Marco Alexander Wiesmueller

Dr. Marco Alexander Wiesmueller

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MWMarco Alexander Wiesmueller
Marco Alexander Wiesmueller
WWWolfgang Wuest
Wolfgang Wuest
RHRafael Heiss
Rafael Heiss
CTChristoph Treutlein
Christoph Treutlein
MUMichael Uder
Michael Uder
MMMatthias Stefan May
Matthias Stefan May
Interpretation of T2 values remains difficult due to limited comparability across hardware and software systems and the lack of validated measurement recommendations for the number and orientation of mandatory slices. Our aims were to provide a standardized comparison of intra- and inter-individual T2 values in the short and long axes and to investigate inter-scanner reproducibility. Ninety cardiovascular magnetic resonance (CMR) studies in 30 healthy subjects were performed with three identical 1.5 T CMR scanners (same hardware and software) using a balanced steady-state free precession (bSSFP) gradient echo sequence in three short axis (SAx) and three long axis (LAx) views. A commercially available T2 mapping software package of the latest generation with automatic in-line motion correction was used for acquisition. Regions of interest were manually drawn in each of the 16 myocardial segments according to the American Heart Association (AHA) model in three SAx and three LAx acquisitions. Analysis of inter-scanner, inter-segmental, intra-segmental, inter-regional and inter-level differences was performed. Inter-scanner reproducibility was high and the mean myocardial T2 value for all evaluated segments was 45.7 ± 3.4 ms. Significant inter-segmental variations of mean T2 values were found. Mean intra-segmental T2 values were comparable between LAx and SAx acquisitions in 72%. Significantly higher T2 values were found in apical segments and a significant disparity among different regions was found for SAx and LAx orientations. Standardized cardiac T2 mapping is highly reproducible on identical CMR systems. T2 values vary significantly between single heart segments, regions, levels, and axes in young, healthy subjects.

1 March 2024 in Investigative Radiology
Verified
Journal Article
Open access
MKMarkus Kopp
Markus Kopp
MWMarco Alexander Wiesmueller
Marco Alexander Wiesmueller
Mayte BuchbenderMayte Buchbender
Mayte Buchbender
MKMarco Kesting
Marco Kesting
ANArmin M. Nagel
Armin M. Nagel
RHRafael Heiss
Rafael Heiss
Objectives: Temporomandibular disorders (TMDs) are common and may cause persistent functional limitations and pain. Magnetic resonance imaging (MRI) at 1.5 and 3 T is commonly applied for the evaluation of the temporomandibular joint (TMJ). No evidence is available regarding the feasibility of modern low-field MRI for the assessment of TMDs. The objective of this prospective study was to evaluate the image quality (IQ) of 0.55 T MRI in direct comparison with 1.5 T MRI. Materials and Methods: Seventeen patients (34 TMJs) with suspected intraarticular TMDs were enrolled, and both 0.55 and 1.5 T MRI were performed on the same day. Two senior readers independently evaluated the IQ focusing on the conspicuity of disc morphology (DM), disc position (DP), and osseous joint morphology (OJM) for each joint. We analyzed the IQ and degree of artifacts using a 4-point Likert scale (LS) at both field strengths. A fully sufficient IQ was defined as an LS score of ≥3. Nonparametric Wilcoxon test for related samples was used for statistical comparison. Results: The median IQ for the DM and OJM at 0.55 T was inferior to that at 1.5 T (DM: 3 [interquartile range {IQR}, 3–4] vs 4 [IQR, 4–4]; OJM: 3 [IQR, 3–4] vs 4 [IQR 4–4]; each P < 0.001). For DP, the IQ was comparable (4 [IQR 3–4] vs 4 [IQR 4–4]; P > 0.05). A sufficient diagnostic IQ was maintained for the DM, DP, and OJM in 92% of the cases at 0.55 T and 100% at 1.5 T. Minor image artifacts (LS score of ≥3) were more prevalent at 0.55 T (29%) than at 1.5 T (12%). Conclusions: Magnetic resonance imaging of the TMJ at 0.55 T yields a lower IQ than does MRI at 1.5 T but maintains sufficient diagnostic confidence in the majority of patients. Further improvements are needed for reliable clinical application.

