Yajun Ma

Dr. Yajun Ma


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
MBMichal Byra
Michal Byra
MWMei Wu
Mei Wu
XZXiaodong Zhang
Xiaodong Zhang
HJHyungseok Jang
Hyungseok Jang
YMYajun Ma
Yajun Ma
Jiang DuJiang Du
Jiang Du

18 September 2020 in Frontiers in Endocrinology
Verified
Journal Article
Open access
YMYajun Ma
Yajun Ma
SJSaeed Jerban
Saeed Jerban
HJHyungseok Jang
Hyungseok Jang
DCDouglas Chang
Douglas Chang
ECEric Y. Chang
Eric Y. Chang
Jiang DuJiang Du
Jiang Du
Bone possesses a highly complex hierarchical structure comprised of mineral (~45% by volume), organic matrix (~35%) and water (~20%). Water exists in bone in two forms: as bound water (BW), which is bound to bone mineral and organic matrix, or as pore water (PW), which resides in Haversian canals as well as in lacunae and canaliculi. Magnetic resonance (MR) imaging has been increasingly used for assessment of cortical and trabecular bone. However, bone appears as a signal void on conventional MR sequences because of its short T2*. Ultrashort echo time (UTE) sequences with echo times (TEs) 100–1,000 times shorter than those of conventional sequences allow direct imaging of BW and PW in bone. A series of quantitative UTE MRI techniques has been developed for bone evaluation. UTE and adiabatic inversion recovery prepared UTE (IR-UTE) sequences have been developed to quantify BW and PW. UTE magnetization transfer (UTE-MT) sequences have been developed to quantify collagen backbone protons, and UTE quantitative susceptibility mapping (UTE-QSM) sequences have been developed to assess bone mineral.

11 August 2020 in Radiology
Verified
Journal Article
Closed access
YMYajun Ma
Yajun Ma
HJHyungseok Jang
Hyungseok Jang
ZWZhao Wei
Zhao Wei
ZCZhenyu Cai
Zhenyu Cai
YXYanping Xue
Yanping Xue
Jiang DuJiang Du
Jiang Du
A new three-dimensional short repetition time adiabatic inversion recovery–prepared ultrashort echo time sequence provided selective imaging of brain myelin with water signals efficiently suppresse... Background Water signal contamination is a major challenge for direct ultrashort echo time (UTE) imaging of myelin in vivo because water contributes most of the signals detected in white matter. Pu...

1 February 2020 in Radiology
Verified
Journal Article
Closed access
YMYajun Ma
Yajun Ma
ASAdam C. Searleman
Adam C. Searleman
HJHyungseok Jang
Hyungseok Jang
JWJonathan Wong
Jonathan Wong
ECEric Chang
Eric Chang
Jiang DuJiang Du
Jiang Du
Three-dimensional double-echo sliding inversion recovery ultrashort echo time MRI enables robust direct imaging of myelin confirmed via phantom, ex vivo, and in vivo studies; obvious myelin signal ... Background Signal contamination from long T2 water is a major challenge in direct imaging of myelin with MRI. Nulling of the unwanted long T2 signals can be achieved with an inversion recovery (IR)...


Verified
Journal Article
Open access
PDF file
ALAlecio Lombardi
Alecio Lombardi
YMYajun Ma
Yajun Ma
HJHyungseok Jang
Hyungseok Jang
SJSAEED JERBAN
SAEED JERBAN
QTQingbo Tang
Qingbo Tang
ECEric Chang
Eric Chang
A relationship between an acidic pH in the joints, osteoarthritis (OA), and pain has been previously demonstrated. Acidosis Chemical Exchange Saturation Transfer (acidoCEST) indirectly measures the extracellular pH through the assessment of the exchange of protons between amide groups on iodinated contrast agents and bulk water. It is possible to estimate the extracellular pH in the osteoarthritic joint using acidoCEST MRI. However, conventional MR sequences cannot image deep layers of cartilage, meniscus, ligaments, and other musculoskeletal tissues that present with short echo time and fast signal decay. Ultrashort echo time (UTE) MRI, on the other hand, has been used successfully to image those joint tissues. Here, our goal is to compare the pH measured in the knee joints of volunteers without OA and patients with severe OA using acidoCEST-UTE MRI. Patients without knee OA and patients with severe OA were examined using acidoCEST-UTE MRI and the mean pH of cartilage, meniscus, and fluid was calculated. Additionally, the relationship between the pH measurements and the Knee Injury and Osteoarthritis Outcome Score (KOOS) was investigated. AcidoCEST-UTE MRI can detect significant differences in the pH of knee cartilage, meniscus, and fluid between joints without and with OA, with OA showing lower pH values. In addition, symptoms and knee-joint function become worse at lower pH measurements.