Xuejun Qian

Dr. Xuejun Qian

Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
XQXuejun Qian
Xuejun Qian
JPJing Pei
Jing Pei
HZHui Zheng
Hui Zheng
XXXinxin Xie
Xinxin Xie
LYLin Yan
Lin Yan
KSK. Kirk Shung
K. Kirk Shung

1 May 2023 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
HHHongjie Hu
Hongjie Hu
YMYuxiang Ma
Yuxiang Ma
XGXiaoxiang Gao
Xiaoxiang Gao
DSDawei Song
Dawei Song
MLMohan Li
Mohan Li
Sheng XuSheng Xu
Sheng Xu

4 December 2024 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
XQXuejun Qian
Xuejun Qian
JPJing Pei
Jing Pei
CHChunguang Han
Chunguang Han
ZLZhiying Liang
Zhiying Liang
GZGaosong Zhang
Gaosong Zhang
DSDinggang Shen
Dinggang Shen

19 November 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Ruimin ChenRuimin Chen
Ruimin Chen
K. Kirk ShungK. Kirk Shung
K. Kirk Shung
TMTeng Ma
Teng Ma
Qifa ZhouQifa Zhou
Qifa Zhou
LJLaiming Jiang
Laiming Jiang
JZJianguo Zhu
Jianguo Zhu
High-frequency ultrasonic imaging with improved spatial resolution has gained increasing attention in the field of biomedical imaging. Sensitivity of transducers plays a pivotal role in determining ultrasonic image quality. Conventional ultrasonic transducers are mostly made from lead-based piezoelectric materials that may be harmful to the human body and the environment. In this study, a new (K,Na)NbO $_{3}$ -KTiNbO $_5$ -BaZrO $_{3}$ -Fe $_{2}$ O $_{3}$ -MgO (KNN-NTK-FM) lead-free piezoelectric ceramic was utilized in developing eco-friendly transducers for high-frequency biomedical ultrasonic imaging applications. A needle transducer with a small active aperture size of 0.45 × 0.55 mm $^2$ was designed and evaluated. The fabricated transducer exhibits great performance with a high center frequency (52.6 MHz), a good electromechanical coupling ( $k$ $_{eff}$ ~ 0.45), a large bandwidth (64.4% at -6 dB), and a very low two-way insertion loss (10.1 dB). Such high sensitivity is superior to those transducers based on other lead-free piezoelectric materials and can even be comparable to the lead-based ones. Imaging performance of the KNN-NTK-FM needle transducer was analyzed by imaging a wire phantom and an agar tissue-mimicking phantom. Imaging capabilities of the transducer were further demonstrated by ex vivo imaging studies on a porcine eyeball and a rabbit aorta. The results suggest that the KNN-NTK-FM piezoceramic has many attractive properties over other lead-free piezoelectric materials in developing eco-friendly highly sensitive transducers for high-frequency biomedical ultrasonic imaging applications.

28 March 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
CSCho-Chiang Shih
Cho-Chiang Shih
XQXuejun Qian
Xuejun Qian
TMTeng Ma
Teng Ma
Zhaolong HanZhaolong Han
Zhaolong Han
Chih-Chung HuangChih-Chung Huang
Chih-Chung Huang
K. Kirk ShungK. Kirk Shung
K. Kirk Shung
Characterizing the viscoelastic properties of thin-layer tissues with micro-level thickness has long remained challenging. Recently, several micro-elastography techniques have been developed to improve the spatial resolution. However, most of these techniques have not considered the medium boundary conditions when evaluating the viscoelastic properties of thin-layer tissues such as arteries and corneas; this might lead to estimation bias or errors. This paper aims to integrate the Lamb wave model with our previously developed ultrasonic micro-elastography imaging system for obtaining accurate viscoelastic properties in thin-layer tissues. A 4.5-MHz ring transducer was used to generate an acoustic radiation force for inducing tissue displacements to produce guided wave, and the wave propagation was detected using a confocally aligned 40-MHz needle transducer. The phase velocity and attenuation were obtained from k-space by both the impulse and the harmonic methods. The measured phase velocity was fit using the Lamb wave model with the Kelvin-Voigt model. Phantom experiments were conducted using 7% and 12% gelatin and 1.5% agar phantoms with different thicknesses (2, 3, and 4 mm). Biological experiments were performed on porcine cornea and rabbit carotid artery ex vivo . Thin-layer phantoms with different thicknesses were confirmed to have the same elasticity; this was consistent with the estimates of bulk phantoms from mechanical tests and the shear wave rheological model. The trend of the measured attenuations was also confirmed with the viscosity results obtained using the Lamb wave model. Through the impulse and harmonic methods, the shear viscoelasticity values were estimated to be 8.2 kPa for 0.9 Pa·s and 9.6 kPa for 0.8 Pa·s in the cornea and 27.9 kPa for 0.1 Pa·s and 26.5 kPa for 0.1 Pa·s in the artery.

21 April 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
XQXuejun Qian
Xuejun Qian
CHChengwu Huang
Chengwu Huang
RLRunze Li
Runze Li
BSBrian J. Song
Brian J. Song
HTHisham Tchelepi
Hisham Tchelepi
Qifa ZhouQifa Zhou
Qifa Zhou
Objective: The ocular vascular system plays an important role in preserving the visual function. Alterations in either anatomy or hemodynamics of the eye may have adverse effects on vision. Thus, an imaging approach that can monitor alterations of ocular blood flow of the deep eye vasculature ranging from capillary-level vessels to large supporting vessels would be advantageous for detection of early stage retinal and optic nerve diseases. Methods: We propose a super-resolution ultrasound localization microscopy (ULM) technique that can assess both the microvessel and flow velocity of the deep eye with high resolution. Ultrafast plane wave imaging was acquired using an L22-14v linear array on a high frequency Verasonics Vantage system. A robust microbubble localization and tracking technique was applied to reconstruct ULM images. The experiment was first performed on pre-designed flow phantoms in vitro and then tested on a New Zealand white rabbit eye in vivo calibrated to various intraocular pressures (IOP) – 10 mmHg, 30 mmHg and 50 mmHg. Results: We demonstrated that retinal/choroidal vessels, central retinal artery, posterior ciliary artery, and vortex vein were all visible at high resolution. In addition, reduction of vascular density and flow velocity were observed with elevated IOPs. Conclusion: These results indicate that super-resolution ULM is able to image the deep ocular tissue while maintaining high resolution that is comparable with optical coherence tomography angiography. Significance: Capability to detect subtle changes of blood flow may be clinically important in detecting and monitoring eye diseases such as glaucoma.