Transmission lines are an important part of the power system, as they are the carriers of power from one end to another. In the event of a fault, the power transferring process is disturbed and can even damage the equipment, which is attached to the generation end as well as the user end. Most of the power systems are connected to the transmission lines, so it is very important to make the transmission lines secure. For protection purposes, relays are used, but relays only trip in the event of a fault and do not tell us about the location of the fault. The power system requires a speedy protection system. For a speedy protection system, quick and fast fault analysis and classification are required. An effective approach for the analysis of the transmission line with three sources is proposed. This method is quite effective and accurate for locating the fault and classifying its types. This technique needs power measurement from both ends simultaneously for fault diagnosis. Instantaneous power and sign power values are used for fault detection and classification. A voltage profile is used to identify the fault location. For three-phase transmission lines, voltage profiles are built up at different segment points to locate the fault. The IEEE-9 bus system is simulated for this technique. MATLAB is employed for simulation purposes. The test system is simulated with different types of faults at different locations. Relay operation has not affected the accuracy of the system. This technique has an accuracy of more than 97%. This method is quite effective for the analysis of power transmission lines. It can discriminate the fault type, identify the faulty phase of the line, and locate the point of the fault. Faults are located with errors not more than 0.45%. Moreover, the time difference between the actual fault and the calculated fault obtained from the estimated location is not more than 0.004 s. Simulations are claimed to be executed in less computational time, ensuring effective and rapid protection against faults.
Device-to-device communication offers a promising technology for the 5G network that aims to enhance the data rate, reduce latency and cost, improve energy efficiency, and provide other desired features. The 5G heterogeneous network (5GHN) with a decoupled association strategy of downlink (DL) and uplink (UL) is a promising solution for the challenges faced in the 4G heterogeneous network (4GHN). The research presented in this paper evaluates the performance of the 4GHN as well as a DL-and-UL-coupled (DU-CP) access scheme in comparison with the 5GHN with a DL-and-UL-decoupled (DU-DCP) access scheme in terms of the energy efficiency and network throughput in four-tier heterogeneous networks. The energy and throughput are optimized for both scenarios, i.e., DU-CP and DU-DCP, and the results are compared. Detailed performance analyses of the DU-CP and DU-DCP access schemes were conducted with the help of comparisons of the results achieved by implementing a genetic algorithm (GA) and particle swarm optimization (PSO). Both of these algorithms are suited for the non-linear problem under investigation in which the search space is large. The simulation results have shown that the DU-DCP access scheme gives a better performance than the DU-CP scheme in a four-tier heterogeneous network in terms of network throughput and energy efficiency. The PSO achieves an energy efficiency of 12 Mbits/joule for the DU-CP and 42 Mbits/joule for the DU-DCP, whereas the GA yields an energy efficiency of 28 Mbits/joule for the DU-CP and 55 Mbits/joule for the DU-DCP. The performance of the proposed method is compared with those of three other schemes. The results show that the DU-DCP scheme using the GA outperforms the compared methods.
1 April 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Adaptation of renewable energy is inevitable. The idea of microgrid offers integration of renewable energy sources with conventional power generation sources. In this research, an operative approach was proposed for microgrids comprising of four different power generation sources. The microgrid is a way that mixes energy locally and empowers the end-users to add useful power to the network. IEEE-14 bus system-based microgrid was developed in MATLAB/Simulink to demonstrate the optimal power flow. Two cases of battery charging and discharging were also simulated to evaluate its realization. The solution of power flow analysis was obtained from the Newton–Raphson method and particle swarm optimization method. A comparison was drawn between these methods for the proposed model of the microgrid on the basis of transmission line losses and voltage profile. Transmission line losses are reduced to about 17% in the case of battery charging and 19 to 20% in the case of battery discharging when system was analyzed with the particle swarm optimization. Particle swarm optimization was found more promising for the deliverance of optimal power flow in the renewable energy sources-based microgrid.