Olivier Couture

Olivier Couture

Auto-generated profile, based on publicly available information

Olivier Couture

Sorbonne Université, UMR 7371 CNRS, Inserm U1146, Laboratoire d’Imagerie Biomédicale, Paris, France

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2015 in Nature
Verified
Journal Article
Closed access
CEClaudia Errico
Claudia Errico
JPJuliette Pierre
Juliette Pierre
SPSophie Pezet
Sophie Pezet
YDYann Desailly
Yann Desailly
ZLZsolt Lenkei
Zsolt Lenkei
MTMickael Tanter
Mickael Tanter

21 January 2020 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
KCKirsten Christensen-Jeffries
Kirsten Christensen-Jeffries
OCOlivier Couture
Olivier Couture
PDPaul A. Dayton
Paul A. Dayton
YEYonina C. Eldar
Yonina C. Eldar
KHKullervo Hynynen
Kullervo Hynynen
RSRuud J.G. van Sloun
Ruud J.G. van Sloun

26 June 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
OCOlivier Couture
Olivier Couture
VHVincent Hingot
Vincent Hingot
BHBaptiste Heiles
Baptiste Heiles
PMPauline Muleki-Seya
Pauline Muleki-Seya
MTMickael Tanter
Mickael Tanter
Because it drives the compromise between resolution and penetration, the diffraction limit has long represented an unreachable summit to conquer in ultrasound imaging. Within a few years after the introduction of optical localization microscopy, we proposed its acoustic alter ego that exploits the micrometric localization of microbubble contrast agents to reconstruct the finest vessels in the body in-depth. Various groups now working on the subject are optimizing the localization precision, microbubble separation, acquisition time, tracking, and velocimetry to improve the capacity of ultrasound localization microscopy (ULM) to detect and distinguish vessels much smaller than the wavelength. It has since been used in vivo in the brain, the kidney, and tumors. In the clinic, ULM is bound to improve drastically our vision of the microvasculature, which could revolutionize the diagnosis of cancer, arteriosclerosis, stroke, and diabetes.

21 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VHVincent Hingot
Vincent Hingot
CEClaudia Errico
Claudia Errico
BHBaptiste Heiles
Baptiste Heiles
LRLine Rahal
Line Rahal
MTMickael Tanter
Mickael Tanter
OCOlivier Couture
Olivier Couture
Medical ultrasound is a widely used diagnostic imaging technique for tissues and blood vessels. However, its spatial resolution is limited to a sub-millimeter scale. Ultrasound Localization Microscopy was recently introduced to overcome this limit and relies on subwavelength localization and tracking of microbubbles injected in the blood circulation. Yet, as microbubbles follow blood flow, long acquisition time are required to detect them in the smallest vessels, leading to long reconstruction of the microvasculature. The objective of this work is to understand how blood flow limits acquisition time. We studied the reconstruction of a coronal slice of a rat’s brain during a continuous microbubble injection close to clinical concentrations. After acquiring 192000 frames over 4 minutes, we find that the biggest vessels can be reconstructed in seconds but that it would take tens of minutes to map the entire capillary network. Moreover, the appropriate characterization of flow profiles based on microbubble velocity within vessels is bound by even more stringent temporal limitations. As we use simple blood flow models to characterize its impact on reconstruction time, we foresee that these results and methods can be adapted to determine adequate microbubble injections and acquisition times in clinical and preclinical practice.

21 October 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YDYann Desailly
Yann Desailly
OCOlivier Couture
Olivier Couture
MFMathias Fink
Mathias Fink
MTMickael Tanter
Mickael Tanter
Scanned at very high ultrasound frame rates, injectable microbubbles can be activated sequentially as isolated punctual sources of acoustic echoes. These signals can thus be localized far beyond the diffraction limit. The resolution improvement granted by Sono-Activated Ultrasound Localization Microscopy (SAULM) was demonstrated within microfluidic channels 20 times smaller than the imaging wavelength (λ = 870 μm). The width of the channels mapped with SAULM was 13 times smaller than as they appeared under conventional ultrasound imaging. Two channels separated by λ/4.5 could be distinguished. Implementing SAULM in-vivo could lead to a complete reconstruction of the vascular tree down to the smallest capillaries at several centimeter depth.

27 December 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
OCOlivier Couture
Olivier Couture
MFMathias Fink
Mathias Fink
MTMickael Tanter
Mickael Tanter
Background: Monitoring the accumulation of microbubbles within tissue vasculature with ultrasound allows both molecular and perfusion imaging. Unfortunately, conventional imaging with focused pulses can destroy a large fraction of the microbubbles it is trying to follow. Using coherent synthetic summation, ultrafast plane wave imaging could attain similar image quality, while reducing the peak acoustic pressure and bubble disruption. Method: In these experiments, microbubbles were flowed in a wall-less vessel phantom. Images were obtained on a programmable clinical scanner with a set of line-per-line focused pulses for conventional contrast imaging and with compounded plane wave transmission adapted for nonlinear imaging. Imaging was performed between 14 and 650 kPa peak negative pressure at 7.5 MHz. The disruption of the microbubbles was evaluated by comparing the microbubble intensity before and after acquisition of a set of 100 images at various pressures. Results: The acoustic intensity required to disrupt 50% of the microbubbles was 24 times higher with plane-wave imaging compared with conventional focused pulses. Although both imaging approaches yield similar resolution, at the same disruption level, plane-wave imaging showed better contrast. In particular, at similar disruption ratio (50% after 100 images), contrast-pulse sequencing (CPS) performed with plane waves displayed an improvement of 11 dB compared with conventional nonlinear imaging. Conclusion: In each resolution cell of the image, plane-wave imaging spread the spatial peak acoustic intensity over more pulses, reducing the peak pressure and, hence, preserving the microbubbles. This method could contribute to molecular imaging by allowing the continuous monitoring of the accumulation of microbubbles with improved contrast.