31 August 2021 in Investigative Radiology
Verified
Journal Article
Open access
Matthias MayMatthias May
Matthias May
RHRafael Heiss
Rafael Heiss
JKJulia Koehnen
Julia Koehnen
MWMatthias Wetzl
Matthias Wetzl
MWMarco Alexander Wiesmueller
Marco Alexander Wiesmueller
MKMarkus Kopp
Markus Kopp
Objectives: The purpose of this study was to evaluate the minimum diagnostic radiation dose level for the detection of high-resolution (HR) lung structures, pulmonary nodules (PNs), and infectious diseases (IDs). Materials and Methods: A preclinical chest computed tomography (CT) trial was performed with a human cadaver without known lung disease with incremental radiation dose using tin filter-based spectral shaping protocols. A subset of protocols for full diagnostic evaluation of HR, PN, and ID structures was translated to clinical routine. Also, a minimum diagnostic radiation dose protocol was defined (MIN). These protocols were prospectively applied over 5 months in the clinical routine under consideration of the individual clinical indication. We compared radiation dose parameters, objective and subjective image quality (IQ). Results: The HR protocol was performed in 38 patients (43%), PN in 21 patients (24%), ID in 20 patients (23%), and MIN in 9 patients (10%). Radiation dose differed significantly among HR, PN, and ID (5.4, 1.2, and 0.6 mGy, respectively; P < 0.001). Differences between ID and MIN (0.2 mGy) were not significant (P = 0.262). Dose-normalized contrast-to-noise ratio was comparable among all groups (P = 0.087). Overall IQ was perfect for the HR protocol (median, 5.0) and decreased for PN (4.5), ID-CT (4.3), and MIN-CT (2.5). The delineation of disease-specific findings was high in all dedicated protocols (HR, 5.0; PN, 5.0; ID, 4.5). The MIN protocol had borderline IQ for PN and ID lesions but was insufficient for HR structures. The dose reductions were 78% (PN), 89% (ID), and 97% (MIN) compared with the HR protocols. Conclusions: Personalized chest CT tailored to the clinical indications leads to substantial dose reduction without reducing interpretability. More than 50% of patients can benefit from such individual adaptation in a clinical routine setting. Personalized radiation dose adjustments with validated diagnostic IQ are especially preferable for evaluating ID and PN lesions.

29 April 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
MWMarco Alexander Wiesmueller
Marco Alexander Wiesmueller
WWW. Wuest
W. Wuest
Matthias MayMatthias May
Matthias May
Stephan EllmannStephan Ellmann
Stephan Ellmann
RHRafael Heiss
Rafael Heiss
FLFrederik Bernd Laun
Frederik Bernd Laun
BACKGROUND AND PURPOSE: The high diagnostic value of DWI for cholesteatoma diagnostics is undisputed. This study compares the diagnostic value of readout-segmented echo-planar DWI and single-shot TSE DWI for cholesteatoma diagnostics. MATERIALS AND METHODS: Thirty patients with newly suspected cholesteatoma were examined with a dedicated protocol, including readout-segmented echo-planar DWI and single-shot TSE DWI at 1.5T. Acquisition parameters of both diffusion-weighted sequences were as follows: b=1000 s/mm,2 axial and coronal section orientations, and section thickness of 3 mm. Image quality was evaluated by 2 readers on a 5-point Likert scale with respect to lesion conspicuity, the presence of susceptibility artifacts mimicking cholesteatomas, and overall subjective image quality. Sensitivity and specificity were calculated using histology results as the gold standard. RESULTS: Twenty-five cases of histologically confirmed cholesteatomas were included in the study group. Lesion conspicuity was higher and fewer artifacts were found when using TSE DWI (both P < .001). The overall subjective image quality, however, was better with readout-segmented DWI. For TSE DWI, the sensitivity for readers 1 and 2 was 92% (95% CI, 74%–99%) and 88% (95% CI, 69%–97%), respectively, while the specificity for both readers was 80% (95% CI, 28%–99%). For readout-segmented DWI, the sensitivity for readers 1 and 2 was 76% (95% CI, 55%–91%) and 68% (95% CI, 46%–85%), while the specificity for both readers was 60% (95% CI, 15%–95%). CONCLUSIONS: The use of TSE DWI is advisable for cholesteatoma diagnostics and preferable over readout-segmented DWI.

