Ziwen Zhao

Dr. Ziwen Zhao

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2021 in Water
Verified
Journal Article
Open access
PDF file
Beibei XuBeibei Xu
Beibei Xu
LLLiuwei Lei
Liuwei Lei
ZZZiwen Zhao
Ziwen Zhao
Wei JiangWei Jiang
Wei Jiang
SXShu Xiao
Shu Xiao
Diyi ChenDiyi Chen
Diyi Chen
The penetration of multiple integrated renewable energies to the power grid are relevant for decision making in energy policy, environment and business. Such an electricity penetration is affected by the intermittent and volatile characteristics of integrated energies, mostly significantly related to the safe and stable electricity production and supply in real world. Here, this paper focuses on the low frequency oscillation analysis of the hydropower generation response to the wind and solar variability. To enable this analysis, a hybrid model of hydropower system integrating with the wind and solar power system is presented. The Nyquist and root-locus stability methods are used to investigate the sensitivity performance of the hydropower governor to the fluctuation of the integrated renewable energies. Additionally, to quantify the risk of the hybrid system, the low frequency oscillation response of hydropower system to wind/solar/hydropower quota and transmission line distance ratio is extensively investigated in this study. The results show that under the case of the wind, solar and hydropower ratio is 40:1:150, the optimal values for maximally reducing hydropower low frequency oscillation are finally determined as kp = 0.8, ki = 0.25 and kd = 0.5. Regarding a certain wind/solar/hydropower quota, it is a promising strategy to increase the solar-load transmission line in order to achieve the safe and stable operation of the hybrid system and a relatively excellent dynamic regulation capacity of the hydropower governor. The model, methods and results implemented in this study are exploited to markedly improve new knowledge applications, policy management, low carbon emissions and investment competitiveness of future energy systems.

18 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
YLYongjia Li
Yongjia Li
MZMeng Zhang
Meng Zhang
MLMing Li
Ming Li
LLLiuwei Lei
Liuwei Lei
HHHuaming Hu
Huaming Hu
Beibei XuBeibei Xu
Beibei Xu
Hydropower’s ability to start up and shut down quickly, combined with its flexible regulation characteristics, effectively alleviates frequency fluctuations caused by new energy sources, ensuring the safe and stable operation of the power system. However, during peak-frequency regulation tasks, the transition processes associated with the startup, shutdown, and load changes introduce frequent shocks to subsystems such as the hydro-turbine, governor, and diversion systems. These shocks pose significant challenges to the safe and stable operation of hydropower plants. Therefore, this study constructs a coupled hydraulic–mechanical–electrical model that incorporates the diversion system, hydro-turbine, governor, generator, and load, based on operational data from a real-world hydropower plant in China. The load increase transition process is selected for parameter sensitivity analysis to evaluate the influence of various structural, operational, and control parameters on unit stability and to identify key parameters affecting stability. The results indicate that the initial load exhibits the highest sensitivity to inversion power peak and rotational speed overshoot, with sensitivity values of 0.14 and 0.0038, respectively. The characteristic water head shows the greatest sensitivity to the inversion power peak time and rotational speed peak time, with values of 0.31 and 0.43, respectively. Additionally, the integration gain significantly influences the rotational speed rise time, with a sensitivity value of 0.30. These findings provide a theoretical basis for optimizing the parameter selection in hydropower plants.

