Johann Jacoby

Dr. Johann Jacoby


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Radiology
Verified
Journal Article
Closed access
HAHaidara Almansour
Haidara Almansour
JHJudith Herrmann
Judith Herrmann
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
Saif AfatSaif Afat
Saif Afat
JJJohann Jacoby
Johann Jacoby
A(Ahmed Othman (MD)
Ahmed Othman (MD)
Deep learning–reconstructed turbo spin-echo (TSE) acquisition was interchangeable with standard TSE for detecting various spinal abnormalities at MRI, providing excellent quality and a 70% reductio... Background Deep learning (DL)–based MRI reconstructions can reduce examination times for turbo spin-echo (TSE) acquisitions. Studies that prospectively employ DL-based reconstructions of rapidly ac...

19 November 2024 in Diagnostic and Interventional Imaging
Verified
Journal Article
Open access
JBJan Michael Brendel
Jan Michael Brendel
JJJohann Jacoby
Johann Jacoby
RDReza Dehdab
Reza Dehdab
JHJudith Herrmann
Judith Herrmann
SUStephan Ursprung
Stephan Ursprung
HAHaidara Almansour
Haidara Almansour
The purpose of this study was to compare a conventional T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence with a DL-reconstructed accelerated high-resolution VIBE sequence (HR-VIBEDL) in terms of image quality, lesion conspicuity, and lesion detection. Consecutive patients referred for upper abdominal MRI between December 2023 and March 2024 at a single tertiary center were prospectively enrolled. Participants underwent 1.5 T upper abdominal MRI with acquisition of spectrally fat-saturated unenhanced and gadobutrol-enhanced conventional VIBE (fourfold acceleration, 3.0 mm slice thickness, 72 axial slices) and HR-VIBEDL (sixfold acceleration, 2.0 mm, 108 slices). Both sequences had an identical acquisition time of 16 s. Image analysis was performed by three readers in a blinded and randomized fashion, with respect to image quality, lesion conspicuity, and lesion detection in liver, pancreas, spleen, lymph nodes and adrenal glands. Image quality parameters were compared using repeated measures analysis of variance. Lesion detection rates were compared using Fisher exact test. Inter-reader agreement was assessed using Fleiss κ test. Among 744 consecutive patients, 50 participants were evaluated. There were 30 men and 20 women, with a mean age of 60 ± 15 (standard deviation [SD]) years (age range: 18-88 years). HR-VIBEDL images demonstrated superior signal-to-noise ration and edge sharpness by comparison with conventional VIBE images (P < 0.001 for both), with substantial interreader agreement (κ: 0.70-0.90). Lesion conspicuity was higher with for HR-VIBEDL images (3.50 ± 0.83 [SD]) by comparison with conventional VIBE images (3.21 ± 0.98 [SD]) (P = 0.005). There were 171 upper abdominal lesions, yielding a total of 513 for all three readers. HR-VIBEDL images yielded higher lesion detection rate (97.5 %; 500/513) compared to conventional VIBE images (93.2 %; 478/513) (P = 0.002). HR-VIBEDL images of the upper abdomen result in superior image quality, better lesion conspicuity, and improved lesion detection without time penalty by comparsion with conventional VIBE images.

Verified
Journal Article
Open access
PDF file
HAHaidara Almansour
Haidara Almansour
JJJohann Jacoby
Johann Jacoby
HBHeiko Baumgartner
Heiko Baumgartner
MRMarie K. Reumann
Marie K. Reumann
KNKonstantin Nikolaou
Konstantin Nikolaou
FSFabian Springer
Fabian Springer
The tibial nutrient artery (TNA) is the major diaphyseal artery of the tibia supplying two thirds of the inner osseous cortex. Hence, iatrogenic injury of the TNA endangers the integrity of the tibial blood supply and may compromise fracture healing. The incidence of its injury in the setting of external fixation for lower limb fractures has not been previously investigated. The aim of this study was to evaluate the incidence of TNA injury in the context of external fixation and to characterize the topography of the fixator pins in relation to the TNA canal (TNAC). Patients who underwent external fixation for distal femoral fractures and for tibial (proximal, shaft, and distal) fractures and had a postoperative computed tomography study were retrospectively included. The following parameters were retrieved: 1) Pin characteristics (orientation and cortical position of the pins), 2) The anatomic relationship between the TNAC and external fixation pin (topography above/below and at the level of the TNAC, and the distance between the pin and medial tibial plateau and/or the medial malleolus), and 3) The incidence of TNAC injury (complete/partial disruption of TNA lumen). A total of 105 patients with 214 tibial pins were analyzed. In 27 patients (26%), the TNAC was completely injured by the pins of the external fixator. In 13 patients (12%), the TNAC was partially injured. Of the 214 analyzed pins, 85 pins (40%) were located at the level of the TNAC (the TNAC and the pin are seen on the same axial slice). Most pins that were applied at the level of the TNAC belonged to a knee-bridging external fixator. Of those, ninety-three percent of the pins were anteromedially applied according to published surgical guidelines. Six percent of the pins were applied through the tibial crest and 1% anterolaterally. Of those 85 pins, 42 pins (49%) injured the TNAC at least partially. Based on the analyzed pins and the incidence of partial and complete injury of the TNAC, we observed that the tibial segment at which the tibial nutrient artery is endangered was located approximately (95% CI: 13–15 cm) from the medial tibia plateau and (95% CI: 22–25 cm) from the medial malleolus. Thus, TNAC injury by external fixation pins in the context of lower limb fractures can be considered common. Almost half of the pins applied at the middle third of the tibia injured the TNA, despite adherence to published surgical guidelines for external fixation. When possible, pin application at the middle third of tibia should be avoided to circumvent iatrogenic injury of the TNA and to safeguard tibial blood supply.

