Baojun Zhao

Baojun Zhao


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2021 in Crystals
Verified
Journal Article
Open access
PDF file
Dong Chen Dong ChenDong Chen Dong Chen
Dong Chen Dong Chen
PLPengkun Li
Pengkun Li
CBCHENG Baoquan
CHENG Baoquan
Huihua ChenHuihua Chen
Huihua Chen
QWQiong Wang
Qiong Wang
BZBaojun Zhao
Baojun Zhao
GRC-PC wall is a new type of integrated composite exterior wall with decorative and structural functions. It is formed by superimposing GRC surface layer on the outer leaf of prefabricated PC wall. Due to the complexity of indoor and outdoor environment and the difference of shrinkage performance between concrete and GRC materials, GRC surface layer in GRC-PC wall is prone to shrinkage and cracking, among which, the connection modes between GRC layer and PC layer and change of temperature and humidity have the greatest influence. Therefore, GRC material formula was adjusted, and seven experimental panels were produced. In view of the temperature and the humidity changes in different indoor and outdoor environments, the influences of different connection modes between GRC layer and PC layer on the material shrinkage performance were studied, and a one year material shrinkage performance experiment was conducted. The results show that, in indoor environment, the shrinkage of GRC layer and PC layer is relatively gentle due to the small range of temperature and humidity change. Compared with the indoor environment, the changes of outdoor temperature and humidity are more drastic. The shrinkage changes of GRC layer and PC layer show great fluctuations, but the overall strain value is still within a reasonable range, and there is no crack. At the same time, this suggests that smooth interface is more conducive to crack resistance of GRC surface layer compared with different interface types between GRC layer and PC layer. The research provides an experimental basis for the large-scale application of the wall panel, and it has great advantages in improving the efficiency of prefabricated building construction.

16 January 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XHXiaoyi Hu
Xiaoyi Hu
BZBaojun Zhao
Baojun Zhao
Hao WuHao Wu
Hao Wu
ADAbderrahim DJERRAD
Abderrahim DJERRAD
DZDekai Zhang
Dekai Zhang
Prefabricated structures are widely used because of their advantages of energy savings, environmental protection, standardization, and universality. However, due to the complex structure of the joints, it is easy to make the joint installation difficult and the prefabricated column connection unreliable, and further lead to the poor seismic performance of the structure. Therefore, a new type of dry sleeve joint with double screw sleeve without support is proposed, and the seismic performance and influencing factors of the new dry-sleeve-joint prefabricated column are studied. This study encompasses seven reinforced concrete columns characterized by cross-sectional dimensions of 600 mm × 600 mm. Among these, five specimens feature a novel dry sleeve connection, while the remaining two specimens were entirely cast-in-place. Low-cycle reversed loading experiments were conducted on all specimens to analyze and compare the damage patterns, hysteresis curves, skeleton curves, displacement ductility, energy dissipation capacity, and ultimate bearing capacity between precast and cast-in-place columns. Several parameters, including fabrication method, axial compression ratio, longitudinal reinforcement diameter, and hoop spacing, were examined. The findings demonstrated that the calculated-to-tested ratio of the ultimate bearing capacity for the prefabricated specimens was determined to be 0.62, indicating a high level of safety. The displacement ductility coefficient for each specimen ranged from 2.43 to 3.31, while the ultimate drift ratio was within the range of 1/41 to 1/33, satisfying the specified requirements for seismic performance. However, the hysteresis curve of the prefabricated specimens exhibited a pinching effect, which may be related to the existence of a weak layer on the joint surface of the post-cast section. In general, the shape of the new dry sleeve is maintained in the test, the connection form can effectively transfer the force, and the longitudinal bars can be strained and yield when the prefabricated column reaches the peak load. The new type of dry sleeve connection can be used for longitudinal reinforcement connection of reinforced concrete columns with seismic design.