Jiyo Srinivasan Athertya

Dr. Jiyo Srinivasan Athertya

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JAJiyo Srinivasan Athertya
Jiyo Srinivasan Athertya
YMYajun Ma
Yajun Ma
AAAmir Masoud Afsahi
Amir Masoud Afsahi
ALAlecio Lombardi
Alecio Lombardi
DMDina Moazamian
Dina Moazamian
HJHyungseok Jang
Hyungseok Jang
In this study, the feasibility of accelerated quantitative Ultrashort Echo Time Cones (qUTE-Cones) imaging with compressed sensing (CS) reconstruction is investigated. qUTE-Cones sequences for variable flip angle-based UTE T1 mapping, UTE adiabatic T1ρ mapping, and UTE quantitative magnetization transfer modeling of macromolecular fraction (MMF) were implemented on a clinical 3T MR system. Twenty healthy volunteers were recruited and underwent whole-knee MRI using qUTE-Cones sequences. The k-space data were retrospectively undersampled with different undersampling rates. The undersampled qUTE-Cones data were reconstructed using both zero-filling and CS reconstruction. Using CS-reconstructed UTE images, various parameters were estimated in 10 different regions of interests (ROIs) in tendons, ligaments, menisci, and cartilage. Structural similarity, percentage error, and Pearson’s correlation were calculated to assess the performance. Dramatically reduced streaking artifacts and improved SSIM were observed in UTE images from CS reconstruction. A mean SSIM of ~0.90 was achieved for all CS-reconstructed images. Percentage errors between fully sampled and undersampled CS-reconstructed images were below 5% for up to 50% undersampling (i.e., 2× acceleration). High linear correlation was observed (>0.95) for all qUTE parameters estimated in all subjects. CS-based reconstruction combined with efficient Cones trajectory is expected to achieve a clinically feasible scan time for qUTE imaging.

23 September 2023 in NMR in Biomedicine
Verified
Journal Article
Closed access
DMDina Moazamian
Dina Moazamian
JAJiyo Srinivasan Athertya
Jiyo Srinivasan Athertya
SDSophia Dwek
Sophia Dwek
ALAlecio Lombardi
Alecio Lombardi
HMHamidreza Shaterian Mohammadi
Hamidreza Shaterian Mohammadi
ECEric Y. Chang
Eric Y. Chang

28 August 2024 in NMR in Biomedicine
Verified
Journal Article
Closed access
JAJiyo Srinivasan Athertya
Jiyo Srinivasan Athertya
ASArya Suprana
Arya Suprana
JLJames Lo
James Lo
ALAlecio Lombardi
Alecio Lombardi
DMDina Moazamian
Dina Moazamian
YMYajun Ma
Yajun Ma

28 May 2021 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
JAJiyo Srinivasan Athertya
Jiyo Srinivasan Athertya
GKGurunathan Saravana Kumar
Gurunathan Saravana Kumar
Background and Objective: This article describes a fully automatic system for classifying various spinal degenerative phenotypes namely Modic changes, endplate defects and focal changes which are associated with lower back pain. These are obtained from T1/T2 Magnetic Resonance Imaging (MRI) scans. Lower back pain is a predominantly occurring ailment, which is prone to have various roots including the anatomical and pathophysciological aspects. Clinicians and radiologist use MRI to assess and evaluate the extent of damage, cause, and to decide on the future course of treatment. In large healthcare systems, to circumvent the manual reading of various image slices, we describe a system to automate the classification of various vertebral degeneracies that cause lower back pain. Methods: We implement a combination of feature extraction, image analysis based on geometry and classification using machine learning techniques for identifying vertebral degeneracies. Image features like local binary pattern, Hu’s moments and gray level co-occurrence matrix (GLCM) based features are extracted to identify Modic changes, endplate defects, and presence of any focal changes. A combination of feature set is used for describing the extent of Modic change on the end plate. Feature sensitivity studies towards efficient classification is presented. A STIR based acute/chronic classification is also attempted in the current work. Results: The implemented method is tested and validated over a dataset containing 100 patients. The proposed framework for detecting the extent of Modic change achieves an accuracy of 85.91%. From the feature sensitivity analysis, it is revealed that entropy based measure obtained from gray level co-occurrence matrix alone is sufficient for detection of focal changes. The classification performance for detecting endplate defect is highly sensitive to the first 2 Hu’s moments. Conclusion: A novel approach to identify the allied vertebral degenerations and extent of Modic changes in vertebrae by exploiting image features and classification through machine learning is proposed. This shall assist radiologists in detecting abnormalities and in treatment planning.

9 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
BMBhavsimran S Malhi
Bhavsimran S Malhi
DMDina Moazamian
Dina Moazamian
SSSoo Hyun Shin
Soo Hyun Shin
JAJiyo Srinivasan Athertya
Jiyo Srinivasan Athertya
LSLivia Silva
Livia Silva
Jiang DuJiang Du
Jiang Du
Introduction: The objective of this study was to assess the bi-exponential relaxation times and fractions of the short and long components of the human patellar tendon ex vivo using three-dimensional ultrashort echo time T1ρ (3D UTE-T1ρ) imaging. Materials and Methods: Five cadaveric human knee specimens were scanned using a 3D UTE-T1ρ imaging sequence on a 3T MR scanner. A series of 3D UTE-T1ρ images were acquired and fitted using single-component and bi-component models. Single-component exponential fitting was performed to measure the UTE-T1ρ value of the patellar tendon. Bi-component analysis was performed to measure the short and long UTE-T1ρ values and fractions. Results: The single-component analysis showed a mean single-component UTE-T1ρ value of 8.4 ± 1.7 ms for the five knee patellar tendon samples. Improved fitting was achieved with bi-component analysis, which showed a mean short UTE-T1ρ value of 5.5 ± 0.8 ms with a fraction of 77.6 ± 4.8%, and a mean long UTE-T1ρ value of 27.4 ± 3.8 ms with a fraction of 22.4 ± 4.8%. Conclusion: The 3D UTE-T1ρ sequence can detect the single- and bi-exponential decay in the patellar tendon. Bi-component fitting was superior to single-component fitting.

1 January 2025 in Journal of Neuroimaging
Verified
Journal Article
Closed access
JAJiyo Srinivasan Athertya
Jiyo Srinivasan Athertya
XCXin Cheng
Xin Cheng
QTQingbo Tang
Qingbo Tang
DMDina Moazamian
Dina Moazamian
ECEric Y. Chang
Eric Y. Chang
JDJiang Du
Jiang Du