High voltage direct current (HVDC) transmission systems are suitable for power transfer to meet the increasing demands of bulk energy and encourage interconnected power systems to incorporate renewable energy sources without any fear of loss of synchronism, reliability, and efficiency. The main challenge associated with DC grid protection is the timely diagnosis of DC faults because of its rapid built up, resulting in failures of power electronic circuitries. Therefore, the demolition of HVDC systems is evaded by identification, classification, and location of DC faults within milliseconds (ms). In this research, the support vector machine (SVM)-based protection algorithm is developed so that DC faults could be identified, classified, and located in multi-terminal high voltage direct current (MT-HVDC) systems. A four-terminal HVDC system is developed in Matlab/Simulink for the analysis of DC voltages and currents. Pole to ground and pole to pole faults are applied at different locations and times. Principal component analysis (PCA) is used to extract reduced dimensional features. These features are employed for the training and testing of SVM. It is found from simulations that DC faults are identified, classified, and located within 0.15 ms, ensuring speedy DC grid protection. The realization and practicality of the proposed machine learning algorithm are demonstrated by analyzing more straightforward computations of standard deviation and normalization.
The HVDC transmission system is winning hearts of researchers and electrical engineers because of its notable merits as compared to the HVAC transmission system in the case of long-distance bulk power transmission. The HVDC transmission system is known for its low losses, effective control ability, efficiency and reliability. However, because of the sudden build-up of fault current in the HVDC transmission system, conventional relays and circuit breakers are required to be modified. Detection of fault location is an important parameter of protection of the HVDC transmission system. In this research paper, fault location methods based on traveling waves are reviewed for the HVDC transmission system. Arrival time and natural frequency are the two parameters of measurement in traveling waves. Advantages and disadvantages of methods of traveling waves with respect to their quantities of measurements are analyzed critically. Further, a two-terminal HVDC test grid is simulated over Matlab/Simulink. Different types of AC and DC faults and at different locations are analyzed on a test grid. A traveling wave-based technique of fault estimation is developed and is evaluated for identification, classification and finding location of faults to validate its performance. Moreover, this technique is supported with analysis of fast Fourier transform to accelerate its practicality and realization.
The integration of offshore wind farms has revitalized the interest in multi–terminal high voltage direct current (M–HVdc) transmission grids. HVdc breakers’ importance has increased as M–HVdc grids are now a commercial truth. Several HVdc circuit breaker technologies have been developed, published, and appeared as prototypes for HVdc networks. This paper summarizes the HVdc breaker technologies from the last two decades, distributed mainly in literature. A comparison of various state–of–the–art HVdc breakers is presented. Further, areas are identified where further research and development are required. The goal is to provide primary challenges and prospects in the HVdc breaker field.
Transmission lines are an important part of the power system, as they are the carriers of power from one end to another. In the event of a fault, the power transferring process is disturbed and can even damage the equipment, which is attached to the generation end as well as the user end. Most of the power systems are connected to the transmission lines, so it is very important to make the transmission lines secure. For protection purposes, relays are used, but relays only trip in the event of a fault and do not tell us about the location of the fault. The power system requires a speedy protection system. For a speedy protection system, quick and fast fault analysis and classification are required. An effective approach for the analysis of the transmission line with three sources is proposed. This method is quite effective and accurate for locating the fault and classifying its types. This technique needs power measurement from both ends simultaneously for fault diagnosis. Instantaneous power and sign power values are used for fault detection and classification. A voltage profile is used to identify the fault location. For three-phase transmission lines, voltage profiles are built up at different segment points to locate the fault. The IEEE-9 bus system is simulated for this technique. MATLAB is employed for simulation purposes. The test system is simulated with different types of faults at different locations. Relay operation has not affected the accuracy of the system. This technique has an accuracy of more than 97%. This method is quite effective for the analysis of power transmission lines. It can discriminate the fault type, identify the faulty phase of the line, and locate the point of the fault. Faults are located with errors not more than 0.45%. Moreover, the time difference between the actual fault and the calculated fault obtained from the estimated location is not more than 0.004 s. Simulations are claimed to be executed in less computational time, ensuring effective and rapid protection against faults.
Estimation of fault classification and location in a multi-terminal high voltage direct current (MT–HVdc) transmission system is a challenging problem and is considered to be a fundamental maneuver of dc grid protection. This research paper critically reviews traveling and non-travelling wave methods of classification and location of dc faults in multi-terminal HVdc transmission systems. Detailed mathematical analysis of MT–HVdc systems composed of high grounding resistance, cable and overhead line segments, and bipolar coupled transmission network under healthy and faulty conditions, are evaluated. The gravity of this research paper addresses benefits and shortcomings of traveling and non-traveling wave methods and futuristic techniques of fault classification and location.
30 November 2020 in Mathematical Problems in Engineering
Switched reluctance motor is acquiring major attention because of its simple design, economic development, and reduced dependability. These attributes make switched reluctance motors superior to other variable speed machines. The major challenge associated with the development of a switched reluctance motor is its high torque ripple. Torque ripple produces noise and vibration, resulting in degradation of its performance. Various techniques are developed to cope with torque ripples. Practically, there exists not a single mature technique for the minimization of torque ripples in switched reluctance motors. In this research, a switched reluctance motor is modelled and analysed. Its speed and current control are implemented through artificial neural networks. Artificial neural network is found to be a promising technique as compared with other techniques because of its accuracy, reduced complexity, stability, and generalization. The Levenberg–Marquardt algorithm is utilized in artificial neural networks due to its fast and stable convergence for training and testing. It is found from research that artificial neural network-based improved control shows better performance of the switched reluctance motor. Realization of this technique is further validated from its mean square error analysis. Operating parameters of the switched reluctance motor are improved significantly. Simulation environment is created in Matlab/Simulink.