Saba Shamim

Dr. Saba Shamim

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2023 in Engineering Failure Analysis
Verified
Journal Article
Closed access
SSSaba Shamim
Saba Shamim
SAShakeel Ahmad
Shakeel Ahmad
RKRehan A. Khan
Rehan A. Khan

15 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
OZOmar Hamid Al zubaidy
Omar Hamid Al zubaidy
AIAmer Ibrahim
Amer Ibrahim
SASuhad Mohammed Abd
Suhad Mohammed Abd
Hadee Mohammed NajmHadee Mohammed Najm
Hadee Mohammed Najm
SSSaba Shamim
Saba Shamim
MSMohanad Sabri
Mohanad Sabri
Textile reinforced concrete (TRC) has gained attention from the construction industry due to several characteristics such as its lightweight, high tensile strength, design flexibility, corrosion resistance and remarkably long service life. Some structural applications that utilize TRC components include precast panels, structural repairs, waterproofing elements and façades. TRC is produced by incorporating textile fabrics into thin cementitious concrete panels. However, in order to use this strengthening method in construction practice, a design model is required. Investigating the combined effect of conventional steel and textile reinforcement on the ductility behavior of composite TRC/RC one-way slab is vitally important. Therefore, the current study describes the proper methods of calculating the ductility of the composite concrete reinforced by a direct combination of conventional steel and textile reinforcement. Four methods are presented to calculate the ductility of the three considered one-way slab specimens. The three slabs having dimensions 1500 mm × 500 mm × 50 mm were reinforced by steel bars (SRC), by steel with one layer of carbon fabric (SRC + 1T), and by steel with two layers of carbon fabric (SRC + 2T). The three slab specimens were cast by the hand lay-up method, removed from the molds, cured, and then tested in flexure after 28 days using the four-point bending method. The obtained results and calculations revealed the non-reasonability of using the conventional method based on yielding of steel reinforcement as the only criterion in the ductility determination. The results also confirmed the suitability of using the energy-based method over other discussed methods in the calculation of the ductility for the hybrid reinforced members.

7 July 2023 in Innovative Infrastructure Solutions
Verified
Journal Article
Closed access
PDF file
SAShakeel Ahmad
Shakeel Ahmad
RKRehan A. Khan
Rehan A. Khan
SSSaba Shamim
Saba Shamim
UCUmesh Chandra
Umesh Chandra

15 July 2022
Verified
Book Chapter
Closed access
PDF file
SSSaba Shamim
Saba Shamim
SAShakeel Ahmad
Shakeel Ahmad
RKRehan A. Khan
Rehan A. Khan

31 August 2023 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
HHHumam A. Abdul Hussein
Humam A. Abdul Hussein
AIAmer M. Ibrahim
Amer M. Ibrahim
MIMurtada A. Ismael
Murtada A. Ismael
SSSaba Shamim
Saba Shamim
HNHadee Mohammed Najm
Hadee Mohammed Najm