Emma Harris

Dr. Emma Harris

The Institute of Cancer Research and Royal Marsden Hospital NHS Foundation Trust, Radiotherapy and Imaging, London SM2 5PT, UK

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JBJenny Bertholet
Jenny Bertholet
AKAntje-Christin Knopf
Antje-Christin Knopf
BEBjörn Eiben
Björn Eiben
JMJamie R McClelland
Jamie R McClelland
AGAlexander Grimwood
Alexander Grimwood
UOUwe Oelfke
Uwe Oelfke
Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is constantly moving due to respiratory, cardiac, gastrointestinal and urinary activity. The long term goal of the RT community to ‘see what we treat, as we treat’ and to act on this information instantaneously has resulted in rapid technological innovation. Specialized treatment machines, such as robotic or gimbal-steered linear accelerators (linac) with in-room imaging suites, have been developed specifically for real-time treatment adaptation. Additional equipment, such as stereoscopic kilovoltage (kV) imaging, ultrasound transducers and electromagnetic transponders, has been developed for intrafraction motion monitoring on conventional linacs. Magnetic resonance imaging (MRI) has been integrated with cobalt treatment units and more recently with linacs. In addition to hardware innovation, software development has played a substantial role in the development of motion monitoring methods based on respiratory motion surrogates and planar kV or Megavoltage (MV) imaging that is available on standard equipped linacs. In this paper, we review and compare the different intrafraction motion monitoring methods proposed in the literature and demonstrated in real-time on clinical data as well as their possible future developments. We then discuss general considerations on validation and quality assurance for clinical implementation. Besides photon RT, particle therapy is increasingly used to treat moving targets. However, transferring motion monitoring technologies from linacs to particle beam lines presents substantial challenges. Lessons learned from the implementation of real-time intrafraction monitoring for photon RT will be used as a basis to discuss the implementation of these methods for particle RT.

22 March 2016 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
TOTuathan O’shea
Tuathan O’shea
Jeffrey BamberJeffrey Bamber
Jeffrey Bamber
Davide FontanarosaDavide Fontanarosa
Davide Fontanarosa
SMSkadi van der Meer
Skadi van der Meer
FVFrank Verhaegen
Frank Verhaegen
EHEmma Harris
Emma Harris
Imaging has become an essential tool in modern radiotherapy (RT), being used to plan dose delivery prior to treatment and verify target position before and during treatment. Ultrasound (US) imaging is cost-effective in providing excellent contrast at high resolution for depicting soft tissue targets apart from those shielded by the lungs or cranium. As a result, it is increasingly used in RT setup verification for the measurement of inter-fraction motion, the subject of Part I of this review (Fontanarosa et al 2015 Phys. Med. Biol. 60 R77-114). The combination of rapid imaging and zero ionising radiation dose makes US highly suitable for estimating intra-fraction motion. The current paper (Part II of the review) covers this topic. The basic technology for US motion estimation, and its current clinical application to the prostate, is described here, along with recent developments in robust motion-estimation algorithms, and three dimensional (3D) imaging. Together, these are likely to drive an increase in the number of future clinical studies and the range of cancer sites in which US motion management is applied. Also reviewed are selections of existing and proposed novel applications of US imaging to RT. These are driven by exciting developments in structural, functional and molecular US imaging and analytical techniques such as backscatter tissue analysis, elastography, photoacoustography, contrast-specific imaging, dynamic contrast analysis, microvascular and super-resolution imaging, and targeted microbubbles. Such techniques show promise for predicting and measuring the outcome of RT, quantifying normal tissue toxicity, improving tumour definition and defining a biological target volume that describes radiation sensitive regions of the tumour. US offers easy, low cost and efficient integration of these techniques into the RT workflow. US contrast technology also has potential to be used actively to assist RT by manipulating the tumour cell environment and by improving the delivery of radiosensitising agents. Finally, US imaging offers various ways to measure dose in 3D. If technical problems can be overcome, these hold potential for wide-dissemination of cost-effective pre-treatment dose verification and in vivo dose monitoring methods. It is concluded that US imaging could eventually contribute to all aspects of the RT workflow.

1 May 2012 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
EHEmma Harris
Emma Harris
EDEllen M. Donovan
Ellen M. Donovan
CCCharlotte E. Coles
Charlotte E. Coles
HBHans C.J. de Boer
Hans C.J. de Boer
APAndrew Poynter
Andrew Poynter
PEPhilip M evans
Philip M evans

