Knowledge about moisture content in oil impregnated paper insulation is essential when estimating remaining lifetime of power transformers. Direct evaluation of moisture content is rarely possible due to inaccessibility of the internal insulation system in transformers. Therefore, various indirect estimation techniques are utilized. Frequency domain spectroscopy (FDS) measurements of transformer insulation belong to this group. To perform high quality interpretation of results of FDS measurements a good knowledge on dielectric responses in oil impregnated pressboard and paper is required, especially as it refers to their variation with water content and temperature. The aim of this paper is to provide an open access to the frequency domain spectra of oil impregnated paper and pressboard samples, which can then be used in modeling of the results of diagnostic measurements in power transformers.
27 March 2006 in IEEE Transactions on Power Delivery
Some new methods, based on characterization of the dielectric response of transformer insulation in time and frequency domains, have been pointed out by CIGRE as suitable to assess moisture content in pressboard and paper. Measuring devices available today on the market are quite robust in field conditions; however there is a risk that undesired internal and external factors might influence the measurements. These influences can lead to mistaken interpretation of insulation wetness. Operators should therefore be aware of the risks appearing at different measuring conditions and of the precautions that can be taken to minimize their effects. This work presents a systematic investigation on the influence of some factors on the results of dielectric response measurements in field conditions. The errors that can be committed during the measurements if certain precautions are not taken, with different equipment connected in parallel, are evaluated. The influence of rain and electromagnetic disturbances are also analyzed proposing solutions to attenuate their effects. Finally, a discussion on the influence of temperature distribution follows. The work is concentrated on frequency response measurements, although some results from the use of polarization and depolarization current technique are also discussed.
24 May 2013 in IEEE Transactions on Dielectrics and Electrical Insulation
The article presents the results of extensive investigations aimed at determining the moisture content in a large population of power transformers (161 units). The project was carried out during the period of 2003-2011 in Poland, Germany, and Sweden. All results were obtained by means of the Frequency Response Spectroscopy (FDS) method. Among the transformers tested were grid transformers, generator step-up (GSU) transformers, and distribution transformers. According to the classification rules established by IEEE, 30% among the investigated transformers could be classified as “wet” (2-4% moisture content). The observed moisture variation with age was found to depend on transformer design and operating conditions. It is suggested that, based on the presented statistical results and knowledge concerning transformer type and age, one may discriminate between probably dry transformers and transformers that require actual moisture analysis and therefore prioritize further condition assessment.
The article presents a novel on-line partial discharge (PD) monitoring system for power transformers, whose functioning is based on the simultaneous use of three unconventional methods of PD detection: high-frequency (HF), ultra-high frequency (UHF), and acoustic emission (AE). It is the first monitoring system equipped in an active dielectric window (ADW), which is a combined ultrasonic and electromagnetic PD sensor. The article discusses in detail the process of designing and building individual modules of hardware and software layers of the system, wherein the most attention was paid to the PD sensors, i.e., meandered planar inverted-F antenna (MPIFA), high-frequency current transformer (HFCT), and active dielectric window with ultrasonic transducer, which were optimized for detection of PDs occurring in oil-paper insulation. The prototype of the hybrid monitoring system was first checked on a 330 MVA large power transformer during the induced voltage test with partial discharge measurement (IVPD). Next, it was installed on a 31.5 MVA substation power transformer and integrated according to the standard IEC 61850 with SCADA (Supervisory Control and Data Acquisition) system registering voltage, active power, and oil temperature of the monitored unit. The obtained results showed high sensitivity of the manufactured PD sensors as well as the advantages of the simultaneous use of three techniques of PD detection and the possibility of discharge parameter correlation with other power transformer parameters.
Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats to proper operation of the transformer, e.g., ignition of partial discharges (PDs). Due to the varying temperature of the insulation system during the unit’s normal operation, a dynamic change (migration of water) takes place, precipitating the oil-paper system from a state of hydrodynamic equilibrium. This causes the PDs to be variable in time, and they may intensify or extinguish. Studies on model objects have been conducted to determine the conditions (temperature, humidity, time) that will have an impact on the ignition and intensity of the observed phenomenon of PDs. The conclusions of this study will have a practical application in the evaluation of measurements conducted in the field, especially in relation to the registration of an online PD monitoring system.
1 December 2012 in IEEE Transactions on Dielectrics and Electrical Insulation
This paper elucidates the question whether bubble effect can possibly take place in the insulation of OIP (Oil Impregnated Paper) type of bushings. The investigations were performed on a bushing insulation model and indicated to a possibility that the effect may occur. Presence of metallic screens in the insulation does not limit the development of gas bubbling; they only force the motion of water vapor bubbles along the model axis. The temperature dependence of bubble initiation on the water content in paper part of the bushing insulation is similar to the presented earlier in literature characteristics for bubbling in main insulation of power transformers. The possibility of bubble effect occurrence may explain the relatively frequent cases of transformer bushing failures.