Hubert Morańda

Prof. Hubert Morańda

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2013 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JGJaroslaw Gielniak
Jaroslaw Gielniak
AGA. Graczkowski
A. Graczkowski
HMHubert Morańda
Hubert Morańda
PPP. Przybylek
P. Przybylek
KWKrzysztof Walczak
Krzysztof Walczak
SGS. M. Gubanski
S. M. Gubanski
The article presents the results of extensive investigations aimed at determining the moisture content in a large population of power transformers (161 units). The project was carried out during the period of 2003-2011 in Poland, Germany, and Sweden. All results were obtained by means of the Frequency Response Spectroscopy (FDS) method. Among the transformers tested were grid transformers, generator step-up (GSU) transformers, and distribution transformers. According to the classification rules established by IEEE, 30% among the investigated transformers could be classified as “wet” (2-4% moisture content). The observed moisture variation with age was found to depend on transformer design and operating conditions. It is suggested that, based on the presented statistical results and knowledge concerning transformer type and age, one may discriminate between probably dry transformers and transformers that require actual moisture analysis and therefore prioritize further condition assessment.

1 December 2012 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Wojciech SikorskiWojciech Sikorski
Wojciech Sikorski
KSKrzysztof Siodla
Krzysztof Siodla
HMHubert Morańda
Hubert Morańda
WZWaldemar Ziomek
Waldemar Ziomek
In the paper a new partial discharge (PD) location technique based on acoustic emission and conventional partial discharge detection method is presented. Synergetic combination of two methods allows obtaining a high accuracy of the insulation fault location and reducing the time of measurement procedure. Several cases of practical application of the new technique for PD location in the power transformers tested in an HV laboratory and in a substation are discussed.

1 December 2012 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
PPP. Przybylek
P. Przybylek
HMHubert Morańda
Hubert Morańda
KWKrzysztof Walczak
Krzysztof Walczak
HMH. Moscicka-Grzesiak
H. Moscicka-Grzesiak
This paper elucidates the question whether bubble effect can possibly take place in the insulation of OIP (Oil Impregnated Paper) type of bushings. The investigations were performed on a bushing insulation model and indicated to a possibility that the effect may occur. Presence of metallic screens in the insulation does not limit the development of gas bubbling; they only force the motion of water vapor bubbles along the model axis. The temperature dependence of bubble initiation on the water content in paper part of the bushing insulation is similar to the presented earlier in literature characteristics for bubbling in main insulation of power transformers. The possibility of bubble effect occurrence may explain the relatively frequent cases of transformer bushing failures.

3 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
HMHubert Morańda
Hubert Morańda
HMHanna Moscicka-Grzesiak
Hanna Moscicka-Grzesiak
PPPiotr Przybylek
Piotr Przybylek
KWKrzysztof Walczak
Krzysztof Walczak
RSRadoslaw Szewczyk
Radoslaw Szewczyk
The article presents the results of comparative investigations of partial discharges in two insulation systems; aramid-enhanced cellulose paper-mineral oil, and pure cellulose paper-mineral oil. Partial discharges were investigated in a diagonal electric field with vertical and horizontal components. This field is treated as the most dangerous for insulation. The research was carried out on Nomex® 910 paper and cellulose paper samples, each paper being 0.25 mm thick. Samples of the two materials were tested at four levels of moisture. The inception voltage of partial discharges of all samples tested decreased as their moisture content increases. It was also proved that Nomex® 910 has a significantly higher partial discharge inception voltage than the cellulose paper, although this difference decreased with increasing moisture content.

13 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
PPPiotr Przybylek
Piotr Przybylek
HMHubert Morańda
Hubert Morańda
HMHanna Moscicka-Grzesiak
Hanna Moscicka-Grzesiak
DSDominika Szczesniak
Dominika Szczesniak
A high level of insulation moisture in a transformer increases the breakdown probability and forces a reduction of its load. Therefore, there is a need to dry the transformer insulation. For technical reasons, there are some restrictions on the use of common drying methods for cellulose insulation available on the market. The aim of the research was to check the possibility of using synthetic ester for effective drying of cellulose materials of various thickness and an evaluation of the drying dynamics. The replacement of mineral oil with a synthetic ester caused a reduction of moisture in paper and thin pressboard by one percentage point. It was possible in the case of drying these materials for seven days at a temperature of 70 °C. The effects of drying were much smaller in the case of thicker cellulose samples. This paper also shows the complex problem of simultaneously drying materials of different thicknesses. Drying thin paper and thick pressboard at the same time significantly slows down the drying process of the pressboard. Presented results will be used to develop a procedure for drying the transformer insulation system using a synthetic ester.

4 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
PPPiotr Przybylek
Piotr Przybylek
HMHubert Morańda
Hubert Morańda
HMHanna Moscicka-Grzesiak
Hanna Moscicka-Grzesiak
MCMateusz Cybulski
Mateusz Cybulski
This paper presents the results of laboratory tests of cellulose insulation drying with the use of synthetic ester. The effectiveness of the drying process was investigated depending on the initial moisture of cellulose samples (2%, 3%, and 4%), ester temperature (55, 70, and 85 °C), initial moisture of the ester (70, 140, and 220 ppm), drying time (48, 96, and 168 h), and the weight ratio of cellulosic materials to ester (0.067 and 0.033). A large influence of temperature and time of drying on the efficiency of the drying process was found. This is important information due to the application of the results in the transformers drying procedure. The heating and drying ester unit should provide the highest possible temperature. For the assumed experiment conditions the initial moisture of the ester had little effect on the drying efficiency. An ester with a moisture content below 140 ppm can still be considered as meeting the requirements for drying cellulose with significant moisture. The weight ratio of cellulose products to ester has no major effect on drying efficiency during cellulose drying by circulating dry ester.