1 July 2019 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Open access
SMSarah A. Mason
Sarah A. Mason
IWIngrid M. White
Ingrid M. White
TOTuathan O'SHea
Tuathan O'SHea
HMHelen A. McNair
Helen A. McNair
SASophie Alexander
Sophie Alexander
SLSusan Lalondrelle
Susan Lalondrelle
Adaptive radiation therapy strategies could account for interfractional uterine motion observed in patients with cervix cancer, but the current cone beam computed tomography (CBCT)-based treatment workflow is limited by poor soft-tissue contrast. The goal of the present study was to determine if ultrasound (US) could be used to improve visualization of the uterus, either as a single modality or in combination with CBCT. Interobserver uterine contour agreement and confidence were compared on 40 corresponding CBCT, US, and CBCT-US-fused images from 11 patients with cervix cancer. Contour agreement was measured using the Dice similarity coefficient (DSC) and mean contour-to-contour distance (MCCD). Observers rated their contour confidence on a scale from 1 to 10. Pairwise Wilcoxon signed-rank tests were used to measure differences in contour agreement and confidence. CBCT-US fused images had significantly better contour agreement and confidence than either individual modality (P < .05), with median (interquartile range [IQR]) values of 0.84 (0.11), 1.26 (0.23) mm, and 7 (2) for the DSC, MCCD, and observer confidence ratings, respectively. Contour agreement was similar between US and CBCT, with median (IQR) DSCs of 0.81 (0.17) and 0.82 (0.14) and MCCDs of 1.75 (1.15) mm and 1.62 (0.74) mm. Observers were significantly more confident in their US-based contours than in their CBCT-based contours (P < .05), with median (IQR) confidence ratings of 7 (2.75) versus 5 (4). CBCT and US are complementary and improve uterine segmentation precision when combined. Observers could localize the uterus with a similar precision on independent US and CBCT images.

12 April 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
PJPrabhjot Juneja
Prabhjot Juneja
PEPhilip M evans
Philip M evans
EHEmma Harris
Emma Harris
Validation is required to ensure automated segmentation algorithms are suitable for radiotherapy target definition. In the absence of true segmentation, algorithmic segmentation is validated against expert outlining of the region of interest. Multiple experts are used to overcome inter-expert variability. Several approaches have been studied in the literature, but the most appropriate approach to combine the information from multiple expert outlines, to give a single metric for validation, is unclear. None consider a metric that can be tailored to case-specific requirements in radiotherapy planning. Validation index (VI), a new validation metric which uses experts' level of agreement was developed. A control parameter was introduced for the validation of segmentations required for different radiotherapy scenarios: for targets close to organs-at-risk and for difficult to discern targets, where large variation between experts is expected. VI was evaluated using two simulated idealized cases and data from two clinical studies. VI was compared with the commonly used Dice similarity coefficient (DSCpair-wise) and found to be more sensitive than the to the changes in agreement between experts. VI was shown to be adaptable to specific radiotherapy planning scenarios.

1 July 2019 in Radiotherapy and Oncology
Verified
Journal Article
Open access
IBIndrani S. Bhattacharya
Indrani S. Bhattacharya
JHJoanne S. Haviland
Joanne S. Haviland
CPCarola Perotti
Carola Perotti
DEDavid Eaton
David Eaton
SGSarah Gulliford
Sarah Gulliford
AKAnna M. Kirby
Anna M. Kirby
Background: Seroma describes a collection of serous fluid within a cavity, occurring following surgery. Seroma is associated with normal tissue effects (NTE) following breast radiotherapy, as reported by clinicians and on photographs. This study investigates the association between seroma and the NTE breast appearance change collected using patient-reported outcome measures (PROMs) in IMPORT HIGH, as well as investigating the association between breast appearance change and patient/tumour/treatment factors. Methods: Case-control methodology was used for seroma analysis within IMPORT HIGH. Cases were patients reporting moderate/marked breast appearance change and controls reported none/mild changes at year-3. One control was selected at random for each case. Seromas were graded as not visible/subtle or visible/highly visible on CT radiotherapy planning scans. Logistic regression tested associations, adjusting for patient/tumour/treatment factors. Results: 1078/1149 patients consented to PROMs, of whom 836 (78%) reported whether they had 3-year breast appearance change; 231 cases and 231 controls were identified. 304/462 (66%) patients received chemotherapy. Seroma prevalence was 20% (41/202) in cases and 16% (32/205) in controls, and less frequent in patients receiving adjuvant chemotherapy [10% (24/246) compared with 29% (40/138) without]. Visible seroma was not significantly associated with breast appearance change [OR 1.38 (95% CI 0.832.29), p = 0.219]. Larger tumour size, haematoma, current smoking and body image concerns at baseline were independent risk factors. Conclusions: Seroma was not associated with patient-reported breast appearance change, but haematoma and smoking were significant risk factors. Lack of association may be related to lower prevalence of seroma compared with previous reports, perhaps reflecting patients receiving adjuvant chemotherapy in whom seroma resolves prior to radiotherapy. (C) 2019 The Authors. Published by Elsevier B. V. Radiotherapy and Oncology 136 (2019) 190-196 This is an open access article under the CC BY license (http://creativecommons. org/licenses/by/4.0/).