Wenxi Chen

Prof. Wenxi Chen

Biomedical Information Technology Laboratory, The University of Aizu, Aizu-Wakamatsu, Japan
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
CLChuan-Bi Lin
Chuan-Bi Lin
YCYing Chen
Ying Chen
Wenxi ChenWenxi Chen
Wenxi Chen
THTai-Shen Huang
Tai-Shen Huang
CHChi-Yueh Hsu
Chi-Yueh Hsu
In recent years, wearable monitoring devices have been very popular in the health care field and are being used to avoid sport injuries during exercise. They are usually worn on the wrist, the same as sport watches, or on the chest, like an electrocardiogram patch. Common functions of these wearable devices are that they use real time to display the state of health of the body, and they are all small sized. The electromyogram (EMG) signal is usually used to show muscle activity. Thus, the EMG signal could be used to determine the muscle-fatigue conditions. In this study, the goal is to develop an EMG patch which could be worn on the lower leg, the gastrocnemius muscle, to detect real-time muscle fatigue while exercising. A micro controller unit (MCU) in the EMG patch is part of an ARM Cortex-M4 processor, which is used to measure the median frequency (MF) of an EMG signal in real time. When the muscle starts showing tiredness, the median frequency will shift to a low frequency. In order to delete the noise of the isotonic EMG signal, the EMG patch has to run the empirical mode decomposition algorithm. A two-electrode circuit was designed to measure the EMG signal. The maximum power consumption of the EMG patch was about 39.5 mAh. In order to verify that the real-time MF values measured by the EMG patch were close to the off-line MF values measured by the computer system, we used the root-mean-square value to estimate the difference in the real-time MF values and the off-line MF values. There were 20 participants that rode an exercise bicycle at different speeds. Their EMG signals were recorded with an EMG patch and a physiological measurement system at the same time. Every participant rode the exercise bicycle twice. The averaged root-mean-square values were 2.86 ± 0.86 Hz and 2.56 ± 0.47 Hz for the first and second time, respectively. Moreover, we also developed an application program implemented on a smart phone to display the participants’ muscle-fatigue conditions and information while exercising. Therefore, the EMG patch designed in this study could monitor the muscle-fatigue conditions to avoid sport injuries while exercising.

9 February 2019 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
Wenxi ChenWenxi Chen
Wenxi Chen

26 April 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SNS. M. Isuru Niroshana
S. M. Isuru Niroshana
XZXin Zhu
Xin Zhu
KNKeijiro Nakamura
Keijiro Nakamura
Wenxi ChenWenxi Chen
Wenxi Chen
Obstructive sleep apnea (OSA) is a common chronic sleep disorder that disrupts breathing during sleep and is associated with many other medical conditions, including hypertension, coronary heart disease, and depression. Clinically, the standard for diagnosing OSA involves nocturnal polysomnography (PSG). However, this requires expert human intervention and considerable time, which limits the availability of OSA diagnosis in public health sectors. Therefore, electrocardiogram (ECG)-based methods for OSA detection have been proposed to automate the polysomnography procedure and reduce its discomfort. So far, most of the proposed approaches rely on feature engineering, which calls for advanced expert knowledge and experience. This paper proposes a novel fused-image-based technique that detects OSA using only a single-lead ECG signal. In the proposed approach, a convolutional neural network extracts features automatically from images created with one-minute ECG segments. The proposed network comprises 37 layers, including four residual blocks, a dense layer, a dropout layer, and a soft-max layer. In this study, three time–frequency representations, namely the scalogram, the spectrogram, and the Wigner–Ville distribution, were used to investigate the effectiveness of the fused-image-based approach. We found that blending scalogram and spectrogram images further improved the system’s discriminative characteristics. Seventy ECG recordings from the PhysioNet Apnea-ECG database were used to train and evaluate the proposed model using 10-fold cross validation. The results of this study demonstrated that the proposed classifier can perform OSA detection with an average accuracy, recall, and specificity of 92.4%, 92.3%, and 92.6%, respectively, for the fused spectral images.

