-corrected Friedman tests. Objective image quality was measured in six regions-of-interest. Stone size ranged between 4.4 × 3.1–4.4 × 3.2 mm (sharp kernel) and 5.1 × 3.8–5.6 × 4.2 mm (soft kernel). Mean attenuation ranged between 704–717 Hounsfield Units (HU) (soft kernel) and 915–1047 HU (sharp kernel). Differences in measured stone sizes were ≤1.3 mm. DL-processed images resulted in significantly higher CNR and SNR values (p < 0.001) by decreasing image noise significantly (p < 0.001). DL-software significantly improved objective image quality while maintaining both correct stone size and CT-attenuation values. Therefore, the clinical impact of stone assessment in denoised image data sets remains unchanged. Through the relevant noise suppression, the software additionally offers the potential to further reduce radiation exposure.