Accurate acquisition of dynamic load allowance (DLA) based on measurement data is essential to the safety assessment of a bridge. When static load tests cannot be achieved, and filtering fails, the estimated DLAs from the experimental method vary widely due to the choice of a left or right band. In this paper, the proposed weighted average method (WAM) is used to possibly solve the above problem in continuous gird bridges. Two-span and three-span precast concrete box-gird bridges were selected to optimize intercepted segments of WAM for the first time with the assistance of standard deviation and coefficient of variation in statistics. Then, a DLA measurement case of the negative bending moment was utilized to verify the validity of the WAM. The results show that the intercepted segments of 10/16 to 1 times the span length were suitable for the WAM to calculate the DLA of the negative bending moment due to small offset moments and stable variation coefficients. The WAM had a strong anti-interference ability of outliers filtering in “bad data,” which differed significantly from the experimental method. In three measurements of a field bridge, DLAs obtained by the WAM had less dispersion than the experimental and low-pass filtering methods.
Several single-column pier girder bridges have been involved in overturning accidents, resulting in significant economic losses and casualties, thus necessitating a risk assessment of the overturning stability. To date, the effect of structural degradation due to concrete creep on the long-term stability of bridges has not been demonstrated. In this study, a full-scale nonlinear analysis of the lateral overturning process of a collapsed concrete box girder based on the explicit dynamic finite element method (EFEM) was conducted to verify the reliability of the numerical method. An EFEM model incorporating concrete creep was developed to demonstrate the effect of structural degradation on the long-term stability of bridges. The synthesis overturning axis method (SOAM) was proposed to evaluate the long-term overturning stability of concrete continuous bridges, aiming to address the deficiencies in existing methods, particularly for curved bridges, and was compared with conventional methods. The results show that the variations in bearing reaction forces between curved and straight bridges under creep and self-weight are minimal, staying within 2%. An increase in the creep terminal coefficient results in the opposite trend in the ultimate vehicle weight of curved bridges and straight bridges, but fluctuations remain within 2%, indicating that long-term creep has a limited effect on the overall overturning stability. A failure analysis of 20 single-column pier bridges reveals significant differences in the ultimate vehicle weight between the rigid overturning axis method (ROAM) and folded overturning axis method (FOAM), with error ranges of −14.2% to 567.4% and −99.1% to −32.1%, respectively. The SOAM results have the smallest error range compared to those of the EFEM, with an error range of −38.8% to 33.9%. Despite these errors, the SOAM demonstrates a significant improvement in characterizing the trend and assessment accuracy of the overall overturning stability of single-column pier bridges.
As a typical industrial solid waste-based concrete material, activated coal gangue cementitious concrete is prone to the freeze-thaw cycle in cold-region engineering applications, leading to durability degradation that severely limits its service performance. In this paper, freeze-thaw cycle tests were designed to reveal the influence of different ratio designs on the freeze resistance of materials. Scanning electron microscopy and nuclear magnetic resonance spectroscopy were employed to observe the microstructural changes in the internal pores of activated coal gangue cementitious concrete after freeze-thaw degradation. The optimal replacement ratio for activated coal gangue powder was analyzed. The results showed that, as the number of freeze-thaw cycles increased, the pore structure within the activated coal gangue cemented concrete deteriorated significantly, though the degree of deterioration varied. With the gangue powder content increasing, both the number of pores and porosity within the concrete initially decrease and then increase. According to the test results, when the activated coal gangue powder content was 35% in the concrete mix, the freeze-thaw resistance performance was optimal. This mixture maintained a good pore structure and superior porosity, indicating that the concrete with 35% activated coal gangue powder content was the best mix design. The result provides a reference for enhancing the freeze-thaw resistance of activated coal gangue cementitious concrete in cold environments.