Gary E Christensen

Prof. Gary E Christensen

University of Iowa, Iowa City, Iowa, USA
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2001 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GCGary E Christensen
Gary E Christensen
HJH.J. Johnson
H.J. Johnson
Presents a new method for image registration based on jointly estimating the forward and reverse transformations between two images while constraining these transforms to be inverses of one another. This approach produces a consistent set of transformations that have less pairwise registration error, i.e., better correspondence, than traditional methods that estimate the forward and reverse transformations independently. The transformations are estimated iteratively and are restricted to preserve topology by constraining them to obey the laws of continuum mechanics. The transformations are parameterized by a Fourier series to diagonalize the covariance structure imposed by the continuum mechanics constraints and to provide a computationally efficient numerical implementation. Results using a linear elastic material constraint are presented using both magnetic resonance and X-ray computed tomography image data. The results show that the joint estimation of a consistent set of forward and reverse transformations constrained by linear-elasticity give better registration results than using either constraint alone or none at all.

1 January 1997 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GCGary E Christensen
Gary E Christensen
SJS.C. Joshi
S.C. Joshi
MMM.I. Miller
M.I. Miller
Presents diffeomorphic transformations of three-dimensional (3-D) anatomical image data of the macaque occipital lobe and whole brain cryosection imagery and of deep brain structures in human brains as imaged via magnetic resonance imagery. These transformations are generated in a hierarchical manner, accommodating both global and local anatomical detail. The initial low-dimensional registration is accomplished by constraining the transformation to be in a low-dimensional basis. The basis is defined by the Green's function of the elasticity operator placed at predefined locations in the anatomy and the eigenfunctions of the elasticity operator. The high-dimensional large deformations are vector fields generated via the mismatch between the template and target-image volumes constrained to be the solution of a Navier-Stokes fluid model. As part of this procedure, the Jacobian of the transformation is tracked, insuring the generation of diffeomorphisms. It is shown that transformations constrained by quadratic regularization methods such as the Laplacian, biharmonic, and linear elasticity models, do not ensure that the transformation maintains topology and, therefore, must only be used for coarse global registration.

10 August 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SGSarah Gerard
Sarah Gerard
TPTaylor J. Patton
Taylor J. Patton
GCGary E Christensen
Gary E Christensen
JBJohn E. Bayouth
John E. Bayouth
JRJoseph M. Reinhardt
Joseph M. Reinhardt
Pulmonary fissure detection in computed tomography (CT) is a critical component for automatic lobar segmentation. The majority of fissure detection methods use feature descriptors that are hand-crafted, low-level, and have local spatial extent. The design of such feature detectors is typically targeted towards normal fissure anatomy, yielding low sensitivity to weak and abnormal fissures that are common in clinical datasets. Furthermore, local features commonly suffer from low specificity, as the complex textures in the lung can be indistinguishable from the fissure when global context is not considered. We propose a supervised discriminative learning framework for simultaneous feature extraction and classification. The proposed framework, called FissureNet, is a coarse-to-fine cascade of two convolutional neural networks. The coarse-to-fine strategy alleviates the challenges associated with training a network to segment a thin structure that represents a small fraction of the image voxels. FissureNet was evaluated on a cohort of 3706 subjects with inspiration and expiration 3DCT scans from the COPDGene clinical trial and a cohort of 20 subjects with 4DCT scans from a lung cancer clinical trial. On both datasets, FissureNet showed superior performance compared to a deep learning approach using the U-Net architecture and a Hessian-based fissure detection method in terms of area under the precisionrecall curve (PR-AUC). The overall PR-AUC for FissureNet, UNet, and Hessian on the COPDGene (lung cancer) dataset was 0.980 (0.966), 0.963 (0.937), and 0.158 (0.182), respectively. On a subset of 30 COPDGene scans, FissureNet was compared to a recently proposed advanced fissure detection method called derivative of sticks (DoS) and showed superior performance with a PR-AUC of 0.991 compared to 0.668 for DoS.

21 May 2007 in Medical Physics
Verified
Journal Article
Closed access
GCGary E Christensen
Gary E Christensen
JSJoo Hyun Song
Joo Hyun Song
WLWei Lu
Wei Lu
INIssam El Naqa
Issam El Naqa
DLDaniel A. Low
Daniel A. Low

19 October 2021 in Radiology
Verified
Journal Article
Open access
NBNicholas Burris
Nicholas Burris
ZBZhangxing Bian
Zhangxing Bian
JDJeffrey Dominic
Jeffrey Dominic
JZJianyang Zhong
Jianyang Zhong
IHIgnas B. Houben
Ignas B. Houben
CHCharles R. Hatt
Charles R. Hatt
Vascular deformation mapping, a deformable image registration-based technique, enabled reliable comprehensive assessment of the degree and extent of three-dimensional growth among patients with a t... Background Aortic diameter measurements in patients with a thoracic aortic aneurysm (TAA) show wide variation. There is no technique to quantify aortic growth in a three-dimensional (3D) manner. Pu...

1 August 2006 in NeuroImage
Verified
Journal Article
Closed access
GCGary E Christensen
Gary E Christensen
HJHans J. Johnson
Hans J. Johnson
MVMichael W Vannier
Michael W Vannier