Birte Valentin

Dr. Birte Valentin


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2022 in Abdominal Radiology
Verified
Journal Article
Open access
PDF file
MQM. Quentin
M. Quentin
LSLars Schimmöller
Lars Schimmöller
TUT. Ullrich
T. Ullrich
BVBirte Valentin
Birte Valentin
DDD. Demetrescu
D. Demetrescu
CAC. Arsov
C. Arsov
Purpose: Analysis of patients with pre-operative 3 T multiparametric prostate MRI (mpMRI) to determine reliable MRI-based risk predictors of patients at risk for positive surgical margins (PSM) in robotic assisted radical prostatectomy (RPE). Methods: Consecutive patients with 3 T mpMRI and subsequent RPE from 01/2015 to 12/2018 were retrospectively included. Patients were compared regarding clinical and MRI related parameters such as length of capsular tumor contact (LCC) and distance to the membranous urethra (UD). Results: Forty-nine of 179 patients (27%) had PSM in 70 different localizations, with the majority located at the capsule (57%, 40/70), mostly apical and/or posterior. The second most often PSM occurred at the apical urethra (22%, 15/70). PCA was visible on mpMRI at the localization of PSM in 93% at the capsule and in 80% at the urethra. PSA, PI-RADS classification, extraprostatic extension (EPE), and seminal vesicles infiltration (SVI) on MRI were significantly higher / more frequent in patients with PSM. LCC (AUC 0.710), EPE (AUC 0.693), and UD (1-AUC 0.673) predicted PSM (overall). An UD of ≤ 3.5 mm showed the highest accuracy of 95% (J = 0.946) for PSM at the urethra and a LCC of ≥ 22.5 mm with 77% (J = 0.378) for PSM at the capsule. Conclusion: PSM occurred mostly in the apex and/or posteriorly at the capsule or at the apical urethra. LCC was the best MRI predictor for PSM at the capsule and UD for tumors with PSM at the apical urethra. Using these MRI parameters readers might pre-operatively determine PCA localizations at risk for PSM.

16 January 2021 in Abdominal Radiology
Verified
Journal Article
Open access
PDF file
BVBirte Valentin
Birte Valentin
LSLars Schimmöller
Lars Schimmöller
TUT. Ullrich
T. Ullrich
MKM. Klingebiel
M. Klingebiel
DDD. Demetrescu
D. Demetrescu
CAC. Arsov
C. Arsov
Objectives: The aim of this study was to investigate 3 Tesla multiparametric magnetic resonance imaging (mpMRI)-based predictors for the pretherapeutic T staging of prostate cancer and their accuracy. Methods: Consecutive patients with 3 Tesla mpMRI, positive systematic and MR-targeted biopsy, and subsequent radical prostatectomy (RPE) between 01/2016 and 12/2017 were included. MRI parameters such as measurable extraprostatic extension (EPE) (≥ 3 mm), length of (pseudo)capsular contact (LCC), invasion of neurovascular bundle (NVBI), and/or seminal vesicles lesion contact (SVC) or infiltration (SVI) were assessed and correlated to clinical and histopathological results. Results: 136 men were included. In 76 cases, a pT2 stage was determined, in 29 cases a pT3a, and in 31 a pT3b stage. The positive and negative predictive values (PPV, NPV) for the detection of T3 by measurable EPE on MRI was 98% (CI 0.88–1) and 81% (CI 0.72–0.87). No visible NVBI was found in pT2 patients (NPV 100%; CI 0.95–1). ROC analysis for T3a prediction with LCC (AUC 0.81) showed a sensitivity of 87% and a specificity of 62% at a threshold of 12.5 mm (J = 0.485) and 93% and 58% at 11 mm (Jmax = 0.512). All patients with pT3a had a LCC > 5 mm. In case of pT3b, 29/31 patients showed a SVC (PPV 76%, CI 0.61–0.87; NPV 98%, CI 0.93–0.99), and 23/31 patients showed a SVI (PPV 100%, CI 0.86–1; NPV 93%, CI 0.87–0.96). EPE (p < 0.01), LCC (p = 0.05), and SVC (p = 0.01) were independent predictors of pT3. Conclusions: MRI-measurable EPE, LCC, and SVC were reliable, independent, preoperative predictors for a histopathological T3 stage. A LCC ≥ 11 mm indicated a pT3a stage, whereas a LCC < 5 mm excluded it. On MRI, visible SVI or even SVC of the PCa lesion was reliable preoperative predictors for a pT3b stage.

