BACKGROUND: Covered stent correction for a sinus venosus atrial septal defect (SVASD) was first performed in 2009. This innovative approach was initially viewed as experimental and was reserved for highly selected patients with unusual anatomic variants. In 2016, increasing numbers of procedures began to be performed, and in several centers, it is now offered as a standard of care option alongside surgical repair. However, covered stent correction for SVASD is not recognized by regulatory authorities, and in the minds of many pediatric and adult congenital cardiologists and surgeons, the condition is viewed as treatable only by cardiac surgery with cardiopulmonary bypass. METHODS: In April 2023, all centers identified from international conferences, publications, and colleague networks to be undertaking covered stent correction for SVASD were invited to participate in a retrospective audit of their procedures. RESULTS: Data were received on 381 patients from 54 units over a 12-year period with 90% of procedures being performed over the past 5 years. Balloon-expandable stents (8 types) were used in the majority; self-expanding stents (4 types) were used in 4.5%. The commonest stent was the 10-zig covered Cheatham Platinum stent in 62% of cases. In 10 procedures, the stent embolized requiring surgical retrieval and repair of the defect, resulting in technically successful implantation in 371 of 381 (97.4%). Major complications (surgical drainage of tamponade, pacemaker implantation, surgery for pulmonary vein occlusion, and late stent removal) occurred in 5 patients (1.3%). Repeat catheterization to correct residual leaks was required in 7 patients (1.8%). Thus, 359 of 381 patients (94.2%) had successful correction without major complications or additional catheter interventions. CONCLUSIONS: This article details the exponential uptake of covered stent correction for SVASD during the past 5 years. Cardiopulmonary bypass was avoided in the majority of patients, and major complications were infrequent. Prospective registries with standardized definitions, inclusion criteria, and follow-up and comparative studies with surgery are now required to help support the extension of covered stent correction as an alternative standard-of-care option for patients with an SVASD.
The intricate nature of congenital heart disease requires understanding of the complex, patient-specific three-dimensional dynamic anatomy of the heart, from imaging data such as three-dimensional echocardiography for successful outcomes from surgical and interventional procedures. Conventional clinical systems use flat screens, and therefore, display remains two-dimensional, which undermines the full understanding of the three-dimensional dynamic data. Additionally, the control of three-dimensional visualisation with two-dimensional tools is often difficult, so used only by imaging specialists. In this paper, we describe a virtual reality system for immersive surgery planning using dynamic three-dimensional echocardiography, which enables fast prototyping for visualisation such as volume rendering, multiplanar reformatting, flow visualisation and advanced interaction such as three-dimensional cropping, windowing, measurement, haptic feedback, automatic image orientation and multiuser interactions. The available features were evaluated by imaging and nonimaging clinicians, showing that the virtual reality system can help improve the understanding and communication of three-dimensional echocardiography imaging and potentially benefit congenital heart disease treatment.
Echocardiography, CT and MRI have a crucial role in the management of congenital heart disease (CHD) patients. All of these modalities can be presented in a 2D or a 3D rendered format. The aim of this paper is to review the key advantages and potential limitations, as well as the future challenges of a 3D approach in each imaging modality. The focus of this review is on anatomic rather than functional assessment. Conventional 2D echocardiography presents limitations when imaging complex lesions, whereas 3D imaging depicts the anatomy in all dimensions. CT and MRI can visualise extracardiac vasculature and guide complex biventricular repair. Three-dimensional printed models can be used in depicting complex intracardiac relationships and defining the surgical strategy in specific lesions. Extended reality imaging retained dynamic cardiac motion holds great potential for planning surgical and catheter procedures. Overall, the use of 3D imaging has resulted in a better understanding of anatomy, with a direct impact on the surgical and catheter approach, particularly in more complex cases.
Purpose of Review: To provide an overview of fluoroscopy-free transcatheter atrial septal defect (ASD) closure and introduce a simplified approach that avoids pulmonary vein instrumentation. Recent Findings: Since the first reported fluoroscopy-free ASD closure 24 years ago, only a few small series have described this technique. We present a simplified and less cumbersome approach to encourage wider adoption of the fluoroscopy-free method to suitable ASD anatomy. Results: Fluoroscopy free ASD closure was performed in 9 patients using the conventional technique (Group 1) and 23 patients using our simplified approach of direct placement of the device into the defect (Group 2). Median age and weight were 28 years, 53 kg in Group 1 (range: 5–52 years, 22–88 kg) and 36 years, 66 kg in Group 2 (range: 4–76 years, 16–115 kg). Devices were successfully implanted in all patients, with a median device size of 21 mm (Group 1: 9–36 mm, Group 2: 10–33 mm). Procedural time was 47 min for Group 1 and 35 min for Group 2 ( p = 0.09). Length of hospital stay was similar in both groups. There were no acute or long-term complications and no need for reintervention. Summary: Transcatheter ASD closure without the use of fluoroscopy using the simplified approach is safe and effective, offers a shorter procedure duration and minimises instrumentation within the left atrium and pulmonary veins. Patient selection is key and with greater experience, this procedure may be applicable to a wider selection of ASD anatomy.