Begum Tokay

Dr. Begum Tokay

Associate Professor, Faculty of Engineering, Nottingham University, Nottingham, UK

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Separation and Purification Technology
Verified
Journal Article
Closed access
SMSrabani Majumdar
Srabani Majumdar
Begum TokayBegum Tokay
Begum Tokay
VMVioleta Martin-Gil
Violeta Martin-Gil
JCJames Campbell
James Campbell
Roberto Castro-MuñozRoberto Castro-Muñoz
Roberto Castro-Muñoz
VFVlastimil Fila
Vlastimil Fila

1 November 2010 in Journal of Membrane Science
Verified
Journal Article
Closed access
YZYanfeng Zhang
Yanfeng Zhang
Begum TokayBegum Tokay
Begum Tokay
HFHans H. Funke
Hans H. Funke
JFJohn L. Falconer
John L. Falconer
RNRichard D. Noble
Richard D. Noble

1 December 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
JHJiri Hromadka
Jiri Hromadka
Begum TokayBegum Tokay
Begum Tokay
SJStephen James
Stephen James
RTRalph P Tatam
Ralph P Tatam
Sergiy KorposhSergiy Korposh
Sergiy Korposh
An optical fibre long period grating (LPG) modified with a thin film of ZIF-8, zeolitic immidazol framework material, a subgroup of metal organic framework (MOF) family, was employed for the detection of organic vapours. ZIF-8 film was deposited onto the surface of the LPG using in-situ crystallization technique by mixing freshly prepared 12.5 mM zinc nitrate hexahydrate and 25 mM of 2-metyl-imidazole solutions in methanol. ZIF-8 film was characterized by scanning electron microscope (SEM) images, thickness and refractive index (RI) has been calculated with use of ellipsometer for films containing of 1,2,3,5 and 10 growth cycles. The crystallinity of the film was confirmed by x-ray diffraction pattern (XRD). The LPG sensor was designed to operate at the phase matching turning point to provide the highest sensitivity. The sensing mechanism is based on the measurement of the RI change induced by the penetration of the chemical molecules into the ZIF-8 pores. LPG modified with 2 and 5 growth cycles of ZIF-8 responded to exposure to methanol, ethanol, 2-propanol and acetone. The sensitivity of the measurements to humidity as an interfering parameter was also investigated

15 August 2010 in Journal of Membrane Science
Verified
Journal Article
Closed access
YZYanfeng Zhang
Yanfeng Zhang
AAAdolfo M. Avila
Adolfo M. Avila
Begum TokayBegum Tokay
Begum Tokay
HFHans H. Funke
Hans H. Funke
JFJohn L. Falconer
John L. Falconer
RNRichard D. Noble
Richard D. Noble

1 October 2017 in Microporous and Mesoporous Materials
Verified
Journal Article
Closed access
JCJames Campbell
James Campbell
Begum TokayBegum Tokay
Begum Tokay

22 December 2020 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
EAElvin Aliyev
Elvin Aliyev
JWJan Warfsmann
Jan Warfsmann
Begum TokayBegum Tokay
Begum Tokay
Sergey ShishatskiySergey Shishatskiy
Sergey Shishatskiy
YLYoung-Joo Lee
Young-Joo Lee
Volkan FilizVolkan Filiz
Volkan Filiz