24 November 2020 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
EBEric Bechler
Eric Bechler
JSJulia Stabinska
Julia Stabinska
TTThomas Andreas Thiel
Thomas Andreas Thiel
JJJonas Jasse
Jonas Jasse
RZRomans Zukovs
Romans Zukovs
ALAlexandra Ljimani
Alexandra Ljimani
Objective: To evaluate the feasibility of in-vivo quantitative susceptibility mapping (QSM) of the human kidney. Methods: An axial single-breath-hold 3D multi-echo sequence (acquisition time 33 s) was completed on a 3 T-MRI-scanner (Magnetom Prisma, Siemens Healthineers, Erlangen, Germany) in 19 healthy volunteers. Graph-cut-based unwrapping combined with the T2*-IDEAL approach was performed to remove the chemical shift of fat and to quantify QSM of the upper abdomen. Mean susceptibility values of the entire, renal cortex and medulla in both kidneys and the liver were determined and compared. Five subjects were measured twice to examine the reproducibility. One patient with severe renal fibrosis was included in the study to evaluate the potential clinical relevance of QSM. Results: QSM was successful in 17 volunteers and the patient with renal fibrosis. Anatomical structures in the abdomen were clearly distinguishable by QSM and the susceptibility values obtained in the liver were comparable to those found in the literature. The results showed a good reproducibility. Besides, the mean renal QSM values obtained in healthy volunteers (0.04 ± 0.07 ppm for the right and − 0.06 ± 0.19 ppm for the left kidney) were substantially higher than that measured in the investigated fibrotic kidney (− 0.43 ± − 0.02 ppm). Conclusion: QSM of the human kidney could be a promising approach for the assessment of information about microscopic renal tissue structure. Therefore, it might further improve functional renal MR imaging.

5 July 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
ASAndrea Steuwe
Andrea Steuwe
BVBirte Valentin
Birte Valentin
OBOliver Thomas Bethge
Oliver Thomas Bethge
ALAlexandra Ljimani
Alexandra Ljimani
GNGünter Niegisch
Günter Niegisch
JAJoel Aissa
Joel Aissa
Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included. All patients had undergone abdominal CT between August 2019 and October 2019. CT-images were reconstructed using the following three methods: filtered back-projection, iterative reconstruction, and PixelShine (DL-software) with both sharp and soft kernels. Stone size, CT attenuation, and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) were evaluated and compared using Bonferroni-corrected Friedman tests. Objective image quality was measured in six regions-of-interest. Stone size ranged between 4.4 × 3.1–4.4 × 3.2 mm (sharp kernel) and 5.1 × 3.8–5.6 × 4.2 mm (soft kernel). Mean attenuation ranged between 704–717 Hounsfield Units (HU) (soft kernel) and 915–1047 HU (sharp kernel). Differences in measured stone sizes were ≤1.3 mm. DL-processed images resulted in significantly higher CNR and SNR values (p < 0.001) by decreasing image noise significantly (p < 0.001). DL-software significantly improved objective image quality while maintaining both correct stone size and CT-attenuation values. Therefore, the clinical impact of stone assessment in denoised image data sets remains unchanged. Through the relevant noise suppression, the software additionally offers the potential to further reduce radiation exposure.

22 March 2024 in European Journal of Radiology
Verified
Journal Article
Open access
MQM. Quentin
M. Quentin
MBMatthias Boschheidgen
Matthias Boschheidgen
JRJ.P. Radtke
J.P. Radtke
FSF. Spohn
F. Spohn
TUTim Ullrich
Tim Ullrich
LSLars Schimmöller
Lars Schimmöller
Purpose: Patients with suspicion of clinically significant prostate cancer (csPC) on multiparametric prostate MRI (mpMRI) but negative or inconclusive MRI/US fusion-guided biopsy (FB) can be challenging in clinical practice. To assess the utility of MRI in -bore biopsy (IB) in patients with discordant imaging and histopathological findings after FB. Methods: Consecutive patients with Prostate Imaging Reporting and Data System (PI-RADS) category 4 or 5 on mpMRI at 3T after FB without histologically confirmed csPC who underwent IB between 01/2014 and 05/2022, were retrospectively included. The primary objective was to assess the detection rate of csPC. Secondary objectives were to analyze clinical parameters, MRI parameters, and lesion localization. Results: In the final cohort of 51 patients, the IB resulted in an overall detection rate of 71% for PC and 47% for csPC. Furthermore, in 55% of cases with initial low-grade PC, the Gleason score was upgraded after IB. CsPC was often detected apical and/or anterior. The detection rate for PC was 58% in PI-RADS category 4 and 94% in PIRADS category 5 (csPC 39% and 61%, respectively). Patients with csPC had statistically significant smaller prostate volumes, a higher PI-RADS category, a higher prostate-specific antigen density (PSAD), and were older. Conclusions: For a relevant proportion of patients with PI-RADS category 4 or 5 and negative or inconclusive findings on previous FB, but with persistent suspicion of csPC, a subsequent IB verified the presence of csPC. Therefore, IB can be a backup in cases of uncertainty.

1 February 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
BVBirte Valentin
Birte Valentin
CAC. Arsov
C. Arsov
TUT. Ullrich
T. Ullrich
DDD. Demetrescu
D. Demetrescu
JMJanna Morawitz
Janna Morawitz
LSLars Schimmöller
Lars Schimmöller