20 April 2022 in European Radiology
Verified
Journal Article
Open access
PDF file
ABAndreas Bedernik
Andreas Bedernik
WWWolfgang Wuest
Wolfgang Wuest
MMMatthias Stefan May
Matthias Stefan May
RHRafael Heiss
Rafael Heiss
MUMichael Uder
Michael Uder
MWMarco Alexander Wiesmueller
Marco Alexander Wiesmueller
Objectives: The aim of this study was to compare the quality of images obtained using single-energy computed tomography (SECT) performed with automated tube voltage adaptation (TVA) with dual-energy CT (DECT) weighted average images. Methods: Eighty patients were prospectively randomized to undergo either SECT with TVA (n = 40, ref. mAs 200) or radiation dose–matched DECT (n = 40, 80/Sn150 kV, ref. mAs tube A 91/tube B 61) on a dual-source CT scanner. Objective image quality was evaluated as dose-normalized contrast-to-noise ratio (CNRD) for the jugular veins relative to fatty tissue and muscle tissue and for muscle tissue relative to fatty issue. For subjective image quality, reproduction of anatomical structures, image artifacts, image noise, spatial resolution, and overall diagnostic acceptability were evaluated at sixteen anatomical substructures using Likert-type scales. Results: Effective radiation dose (ED) was comparable between SECT and DECT study groups (2.9 ± 0.6 mSv/3.1 ± 0.7 mSv, p = 0.5). All examinations were rated as excellent or good for clinical diagnosis. Compared to the CNRD in the SECT group, the CNRD in the DECT group was significantly higher for the jugular veins relative to fatty tissue (7.51/6.08, p < 0.001) and for muscle tissue relative to fatty tissue (4.18/2.90, p < 0.001). The CNRD for the jugular veins relative to muscle tissue (3.33/3.18, p = 0.51) was comparable between groups. Image artifacts were less pronounced and overall diagnostic acceptability was higher in the DECT group (all p = 0.01). Conclusions: DECT weighted average images deliver higher objective and subjective image quality than SECT performed with TVA in head and neck imaging. Key Points: • Weighted average images derived from dual-energy CT deliver higher objective and subjective image quality than single-energy CT using automated tube voltage adaptation in head and neck imaging. • If available, dual-energy CT acquisition may be preferred over automated low tube voltage adopted single-energy CT for both malignant and non-malignant conditions.

1 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
THTobias Hepp
Tobias Hepp
WWWolfgang Wuest
Wolfgang Wuest
RHRafael Heiss
Rafael Heiss
Matthias MayMatthias May
Matthias May
MKMarkus Kopp
Markus Kopp
MWMarco Alexander Wiesmueller
Marco Alexander Wiesmueller
The aim of this study was to assess the diagnostic value of ADC distribution curves for differentiation between benign and malignant parotid gland tumors and to compare with mean ADC values. 73 patients with parotid gland tumors underwent head-and-neck MRI on a 1.5 Tesla scanner prior to surgery and histograms of ADC values were extracted. Histopathological results served as a reference standard for further analysis. ADC histograms were evaluated by comparing their similarity to a reference distribution using Chi2-test-statistics. The assumed reference distribution for benign and malignant parotid gland lesions was calculated after pooling the entire ADC data. In addition, mean ADC values were determined. For both methods, we calculated and compared the sensitivity and specificity between benign and malignant parotid gland tumors and three subgroups (pleomorphic adenoma, Warthin tumor, and malignant lesions), respectively. Moreover, we performed cross-validation (CV) techniques to estimate the predictive performance between ADC distributions and mean values. Histopathological results revealed 30 pleomorphic adenomas, 22 Warthin tumors, and 21 malignant tumors. ADC histogram distribution yielded a better specificity for detection of benign parotid gland lesions (ADChistogram: 75.0% vs. ADCmean: 71.2%), but mean ADC values provided a higher sensitivity (ADCmean: 71.4% vs. ADChistogram: 61.9%). The discrepancies are most pronounced in the differentiation between malignant and Warthin tumors (sensitivity ADCmean: 76.2% vs. ADChistogram: 61.9%; specificity ADChistogram: 81.8% vs. ADCmean: 68.2%). Using CV techniques, ADC distribution revealed consistently better accuracy to differentiate benign from malignant lesions (“leave-one-out CV” accuracy ADChistogram: 71.2% vs. ADCmean: 67.1%). ADC histogram analysis using full distribution curves is a promising new approach for differentiation between primary benign and malignant parotid gland tumors, especially with respect to the advantage in predictive performance based on CV techniques.