Nehmdoh Sabiha

Prof. Dr. Nehmdoh Sabiha

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
NSNehmdoh Sabiha
Nehmdoh Sabiha
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
ITIbrahim B. M. Taha
Ibrahim B. M. Taha
While much attention was given in the literature to improve the fault ride through (FRT) capability of a doubly-fed induction generator (DFIG)-based wind energy conversion system (WECS) during various faults at the grid side, not much attention was given to investigate and improve the performance of the DFIG-WECS under ferroresonance conditions. This paper investigates the impact of ferroresonance on the overall performance of a DFIG-WECS. The paper also presents a new technique to improve the high voltage ride through capability of the investigated system under such condition. The proposed technique relies on incorporating a superconducting coil within the dc-link of the DFIG grid-side and rotor-side converters. Energy exchange between the coil and the system is controlled through regulating the duty cycle of the dc-chopper interfacing the coil with the dc-link. In this regard, a simple but yet effective proportional-integral (PI) controller is employed to regulate the dc-chopper duty cycle. Parameters of the PI controller are optimized using elephant herding optimization algorithm. Simulation results verify the effectiveness of the proposed controller in improving the overall performance of a DFIG-WECS during ferroresonance events.

1 September 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
NSNehmdoh Sabiha
Nehmdoh Sabiha
MAMohammad Alsharef
Mohammad Alsharef
Mohamed K. MetwalyMohamed K. Metwaly
Mohamed K. Metwaly
EEEhab E. Elattar
Ehab E. Elattar
Ibrahim B. M. TahaIbrahim B. M. Taha
Ibrahim B. M. Taha
AAAmr M. Abd-Elhady
Amr M. Abd-Elhady

1 July 2019 in IET Science, Measurement & Technology
Verified
Journal Article
Closed access
NSNehmdoh Sabiha
Nehmdoh Sabiha
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
MHMahmoud M. Hessien
Mahmoud M. Hessien
In this study, newly structured nanoparticles are synthesised and incorporated in the transformer oil for enhancing the dielectric properties. A new nanocrystalline series of zinc oxide (ZnO) and ZnO partially substituted by lanthanum oxide is presented for the first time, where the precursor technique is utilised to create the nano‐powders. Different partial substitutions facilitate to manipulate nanocrystalline sizes, and therefore the effect on nanofluid dielectric characteristics is attained. Another factor during the laboratory nanoparticles preparation is considered that the precursor is annealed at different temperatures. The nanocrystalline phase compositions are experimentally examined and evaluated using X‐ray diffraction and transmission electron microscope. Accordingly, single‐phase and multi‐phase nanocrystalline powders are ascertained. The transformer oil incorporated with nanoparticles is prepared and its dielectric strength is measured using an oil breakdown voltage tester. The measured dielectric strength of transformer oil with and without nanoparticles is statistically evaluated using Weibull distribution. The most appropriate nanofluid and concentration are estimated experimentally. Toward interpreting the nanofluid dielectric enhancement, their electric field distribution is numerically evaluated at different nanoparticle concentrations using COMSOL multiphysics. This study supports the analysis and optimisation of transformer oil dielectric performance.

2 December 2020 in IEEE Access
Verified
Journal Article
Open access
NSNehmdoh Sabiha
Nehmdoh Sabiha
FMFarhan Mahmood
Farhan Mahmood
AAAmr M. Abd-Elhady
Amr M. Abd-Elhady
Surge arresters are usually used to protect distribution feeders against randomly distributed lightning overvoltages. However, there is a probability of surge arrester failure due to an increase in its absorbed energy over the withstand capability. This paper experimentally and theoretically evaluates the application of a compound overvoltage protection scheme to avoid this failure. The compound overvoltage protection consists of an installed spark gap in parallel with an existing surge arrester to limit the risk of surge arrester failure. The experimental evaluation is performed by applying standard lightning impulse voltage waveform, 1.2/50 μs according to IEC Standard 60060-1. The evaluation is carried out without and with sparkgap adjusted at different lengths. The energy stress of the surge arrester with and without sparkgap is theoretically carried out using the ATP/EMTP software considering an overhead distribution feeder. The statistical evaluation for the failure risk assessment is performed using the MATLAB software. The results indicate that the installation of the spark gap in parallel with the surge arrester relieves the thermal stress on the surge arrester, and thus eliminates any risk of surge arrester failure using the proposed coordination.

9 September 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
NSNehmdoh Sabiha
Nehmdoh Sabiha
This study introduces an arrangement of surge arrester, Rogowski coil, and triac to attain service continuity of distribution networks. This new arrangement is proposed to limit the arrester failure due to lightning flashes striking distribution feeders. The arrester failure is probably happened due to the increase of absorbed energy over the withstand capability. As the lightning flash has multiple discharges, an equivalent single wave model is computed to evaluate the arrester discharge energy. The arrester discharge current is monitored using a single Rogowski coil. Then, the arrester's dynamic characteristic (current–voltage) is utilised to estimate the discharge energy using only the arrester current. The arrester and associated Rogowski coil are distributed in an 11 kV distribution network. Due to travelling‐waves reflections of the direct lightning striking the distribution feeder, the discharge energy of the installed arresters in the network is different than the computed energy using the lightning flash current as an impulse current source directly applied on the arrester device. Finally, the parallel triac with the arrester is suggested and triggered for limiting the arrester's failure. The detailed model of this proposed arrangement is evaluated via an electromagnetic simulation software. The failure assessment is statistically evaluated using the MATLAB software.

1 March 2021 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
NSNehmdoh Sabiha
Nehmdoh Sabiha
MAMohammad Alsharef
Mohammad Alsharef
ITIbrahim B.M. Taha
Ibrahim B.M. Taha
EEEhab E. Elattar
Ehab E. Elattar
Mohamed K. MetwalyMohamed K. Metwaly
Mohamed K. Metwaly
AAAmr M. Abd-Elhady
Amr M. Abd-Elhady