Bruno Oliveira

Mr. Bruno Oliveira

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
HTHelena R. Torres
Helena R. Torres
Sandro QueirósSandro Queirós
Sandro Queirós
Pedro MoraisPedro Morais
Pedro Morais
BOBruno Oliveira
Bruno Oliveira
JFJaime Francisco Cruz Fonseca
Jaime Francisco Cruz Fonseca
João L. VilaçaJoão L. Vilaça
João L. Vilaça


14 January 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BOBruno Oliveira
Bruno Oliveira
HTHelena R. Torres
Helena R. Torres
PMPedro Morais
Pedro Morais
FVFernando Veloso
Fernando Veloso
ABAntónio L. Baptista
António L. Baptista
João L. VilaçaJoão L. Vilaça
João L. Vilaça
Chronic Venous Disorders (CVD) of the lower limbs are one of the most prevalent medical conditions, affecting 35% of adults in Europe and North America. Due to the exponential growth of the aging population and the worsening of CVD with age, it is expected that the healthcare costs and the resources needed for the treatment of CVD will increase in the coming years. The early diagnosis of CVD is fundamental in treatment planning, while the monitoring of its treatment is fundamental to assess a patient’s condition and quantify the evolution of CVD. However, correct diagnosis relies on a qualitative approach through visual recognition of the various venous disorders, being time-consuming and highly dependent on the physician’s expertise. In this paper, we propose a novel automatic strategy for the joint segmentation and classification of CVDs. The strategy relies on a multi-task deep learning network, denominated VENet, that simultaneously solves segmentation and classification tasks, exploiting the information of both tasks to increase learning efficiency, ultimately improving their performance. The proposed method was compared against state-of-the-art strategies in a dataset of 1376 CVD images. Experiments showed that the VENet achieved a classification performance of 96.4%, 96.4%, and 97.2% for accuracy, precision, and recall, respectively, and a segmentation performance of 75.4%, 76.7.0%, 76.7% for the Dice coefficient, precision, and recall, respectively. The joint formulation increased the robustness of both tasks when compared to the conventional classification or segmentation strategies, proving its added value, mainly for the segmentation of small lesions.

7 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NCNuno Costa
Nuno Costa
LFLuís Ferreira
Luís Ferreira
AAAugusto Righetti Vieira Ferreira de Araújo
Augusto Righetti Vieira Ferreira de Araújo
BOBruno Oliveira
Bruno Oliveira
HTHelena R. Torres
Helena R. Torres
João L. VilaçaJoão L. Vilaça
João L. Vilaça
Breast cancer is the most prevalent cancer in the world and the fifth-leading cause of cancer-related death. Treatment is effective in the early stages. Thus, a need to screen considerable portions of the population is crucial. When the screening procedure uncovers a suspect lesion, a biopsy is performed to assess its potential for malignancy. This procedure is usually performed using real-time Ultrasound (US) imaging. This work proposes a visualization system for US breast biopsy. It consists of an application running on AR glasses that interact with a computer application. The AR glasses track the position of QR codes mounted on an US probe and a biopsy needle. US images are shown in the user’s field of view with enhanced lesion visualization and needle trajectory. To validate the system, latency of the transmission of US images was evaluated. Usability assessment compared our proposed prototype with a traditional approach with different users. It showed that needle alignment was more precise, with 92.67 ± 2.32° in our prototype versus 89.99 ± 37.49° in a traditional system. The users also reached the lesion more accurately. Overall, the proposed solution presents promising results, and the use of AR glasses as a tracking and visualization device exhibited good performance.

29 May 2023 in Heliyon
Verified
Journal Article
Open access
PLPedro Lobo
Pedro Lobo
João L. VilaçaJoão L. Vilaça
João L. Vilaça
HTHelena R. Torres
Helena R. Torres
BOBruno Oliveira
Bruno Oliveira
Alberto SimõesAlberto Simões
Alberto Simões
The daily monitoring of the physiological parameters is essential for monitoring health condition and to prevent health problems. This is possible due to the democratization of numerous types of medical devices and promoted by the interconnection between these and smartphones. Nevertheless, medical devices that connect to smartphones are typically limited to manufacturers applications. This paper proposes an intelligent scanning system to simplify the collection of data displayed on different medical devices screens, recognizing the values, and optionally integrating them, through open protocols, with centralized databases. To develop this system, a dataset comprising 1614 images of medical devices was created, obtained from manufacturer catalogs, photographs and other public datasets. Then, three object detector algorithms (yolov3, Single-Shot Detector [SSD] 320 × 320 and SSD 640 × 640) were trained to detect digits and acronyms/units of measurements presented by medical devices. These models were tested under 3 different conditions to detect digits and acronyms/units as a single object (single label), digits and acronyms/units as independent objects (two labels), and digits and acronyms/units individually (fifteen labels). Models trained for single and two labels were completed with a convolutional neural network (CNN) to identify the detected objects. To group the recognized digits, a condition-tree based strategy on density spatial clustering was used. The most promising approach was the use of the SSD 640 × 640 for fifteen labels. Lastly, as future work, it is intended to convert this system to a mobile environment to accelerate and streamline the process of inserting data into mobile health (mhealth) applications.

22 March 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
FVFernando Veloso
Fernando Veloso
DMDaniel Miranda
Daniel Miranda
Pedro MoraisPedro Morais
Pedro Morais
HTHelena R. Torres
Helena R. Torres
BOBruno Oliveira
Bruno Oliveira
João L. VilaçaJoão L. Vilaça
João L. Vilaça
Deformational plagiocephaly is a head deformity that occurs in newborns, treated in severe cases with helmets named cranial remodeling orthoses (CRO). Current CROs can fail to adapt to head growth, causing excessive pressure sores and other complications, and may lead to poor clinical results. In this work, we experimentally and numerically study the compressive behavior of a functionally graded lattice that may be used in future work as a potential inner lining for a CRO with a customized density distribution. This work is divided into five stages. First, we describe the design of all lattices involved in the study. Second, we measure the mechanical properties of the bulk material used in the manufacturing of the lattices. Third, we study the effect of unit cell size variation, testing three homogenous body-centered cubic (BCC) lattices, and creating a numerical model for the prediction of the compressive behavior of various lattices with different unit cell sizes. Fourth, we study the effects of truss diameter variation, designing and testing three homogenous lattices with different truss diameters. Finally, we design a BCC lattice with a truss diameter gradient and analyze compressive deformations in numerical and experimental compression studies. The numerical simulations of the compression of the homogenous and graded lattices agree with the experimental measurements, both in unit cell variation and in truss diameter variation. In the graded lattice, the compression displacements observed in each region are proportional to their density and agree with the numerical simulation. Truss diameter variation was found to have a wider range of compressive responses than unit cell size variation without major changes in the overall geometry of the lattice and found more suitable for the intended application. The studies showed the potential of the functionally graded lattice for use in the CRO.