3 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
RLRen-Xuan Li
Ren-Xuan Li
Jia-Jung WangJia-Jung Wang
Jia-Jung Wang
Wenxi ChenWenxi Chen
Wenxi Chen
CSChun-Hung Su
Chun-Hung Su
As photoplethysmographic (PPG) signals are comprised of numerous pieces of important physiological information, they have been widely employed to measure many physiological parameters. However, only a high-quality PPG signal can provide a reliable physiological assessment. Unfortunately, PPG signals are easily corrupted by motion artifacts and baseline drift during recording. Although several rule-based algorithms have been developed for evaluating the quality of PPG signals, few artificial intelligence-based algorithms have been presented. Thus, this study aims to classify the quality of PPG signals by using two two-dimensional deep convolution neural networks (DCNN) when the PPG pulse is used to measure cardiac stroke volume (SV) by impedance cardiography. An image derived from a PPG pulse and its differential pulse is used as the input to the two DCNN models. To quantify the quality of individual PPG pulses, the error percentage of the beat-to-beat SV measured by our device and medis® CS 2000 synchronously is used to determine whether the pulse quality is high, middle, or low. Fourteen subjects were recruited, and a total of 3135 PPG pulses (1342 high quality, 73 middle quality, and 1720 low quality) were obtained. We used a traditional DCNN, VGG-19, and a residual DCNN, ResNet-50, to determine the quality levels of the PPG pulses. Their results were all better than the previous rule-based methods. The accuracies of VGG-19 and ResNet-50 were 0.895 and 0.925, respectively. Thus, the proposed DCNN may be applied for the classification of PPG quality and be helpful for improving the SV measurement in impedance cardiography.

1 April 2005 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
Wenxi ChenWenxi Chen
Wenxi Chen
XZXin Zhu
Xin Zhu
TNT. Nemoto
T. Nemoto
YKY. Kanemitsu
Y. Kanemitsu
KKK. Kitamura
K. Kitamura
KYK. Yamakoshi
K. Yamakoshi

21 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
Jia-Jung WangJia-Jung Wang
Jia-Jung Wang
Wenxi ChenWenxi Chen
Wenxi Chen
KPKuo-Li Pan
Kuo-Li Pan
CSChun-Hung Su
Chun-Hung Su
Photoplethysmography (PPG) has been extensively employed to acquire some physiological parameters such as heart rate, oxygen saturation, and blood pressure. However, PPG signals are frequently corrupted by motion artifacts and baseline wandering, especially for the reflective PPG sensor. Several different algorithms have been studied for determining the signal quality of PPG by the characteristic parameters of its waveform and the rule-based methods. The levels of signal quality usually were defined by the manual operations. Thus, whether the good PPG waveforms are enough to increase the accuracy of the measurement is still a subjective issue. The aim of this study is to use a fuzzy neural network to determine the signal quality indexes (SQI) of PPG pulses measured by the impedance cardiography. To test the algorithm performance, the beat-to-beat stroke volumes (SV) were measured with our device and the medis® CS 2000, synchronously. A total of 1466 pulses from 10 subjects were used to validate our algorithm in which the SQIs of 1007 pulses were high, those of 71 pulses were in the middle, and those of 388 pulses were low. The total error of SV measurement was −18 ± 22.0 mL. The performances of the classification were that the sensitivity and specificity for the 1007 pulses with the high SQIs were 0.81 and 0.90, and the error of SV measurement was 6.4 ± 12.8 mL. The sensitivity and specificity for the 388 pulses with the low SQIs were 0.84 and 0.93, while the error of SV measurement was 30.4 ± 3.6 mL. The results show that the proposed algorithm could be helpful in choosing good-quality PPG pulses to increase the accuracy of SV measurement in the impedance plethysmography.