The clocking position of the vaned diffuser, the circumferential position of the vaned diffuser relative to the volute, has a certain effect on the performance of the centrifugal pump. Therefore, this paper studies the guide vane centrifugal pump from the aspects of pressure pulsation, hydraulic performance, and energy loss. The maximum difference in efficiency is 3.4% under the design flow rate, and the maximum difference in the head coefficient is 4.7%. The hydraulic performance and pressure pulsation present different trends with the increase of the vaned diffuser clock angle. When the hydraulic performance and pressure pulsation are relatively good, the circumferential distance between the tongue and the upstream vaned diffuser blade is 3/4 of the diffuser flow path. In addition, the recommended vaned diffuser installation location may also be suitable for centrifugal pumps of similar construction. The energy loss was visualized using the theory of entropy production. The distributions of energy loss and flow field indicate that the energy loss of impeller and vaned diffuser changes little. The change of the vortex in the tongue and outlet area will cause a significant change in the energy loss of the volute, which is the main reason that the hydraulic performance of the centrifugal pump is affected by the clocking position of the vaned diffuser.
The penetration of multiple integrated renewable energies to the power grid are relevant for decision making in energy policy, environment and business. Such an electricity penetration is affected by the intermittent and volatile characteristics of integrated energies, mostly significantly related to the safe and stable electricity production and supply in real world. Here, this paper focuses on the low frequency oscillation analysis of the hydropower generation response to the wind and solar variability. To enable this analysis, a hybrid model of hydropower system integrating with the wind and solar power system is presented. The Nyquist and root-locus stability methods are used to investigate the sensitivity performance of the hydropower governor to the fluctuation of the integrated renewable energies. Additionally, to quantify the risk of the hybrid system, the low frequency oscillation response of hydropower system to wind/solar/hydropower quota and transmission line distance ratio is extensively investigated in this study. The results show that under the case of the wind, solar and hydropower ratio is 40:1:150, the optimal values for maximally reducing hydropower low frequency oscillation are finally determined as kp = 0.8, ki = 0.25 and kd = 0.5. Regarding a certain wind/solar/hydropower quota, it is a promising strategy to increase the solar-load transmission line in order to achieve the safe and stable operation of the hybrid system and a relatively excellent dynamic regulation capacity of the hydropower governor. The model, methods and results implemented in this study are exploited to markedly improve new knowledge applications, policy management, low carbon emissions and investment competitiveness of future energy systems.
To better reveal the mechanism of the rotor‐stator interference between the impeller and the guide vane and the evolution process of the stall vortex under the part‐load conditions, numerical simulation is carried out based on the DDES turbulence model, which can better capture vortex structure. And the pressure pulsation and the radial velocity distribution of the centrifugal pump are studied. The vortex structure and pressure fluctuation of pump internal flow field under part‐load condition of Q = 0.4 Qdes are mainly analyzed. The analysis results show that the stall vortex is formed at the inlet of the impeller and evolves to the outlet of the impeller, the front cover to the rear cover according to the fluid flow direction, and then disappears. Besides, under the part‐load condition, the vorticity of the impeller outlet is always obviously less than that of the impeller inlet as the flow rate increases. Due to the asymmetric action of the volute, the radial velocity distribution law of flow channel C1 is different from other flow channels at different blade heights. By analyzing the radial velocity, the phenomenon that the jet‐wake flow impacts the guide vane with the rotation of the impeller is the main reason for the rotor‐stator interference. And large radial velocity gradients appear at the front and rear cover plates, which will cause high energy loss and reduce pump efficiency. Besides, the conclusion can be drawn that the region with the strongest rotor‐stator interference is the inlet region of the guide vane suction surface. It also occurs near the volute tongue but is lower due to the effect of the guide vane. This research may serve as a reference for the safe operation of centrifugal pumps under part‐load conditions.
18 January 2023 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
In order to study temporal and spatial variation of energy loss and reveal influence rule of clocking effect on energy loss and flow field in centrifugal pump with vaned diffuser, numerical simulations were carried out. Numerical simulations were validated by experiments. Local equilibrium of turbulence generation and dissipation was verified to state feasibility of energy loss methods. Hydraulic loss in each component was assessed, which shows that variation of hydraulic loss in volute is more significant due to clocking effect than that in other components. Vortical structure in volute varies greater under different guide vane positions than it in other components. The results show that positive and negative flow angle appears interlaced in tongue region with high velocity gradient, especially when diffuser is mounted at θd1. Since a clearance presents between tongue and vane trailing edge at θd1, a small vortex forms. Which promotes the blocking effect of the large-scale vortex at volute outlet pipe. Therefore, high velocity gradient appears at small vortex region and volute outlet pipe region. The shear strain rate at the tongue and volute outlet pipe is more significant than that at other diffuser mounted positions. Energy loss at these regions increases. This situation can be improved by a more suitable diffuser mounted position θd4, where the clearance and small vortex vanishes, the shear strain rate, velocity gradient, and energy loss decrease.
25 May 2023 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
In a micro centrifugal pump with tip clearance working at high speed, the pressure fluctuation and complex vortex structures related to the tip leakage flow are conducted. The external characteristics calculated by the numerical simulation and experiment method agree well, and the maximum deviation of the simulated pump head and efficiency compared with the experimental data is less than 5%. The vortex structures induced by the tip clearance flow, which is less influenced by the flow conditions, can be divided into four categories, namely backflow vortex, passage vortex, primary tip clearance flow (PTLV), and separation TLV (STLV). The evolution of these vortex structures is described by the relative vorticity transport equation, using the relative vortex stretching, Coriolis force, and viscous diffusion. The PTLV starts from the corner of blade tip gap near the leading edge (LE), and breaks away into the STLV in the region of 0.7 R* to 0.8 R* owing to the pushing effect of the secondary tip leakage flow. To analyze the leakage flow quantitatively, the relative velocity in the gap region is decomposed. The results show that the local maximal and minimal values of the normal component correspond to the start position of the PTLV and the separation region of the STLV, respectively. Besides, the passage vortex has the greatest contribution to the pressure pulsation of the passage from main blade to main blade (MB). But the dominant frequency of the pressure alterations has little to do with the vortex, and mainly depends on the rotor-stator interaction (RSI) between the impeller and volute tongue. The results could be referred to improve the efficiency and operational stability of the high-speed centrifugal pumps.