Breast cancer is the most prevalent cancer in the world and the fifth-leading cause of cancer-related death. Treatment is effective in the early stages. Thus, a need to screen considerable portions of the population is crucial. When the screening procedure uncovers a suspect lesion, a biopsy is performed to assess its potential for malignancy. This procedure is usually performed using real-time Ultrasound (US) imaging. This work proposes a visualization system for US breast biopsy. It consists of an application running on AR glasses that interact with a computer application. The AR glasses track the position of QR codes mounted on an US probe and a biopsy needle. US images are shown in the user’s field of view with enhanced lesion visualization and needle trajectory. To validate the system, latency of the transmission of US images was evaluated. Usability assessment compared our proposed prototype with a traditional approach with different users. It showed that needle alignment was more precise, with 92.67 ± 2.32° in our prototype versus 89.99 ± 37.49° in a traditional system. The users also reached the lesion more accurately. Overall, the proposed solution presents promising results, and the use of AR glasses as a tracking and visualization device exhibited good performance.
4 November 2020 in IEEE Journal of Biomedical and Health Informatics
Landmark labeling in 3D head surfaces is an important and routine task in clinical practice to evaluate head shape, namely to analyze cranial deformities or growth evolution. However, manual labeling is still applied, being a tedious and time-consuming task, highly prone to intra-/inter-observer variability, and can mislead the diagnose. Thus, automatic methods for anthropometric landmark detection in 3D models have a high interest in clinical practice. In this paper, a novel framework is proposed to accurately detect landmarks in 3D infant's head surfaces. The proposed method is divided into two stages: (i) 2D representation of the 3D head surface; and (ii) landmark detection through a deep learning strategy. Moreover, a 3D data augmentation method to create shape models based on the expected head variability is proposed. The proposed framework was evaluated in synthetic and real datasets, achieving accurate detection results. Furthermore, the data augmentation strategy proved its added value, increasing the method's performance. Overall, the obtained results demonstrated the robustness of the proposed method and its potential to be used in clinical practice for head shape analysis.
19 November 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Renal ultrasound imaging is the primary imaging modality for the assessment of the kidney’s condition and is essential for diagnosis, treatment and surgical intervention planning, and follow-up. In this regard, kidney delineation in three-dimensional ultrasound images represents a relevant and challenging task in clinical practice. In this paper, a novel framework is proposed to accurately segment the kidney in 3D ultrasound images. The proposed framework can be divided into two stages: 1) initialization of the segmentation method; and 2) kidney segmentation. Within the initialization stage, a phase-based feature detection method is used to detect edge points at kidney boundaries, from which the segmentation is automatically initialized. In the segmentation stage, the B-Spline Explicit Active Surface framework is adapted to obtain the final kidney contour. Here, a novel hybrid energy functional that combines localized region-based and edge-based terms is used during segmentation. For the edge term, a fast signed phase-based detection approach is applied. The proposed framework was validated in two distinct datasets: (1) 15 3D challenging poor-quality ultrasound images used for experimental development, parameters assessment, and evaluation; and (2) 42 3D ultrasound images (both healthy and pathologic kidneys) used to unbiasedly assess its accuracy. Overall, the proposed method achieved a Dice overlap around 81% and an average point-to-surface error of ~2.8 mm. These results demonstrate the potential of the proposed method for clinical usage.