Jean-Louis Gonzalez

Dr. Jean-Louis Gonzalez

Ifremer, LITTORAL, Environmental Resources Laboratory (Provence-Azur-Corse), Zone Portuaire de Brégaillon, 83507 La Seyne/mer, France

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MRMarta Rodrigo
Marta Rodrigo
VGVanessa Millán Gabet
Vanessa Millán Gabet
JGJean-Louis Gonzalez
Jean-Louis Gonzalez
The presence of ten metals (Cd, Ni, Pb, Cr, Cu, Zn, Al, Fe, Mn, and Co) was investigated in the final discharge of six facilities, including four wastewater treatment plants, which were continuously discharging treated wastewater to the coastal environment in Gran Canaria Island. A four-day sampling campaign was carried out at each facility in July 2020, in which both the spot samplings technique and the diffusive gradient in thin-film technique (DGT) were carried out to measure total dissolved metals and the in situ labile metal fraction, respectively. After the necessary sample preparation steps, measurements were carried out by ICP-MS for both samplings. Raw data referred to the spot total dissolved and DGT-labile metal concentrations were reported. In general, the average metal concentrations were dispersed in a broad range. As expected, the highest metal contents were found in those facilities with larger industrial contributions. The values of annual average environmental quality standards (AA-EQS) were used to assess the total dissolved metal concentrations for every metal in every final discharge. In only one of the studied facilities, some metals (Ni and Zn) exceeded these EQS within the receiving waterbody, highlighting the need for more efficient treatment targeted towards a specific discharging-water quality. In addition, the total dissolved and labile metal daily fluxes of discharge were calculated to estimate the contribution of every effluent to the receiving water bodies.

14 July 2021 in ARPHA Preprints
Verified
Preprint
Open access
PDF file
VGVanessa Millán Gabet
Vanessa Millán Gabet
MRMarta Rodrigo
Marta Rodrigo
IAIsabelle Amouroux
Isabelle Amouroux
MBMaria Jesus Belzunce
Maria Jesus Belzunce
PBPhilippe Bersuder
Philippe Bersuder
HZHao Zhang
Hao Zhang
This good practice guide is focused on the DGT devices, which are the most widely used passive sampler for metals, covering the following aspects: ■ Principle ■ Handling passive sampling devices for metals ■ Estimation of appropriate field deployment time ■ A Good Practice Guide for the Use of DGTs ■ Passive sampling device preparation and assembly ■ Selection of sampling site and safety precautions ■ Passive sampling device deployment and retrieval ■ Extraction of analytes from passive sampling devices ■ Analysis ■ Calculations