27 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
MZMeng Zhang
Meng Zhang
JFJinhai Feng
Jinhai Feng
ZZZiwen Zhao
Ziwen Zhao
WZWei Zhang
Wei Zhang
JZJunzhi Zhang
Junzhi Zhang
Beibei XuBeibei Xu
Beibei Xu
This paper proposes a novel 1D-3D approach for the stability characteristics of the hydropower generation system (HGS) in transition processes. First, a 1D-3D coupling model was established for the HGS in the load-reduction process. Second, a sensitivity analysis of the HGS’s parameters to the rotation speed and discharge was conducted. Third, the pressure pulsation characteristics of the HGS with three typical guide vane openings were analyzed during the load-reduction process. The results show that with the closure of the guide vane, the discharge gradually decreases and it is sensitive to the change in hydraulic parameters. The rotation speed fluctuates at the early stage of the transition process and is easily affected by mechanical parameters. In addition, the pressure pulsation inside the Francis turbine is more intense under small openings than large openings, and the primary frequency of pressure pulsation under three opening degrees is the blade frequency. The 1D-3D coupling model successfully integrates the advantages of traditional methods and provides a reference for predicting system stability and exploring the stability mechanism.

1 December 2025 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
YYYuhang Yang
Yuhang Yang
HSHansong Si
Hansong Si
ZZZiwen Zhao
Ziwen Zhao
DCDiyi Chen
Diyi Chen
PZPengchong Zhao
Pengchong Zhao
NXNing Xu
Ning Xu
In hydro-turbine generator units (HTGU), accurate identification of shaft system parameters plays a crucial role in accurately predicting the dynamic response of the shaft system as well as realizing predictive maintenance. However, noise disturbances pose a significant challenge to the reliable estimation of shaft system parameters. We propose an Adaptive Staged Training Physics Informed Neural Network (AST-PINN) method for shaft system parameter identification. Specifically, the damping and stiffness coefficients of the shaft system are selected as unknown parameters that are updated together with the parameters of the neural network. Then the weights of different loss terms are adaptively assigned by maximum likelihood estimation of Gaussian distribution. In addition, a two-stage training strategy is proposed, aiming to simultaneously fit the dynamic response with the unknown parameters in the shaft system equations. The results show that the proposed method is effective in identifying the unknown parameters of the shaft system, and the relative errors of all the unknown parameters are less than 5%. The influence on the accuracy of parameter identification in the case of noise interference in the measured data is also analyzed.

12 October 2026 in Renewable Energy
Verified
Journal Article
Closed access
ZBZekai Bai
Zekai Bai
ZZZiwen Zhao
Ziwen Zhao
HSHaoyan Song
Haoyan Song
YYYvhang Yang
Yvhang Yang
RXRenwei Xue
Renwei Xue
Diyi ChenDiyi Chen
Diyi Chen

12 June 2025 in Water
Verified
Journal Article
Open access
PDF file
ZBZekai Bai
Zekai Bai
JLJianling Li
Jianling Li
YMYunzhe Ma
Yunzhe Ma
XSXianan Sun
Xianan Sun
HSHansong Si
Hansong Si
Diyi ChenDiyi Chen
Diyi Chen
In this study, a bending–torsional coupling vibration model of the hydro-turbine generator unit (HTGU) incorporating the gyroscopic effect is developed. Using numerical simulation grounded in the actual installation and operational parameters of a hydropower station in China, the vibration characteristics of the HTGU are analyzed under conditions with and without hydraulic excitation, as well as with and without consideration of the gyroscopic effect. Through numerical simulation, it was found that the difference in the x-direction vibration amplitude of the generator rotor between model 1 and model 2 during the start-up phase was less than 5%, indicating that the gyroscopic effect had no influence on the bending–torsional vibration of the HTGU during the start-up phase. However, after a certain period of time, the gyroscopic effect on the bending–torsional vibration of the unit gradually becomes apparent. The vibration amplitude in the x-direction of model 1 is 28% higher than that of model 2, and the amplitude difference in the y-direction reaches 19%. Furthermore, it was found that due to the effects of hydraulic excitation and gyroscopic force, the vibration characteristics of the generator rotor and the turbine runner in the x- and y-directions were different. Under hydraulic excitation, the amplitude of the y-direction vibration of the turbine runner in model 1 was 31% lower than that in model 2. The findings of this study provide a theoretical basis for the modeling and installation of hydro-turbine generator units (HTGUs).