Rossana Scarpone

Dr. Rossana Scarpone

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2004 in Journal of Chromatography A
Verified
Journal Article
Closed access
GDGianfranco Diletti
Gianfranco Diletti
GSGiampiero Scortichini
Giampiero Scortichini
RSRossana Scarpone
Rossana Scarpone
GGGiuseppe Gatti
Giuseppe Gatti
LTLuigi Torreti
Luigi Torreti
GMGiacomo Migliorati
Giacomo Migliorati

1 March 2018 in Food Control
Verified
Journal Article
Closed access
GSGino Angelo Santarelli
Gino Angelo Santarelli
GMGiacomo Migliorati
Giacomo Migliorati
FPFrancesco Pomilio
Francesco Pomilio
CMCristina Marfoglia
Cristina Marfoglia
PCPatrizia Centorame
Patrizia Centorame
LILuigi Iannetti
Luigi Iannetti

25 November 2016 in Food Analytical Methods
Verified
Journal Article
Closed access
PDF file
FOFrancesca Di Ottavio
Francesca Di Ottavio
FPFlavio Della Pelle
Flavio Della Pelle
Camilla MontesanoCamilla Montesano
Camilla Montesano
RSRossana Scarpone
Rossana Scarpone
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Manuel SergiManuel Sergi
Manuel Sergi

22 December 2015 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
FPFlavio Della Pelle
Flavio Della Pelle
MCMaria Chiara Di Crescenzo
Maria Chiara Di Crescenzo
Manuel SergiManuel Sergi
Manuel Sergi
Camilla MontesanoCamilla Montesano
Camilla Montesano
FOFrancesca Di Ottavio
Francesca Di Ottavio
Dario CompagnoneDario Compagnone
Dario Compagnone
A rapid, selective and effective method of extraction, clean-up and concentration of organophosphorous pesticides from wheat followed by electrospray (ESI) LC-MS/MS analysis was developed. The μ-SPE (micro-solid-phase extraction) procedure resulted in good analytical performance and reduced at the same time matrix effects, analysis time and solvent consumption. Limits of detection (LODs) and quantification (LOQs) were in the range of 0.3–10 and 1–30 μg kg−1, respectively, with good reproducibility (RSD ≤ 13.8) and recoveries between 75% and 109%. Coefficients of determination (r2) were greater than 0.996 for the studied pesticides. Despite the reduced sorbent bed mass of μ-SPE tips (4.2 mg), the analytical data showed that no saturation phenomena occurs in the tested range of concentration both for single compounds and mixtures. Several real samples were analysed and the concentrations of the selected pesticides were found to be below the respective maximum residue limit (MRLs).

19 February 2020 in Food Analytical Methods
Verified
Journal Article
Open access
PDF file
RSRossana Scarpone
Rossana Scarpone
RRRoberta Rosato
Roberta Rosato
FCFrancesco Chiumiento
Francesco Chiumiento
CCChiara Cipolletti
Chiara Cipolletti
MSManuel Sergi
Manuel Sergi
DCDario Compagnone
Dario Compagnone
This preliminary study describes the use of high resolution and accuracy mass spectrometry techniques combined with new generation chemical software products for detecting and identifying contaminants in food commodities. As a first step, the extracts of routine target analysis samples (obtained in our official laboratory responsible for food residues control) were acquired and processed with this method in order to search unknown and non-targeted contaminants in food. In order to verify the feasibility of the presented method, the research has been firstly addressed to untargeted pesticides and their metabolites in stone fruits commodities and tomatoes. The differential analysis carried with Compound Discoverer 2.0 between the investigated unknown sample and the blank matrix sample allowed to remove all the matrix molecular components; Aggregated Computational Toxicology Resource (ACToR) helped to understand and predict chemical interpretation of substances. The acquisition in FullScan-AIF and FullScan-ddMS2 allowed the clear detection and identification of isobaric compounds such as quinalphos and phoxim. In order to verify that the proposed method is suitable to the scope of application, the main points of SANTE/11813/2017 Document have been followed. The results demonstrate that no false positives and no false negatives have been detected from the analysis of samples spiked with 55 pesticides at 0.010 and 0.10 mg kg−1. This preliminary study has been also tested with a Proficiency Test (EUPT-FV-SM08) and, according to EUPT-FV-SM08 Final Report, our laboratory has been included in the 67% (56) that clearly detected over 70% pesticides. Finally, this method has been extended to other matrices and contaminants.

9 August 2022 in Foods
Verified
Journal Article
Open access
PDF file
RRRachele Rocchi
Rachele Rocchi
RRRoberta Rosato
Roberta Rosato
MBmirella bellocci
mirella bellocci
GMGiacomo Migliorati
Giacomo Migliorati
RSRossana Scarpone
Rossana Scarpone
The new scenario for global food production and supply is decidedly complex given the current forecast of an increase in food fragility due to international tensions. In this period, exports from other parts of the world require different routes and treatments to preserve the food quality and integrity. Fumigation is a procedure used for the killing, removal, or rendering infertile of pests, with serious dangers to human health. The most-used fumigants are methyl bromide and ethylene dibromide. It is important to bear in mind that the soil may contain bromide ions naturally or from anthropogenic source (fertilizers and pesticides that contain bromide or previous fumigations). Different methods (titrimetric, spectrophotometric, and fluorometric approaches) are available to rapidly determine the amount of bromide ion on site in the containers, but these are non-specific and with high limits of quantification. The increasing interest in healthy food, without xenobiotic residues, requires the use of more sensitive, specific, and accurate analytical methods. In order to help give an overview of the bromide ion scenario, a new, fast method was developed and validated according to SANTE 11312/2021. It involves the determination of bromide ion in cereals and legumes through ion chromatography–Q-Orbitrap. The extraction was performed by the QuPPe method, but some modifications were applied based on the matrix. The method described here was validated at four different levels. Recoveries were satisfactory and the mean values ranged between 99 and 106%, with a relative standard deviation lower than 3%. The linearity in the matrix was evaluated to be between 0.010 and 2.5 mg kg−1, with a coefficient of determination (R2) of 0.9962. Finally, the proposed method was applied to different cereals and legumes (rice, wheat, beans, lentils pearled barley, and spelt) and tested with satisfactory results in EUPT-SMR16 organized by EURL.