Elena De Ponti

Dr. Elena De Ponti


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
PFPaolo Niccolò Franco
Paolo Niccolò Franco
CSChiara Maria Spasiano
Chiara Maria Spasiano
CMCesare Maino
Cesare Maino
EPElena De Ponti
Elena De Ponti
MRMaria Ragusi
Maria Ragusi
DIDavide Ippolito
Davide Ippolito
The advance in technology allows for the development of different CT scanners in the field of dual-energy computed tomography (DECT). In particular, a recently developed detector-based technology can collect data from different energy levels, thanks to its layers. The use of this system is suited for material decomposition with perfect spatial and temporal registration. Thanks to post-processing techniques, these scanners can generate conventional, material decomposition (including virtual non-contrast (VNC), iodine maps, Z-effective imaging, and uric acid pair images) and virtual monoenergetic images (VMIs). In recent years, different studies have been published regarding the use of DECT in clinical practice. On these bases, considering that different papers have been published using the DECT technology, a review regarding its clinical application can be useful. We focused on the usefulness of DECT technology in gastrointestinal imaging, where DECT plays an important role.

1 March 2019 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
GCGabriele Canzi
Gabriele Canzi
EPElena De Ponti
Elena De Ponti
Giorgio NovelliGiorgio Novelli
Giorgio Novelli
FMFabio Mazzoleni
Fabio Mazzoleni
OCOsvaldo Chiara
Osvaldo Chiara
DSDavide Sozzi
Davide Sozzi

Verified
Journal Article
Open access
PDF file
DSDavide Sozzi
Davide Sozzi
Andrea FilippiAndrea Filippi
Andrea Filippi
GCGabriele Canzi
Gabriele Canzi
EPElena De Ponti
Elena De Ponti
ABAlberto Bozzetti
Alberto Bozzetti
Giorgio NovelliGiorgio Novelli
Giorgio Novelli
Aim: the purpose of this work is to present an innovative protocol for virtual planning and surgical navigation in post-oncological mandibular reconstruction through fibula free flap. In order to analyze its applicability, an evaluation of accuracy for the surgical protocol has been performed. Methods: 21 patients surgically treated for mandibular neoplasm have been included in the analysis. The Brainlab Vector Vision 3.0® software for surgical navigation has been used for preoperative surgical planning and intra-operative navigation. A post-operative accuracy evaluation has been performed matching the position of mandibular landmarks between pre-operative and post-operative CT scans. Results: the maximal discrepancy observed was included between −3.4 mm and +3.2 mm, assuming negative values for under correction and positive values for overcorrection. An average grade of accuracy included between 0.06 ± 0.58 mm and 0.43 ± 0.68 mm has been observed for every mandibular landmark examined, except for mandibular angles that showed a mean discrepancy value included between 1.36 ± 1.73 mm and 1.46 ± 1.02 mm when compared to preoperative measurements. Conclusion: a satisfying level of accuracy has been observed in the protocol presented, which appears to be more versatile if compared to closed custom-made systems. The technique described may represent a valid option for selected patients, but it cannot be considered for routine activity because of the complexity of the method, the mobility of the jaw, the necessity of surgical navigator and the long surgical learning curve that is required.

10 February 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Valeria FaccendaValeria Faccenda
Valeria Faccenda
Denis PanizzaDenis Panizza
Denis Panizza
MDMartina Camilla Daniotti
Martina Camilla Daniotti
RPRoberto Giuseppe Pellegrini
Roberto Giuseppe Pellegrini
STSara Trivellato
Sara Trivellato
SASTEFANO ARCANGELI
STEFANO ARCANGELI
The dosimetric impact of intrafraction prostate motion and interfraction anatomical changes and the effect of beam gating and motion correction were investigated in dose-escalated linac-based SBRT. Fifty-six gated fractions were delivered using a novel electromagnetic tracking device with a 2 mm threshold. Real-time prostate motion data were incorporated into the patient’s original plan with an isocenter shift method. Delivered dose distributions were obtained by recalculating these motion-encoded plans on deformed CTs reflecting the patient’s CBCT daily anatomy. Non-gated treatments were simulated using the prostate motion data assuming that no treatment interruptions have occurred. The mean relative dose differences between delivered and planned treatments were −3.0% [−18.5–2.8] for CTV D99% and −2.6% [−17.8–1.0] for PTV D95%. The median cumulative CTV coverage with 93% of the prescribed dose was satisfactory. Urethra sparing was slightly degraded, with the maximum dose increased by only 1.0% on average, and a mean reduction in the rectum and bladder doses was seen in almost all dose metrics. Intrafraction prostate motion marginally contributed in gated treatments, while in non-gated treatments, further deteriorations in the minimum target coverage and bladder dose metrics would have occurred on average. The implemented motion management strategy and the strict patient preparation regimen, along with other treatment optimization strategies, ensured no significant degradations of dose metrics in delivered treatments.

1 September 2019 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
GCGabriele Canzi
Gabriele Canzi
EPElena De Ponti
Elena De Ponti
CFChiara Fossati
Chiara Fossati
Giorgio NovelliGiorgio Novelli
Giorgio Novelli
Stefania CimbanassiStefania Cimbanassi
Stefania Cimbanassi
DSDavide Sozzi
Davide Sozzi

30 March 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Alessandro BudaAlessandro Buda
Alessandro Buda
CPCristiana Paniga
Cristiana Paniga
STSalih Taskin
Salih Taskin
MMMichael Mueller
Michael Mueller
Ignacio ZapardielIgnacio Zapardiel
Ignacio Zapardiel
RFRobert Fruscio
Robert Fruscio
The aim of this study was to assess the impact of low-volume metastasis (LVM) on disease-free survival (DFS) in women with apparent early-stage endometrial cancer (EC) who underwent sentinel lymph node (SLN) mapping. Patients with pre-operative early-stage EC were retrospectively collected from an international collaboration including 13 referring institutions. A total of 1428 patients were included in this analysis. One hundred and eighty-six patients (13%) had lymph node involvement. Fifty-nine percent of positive SLN exhibited micrometastases, 26.9% micrometastases, and 14% isolated tumor cells. Seventeen patients with positive lymph nodes did not receive any adjuvant therapy. At a median follow-up of 33.3 months, the disease had recurred in 114 women (8%). Patients with micrometastases in the lymph nodes had a worse prognosis of disease-free survival compared to patients with negative nodes or LVM. The rate of recurrence was significantly higher for women with micrometastases than those with low-volume metastases (HR = 2.61; p = 0.01). The administration of adjuvant treatment in patients with LVM, without uterine risk factors, remains a matter of debate and requires further evaluation.