High penetration of wind power with conventional grid following controls for inverter-based wind turbine generators (WTGs) weakens the power grid, challenging the power system stability. Grid-forming (GFM) controls are emerging technologies that can address such stability issues. Numerous methodologies of GFM inverters have been developed in the literature; however, their applications for WTGs have not been thoroughly explored. As WTGs need to incorporate multiple control functions to operate reliably in different operational regions, the GFM control should be appropriately developed for the WTGs. This paper presents a review of GFM controls for WTGs, which covers the latest developments in GFM controls and includes multi-loop and single-loop GFM, virtual synchronous machine-based GFM, and virtual inertia control-based GFM. A comparison study for these GFM-based WTGs regarding normal and abnormal operating conditions together with black-start capability is then performed. The control parameters of these GFM types are properly designed and optimized to enable a fair comparison. In addition, the challenges of applying these GFM controls to wind turbines are discussed, which include the impact of DC-link voltage control strategy and the current saturation algorithm on the GFM control performance, black-start capability, and autonomous operation capability. Finally, recommendations and future developments of GFM-based wind turbines to increase the power system reliability are presented.
This paper presents the operation modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is discussed. The case studies and real-time simulation results are provided using Typhoon HIL to back the theoretical investigation.
Reducing the fuel consumption within a power network is crucial to enhance the overall system efficiency and minimize operating costs. Fuel consumption minimization can be achieved through different optimization techniques where the output power of the generators is regulated based on their individual efficiency characteristics. Existing studies primarily focus either on maximizing the efficiency function or minimizing the operating cost function of the generators to minimize fuel consumption. However, for practical implementation, it becomes imperative to incorporate a function within the optimization framework to represent the fuel consumption rate directly. This study introduces a novel approach by formulating a minimization problem with a sum-of-ratios objective function representing the fuel consumption rate. However, optimization problems with sum-of-ratios objective functions or constraints are extremely challenging to solve because of their strong nonlinearity. To efficiently solve the formulated problem, a fractional programming (FP) approach is adopted in this study. This reformulation technique significantly reduces the solution time of the optimization problem and provides a better solution than nonlinear programming (NLP). In addition, the reformulated problem can also be applied to large-scale systems where the NLP fails to converge. The proposed methodology of this study is tested on the notional MVAC ship system, modified IEEE 30-bus and IEEE 118-bus systems. The results demonstrate that the model successfully minimizes fuel consumption by effectively scheduling the generator and ESS dispatch.
This paper presents an original energy management methodology to enhance the resilience of ship power systems. The integration of various energy storage systems (ESS), including battery energy storage systems (BESS) and super-capacitor energy storage systems (SCESS), in modern ship power systems poses challenges in designing an efficient energy management system (EMS). The EMS proposed in this paper aims to achieve multiple objectives. The primary objective is to minimize shed loads, while the secondary objective is to effectively manage different types of ESS. Considering the diverse ramp-rate characteristics of generators, SCESS, and BESS, the proposed EMS exploits these differences to determine an optimal long-term schedule for minimizing shed loads. Furthermore, the proposed EMS balances the state-of-charge (SoC) of ESS and prioritizes the SCESS's SoC levels to ensure the efficient operation of BESS and SCESS. For better computational efficiency, we introduce the receding horizon optimization method, enabling real-time EMS implementation. A comparison with the fixed horizon optimization (FHO) validates its effectiveness. Simulation studies and results demonstrate that the proposed EMS efficiently manages generators, BESS, and SCESS, ensuring system resilience under generation shortages. Additionally, the proposed methodology significantly reduces the computational burden compared to the FHO technique while maintaining acceptable resilience performance.
This paper presents developed real-time simulation models for offshore wind turbine generators in compliance with industry standards. The critical control functions such as negative sequence injection, sequence current limit, voltage ride through, and power curtailments are designed to meet the industry requirements for future electromagnetic transient (EMT) testing and controls of offshore wind farms. Average-value and switching detailed models are developed in the Opal-RT real-time simulator. Real-time capabilities of these models are compared to show the effectiveness of the average-value model in terms of accuracy and computation efficiency. Studies of balanced and unbalanced faults illustrate the ability of the proposed turbine models to inject active and reactive currents during fault events. The models are validated against the second-generation generic wind turbine model proposed by Western Electricity Coordinating Council (WECC). Validation results reveal that the proposed models are aligned with the WECC generic model. In addition, the models provide an extended capability in mitigating the active power oscillation during unbalanced fault conditions.
This paper presents a 1-D convolutional graph neural network for fault detection in microgrids. The combination of 1-D convolutional neural networks (1D-CNN) and graph convolutional networks (GCN) helps extract both spatial-temporal correlations from the voltage measurements in microgrids. The fault detection scheme includes fault event detection, fault type and phase classification, and fault location. There are five neural network model training to handle these tasks. Transfer learning and fine-tuning are applied to reduce training efforts. The combined recurrent graph convolutional neural networks (1D-CGCN) is compared with the traditional ANN structure on the Potsdam 13-bus microgrid dataset. The achievable accuracy of 99.27%, 98.1%, 98.75%, and 95.6% for fault detection, fault type classification, fault phase identification, and fault location respectively.