23 August 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MWMatthias Weissinger
Matthias Weissinger
SKStefan Kommoss
Stefan Kommoss
JJJohann Jacoby
Johann Jacoby
SUStephan Ursprung
Stephan Ursprung
FSFerdinand Seith
Ferdinand Seith
HDHelmut Dittmann
Helmut Dittmann
[18F]FDG PET/MRI was shown to have limited sensitivity for N-staging in FIGO I/II cervical carcinoma. Therefore, this prospective study aimed to investigate the additional value of multiparametric dual-time-point PET/MRI and to assess potential influencing factors for lymph node metastasis (LNM) detection. A total of 63 patients underwent whole-body dual-time-point [18F]FDG PET/MRI 60 + 90 min p.i., and 251 LN were evaluated visually, quantified multiparametrically, and correlated with histology. Grading of the primary tumor (G2/G3) had a significant impact on visual detection (sens: 8.3%/31%). The best single parameter for LNM detection was SUVavg, however, with a significant loss of discriminatory power in G2 vs. G3 tumors (AUC: 0.673/0.901). The independent predictors SUVavg, ∆SUVpeak, LN sphericity, ADC, and histologic grade were included in the logistic-regression-based malignancy score (MS) for multiparametric analysis. Application of MS enhanced AUCs, especially in G2 tumors (AUC: G2:0.769; G3:0.877) and improved the accuracy for single LNM from 34.5% to 55.5% compared with the best univariate parameter SUVavg. Compared with visual analysis, the use of the malignancy score increased the overall sensitivity from 31.0% to 79.3% (Youden optimum) with a moderate decrease in specificity from 98.3% to 75.6%. These findings indicate that multiparametric evaluation of dual-time-point PET/MRI has the potential to improve accuracy compared with visual interpretation and enables sufficient N-staging also in G2 cervical carcinoma.

28 August 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
JKJens Kübler
Jens Kübler
PMPetros Martirosian
Petros Martirosian
JJJohann Jacoby
Johann Jacoby
GGGeorg Gohla
Georg Gohla
MWMoritz T. Winkelmann
Moritz T. Winkelmann
RHRüdiger Hoffmann
Rüdiger Hoffmann
Purpose: To evaluate the transient artifact augmentation of microtubes in magnetic resonance imaging by fluid injection.Methods: Twenty‐one fluorinated ethylene propylene catheters (inner diameter 760 μm) were filled with three different contrast media at various concentrations (Ferucarbotran, Resovist®, Bayer Schering Pharma; Manganese dichloride, MnCl2, Sigma‐Aldrich; Gadobutrol, Gadovist®, Bayer Schering Pharma). Artifact appearance was determined in an ex vivo phantom at 1.5 T using three different sequences: T1‐weighted three‐dimensional volume interpolated breath‐hold examination, T2‐weighted turbo spin echo, and T1‐weighted fast low angle shot. Catheter angulation to the main magnetic field (B0) was varied. Influence of parameters on artifact diameters was assessed with a multiple linear regression similar to an analysis of variance.Results: Artifact diameter was significantly influenced by the contrast agent (p < 0.001), concentration of the contrast agent (p < 0.001), angulation of the phantom to B0 with the largest artifact at 90° (p < 0.001), and encoding direction with a larger diameter in phase encoding direction (PED,p < 0.001). Mean artifact diameters at 90° angulation to B0 in PED were 18.5 ± 5.4 mm in 0.5 mmol/ml Ferucarbotran, 8.7 ± 2.5 mm in 1 mmol/ml Gadobutrol, and 11.6 ± 4.6 mm in 5 mmol/ml MnCl2.Conclusions: Fluid‐based contrast agents might be applied to interventional devices and thus temporarily augment the artifact ensuring both visibility and safe navigation.

28 April 2026 in Blood Advances
Verified
Journal Article
Open access
PDF file
Günalp UzunGünalp Uzun
Günalp Uzun
SRSergio Origel Romero
Sergio Origel Romero
JZJan Zlamal
Jan Zlamal
JJJohann Jacoby
Johann Jacoby
OBOliver Borst
Oliver Borst
KAKarina Althaus
Karina Althaus
Günalp Uzun, Sergio Origel Romero, Jan Zlamal, Johann Jacoby, Oliver Borst, Peter Rosenberger, Sven Poli, Stefanie Hammer, Tamam Bakchoul, Karina Althaus;