HE SHENG CHOU

Dr. HE SHENG CHOU


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CLChun-Wei Li
Chun-Wei Li
SLSzu-Yin Lin
Szu-Yin Lin
HCHE SHENG CHOU
HE SHENG CHOU
TCTsung-Yi Chen
Tsung-Yi Chen
YCYu-An Chen
Yu-An Chen
WLWen-Shen Lo
Wen-Shen Lo
Apical lesions, the general term for chronic infectious diseases, are very common dental diseases in modern life, and are caused by various factors. The current prevailing endodontic treatment makes use of X-ray photography taken from patients where the lesion area is marked manually, which is therefore time consuming. Additionally, for some images the significant details might not be recognizable due to the different shooting angles or doses. To make the diagnosis process shorter and efficient, repetitive tasks should be performed automatically to allow the dentists to focus more on the technical and medical diagnosis, such as treatment, tooth cleaning, or medical communication. To realize the automatic diagnosis, this article proposes and establishes a lesion area analysis model based on convolutional neural networks (CNN). For establishing a standardized database for clinical application, the Institutional Review Board (IRB) with application number 202002030B0 has been approved with the database established by dentists who provided the practical clinical data. In this study, the image data is preprocessed by a Gaussian high-pass filter. Then, an iterative thresholding is applied to slice the X-ray image into several individual tooth sample images. The collection of individual tooth images that comprises the image database are used as input into the CNN migration learning model for training. Seventy percent (70%) of the image database is used for training and validating the model while the remaining 30% is used for testing and estimating the accuracy of the model. The practical diagnosis accuracy of the proposed CNN model is 92.5%. The proposed model successfully facilitated the automatic diagnosis of the apical lesion.

5 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
奕毛奕程 毛
奕程 毛
TCTsung-Yi Chen
Tsung-Yi Chen
HCHE SHENG CHOU
HE SHENG CHOU
SLSzu-Yin Lin
Szu-Yin Lin
SLSheng-Yu Liu
Sheng-Yu Liu
WCWei-Yuan Chiang
Wei-Yuan Chiang
Caries is a dental disease caused by bacterial infection. If the cause of the caries is detected early, the treatment will be relatively easy, which in turn prevents caries from spreading. The current common procedure of dentists is to first perform radiographic examination on the patient and mark the lesions manually. However, the work of judging lesions and markings requires professional experience and is very time-consuming and repetitive. Taking advantage of the rapid development of artificial intelligence imaging research and technical methods will help dentists make accurate markings and improve medical treatments. It can also shorten the judgment time of professionals. In addition to the use of Gaussian high-pass filter and Otsu’s threshold image enhancement technology, this research solves the problem that the original cutting technology cannot extract certain single teeth, and it proposes a caries and lesions area analysis model based on convolutional neural networks (CNN), which can identify caries and restorations from the bitewing images. Moreover, it provides dentists with more accurate objective judgment data to achieve the purpose of automatic diagnosis and treatment planning as a technology for assisting precision medicine. A standardized database established following a defined set of steps is also proposed in this study. There are three main steps to generate the image of a single tooth from a bitewing image, which can increase the accuracy of the analysis model. The steps include (1) preprocessing of the dental image to obtain a high-quality binarization, (2) a dental image cropping procedure to obtain individually separated tooth samples, and (3) a dental image masking step which masks the fine broken teeth from the sample and enhances the quality of the training. Among the current four common neural networks, namely, AlexNet, GoogleNet, Vgg19, and ResNet50, experimental results show that the proposed AlexNet model in this study for restoration and caries judgments has an accuracy as high as 95.56% and 90.30%, respectively. These are promising results that lead to the possibility of developing an automatic judgment method of bitewing film.

18 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SCShih-Lun Chen
Shih-Lun Chen
HCHE SHENG CHOU
HE SHENG CHOU
CHChun-Hsiang Huang
Chun-Hsiang Huang
CCChih-Yun Chen
Chih-Yun Chen
LLLiang-Yu Li
Liang-Yu Li
JHJe-Sheng Huang
Je-Sheng Huang
Global precipitation is becoming increasingly intense due to the extreme climate. Therefore, creating new technology to manage water resources is crucial. To create a sustainable urban and ecological environment, a water level and water quality control system implementing artificial intelligence is presented in this research. The proposed smart monitoring system consists of four sensors (two different liquid level sensors, a turbidity and pH sensor, and a water oxygen sensor), a control module (an MCU, a motor, a pump, and a drain), and a power and communication system (a solar panel, a battery, and a wireless communication module). The system focuses on low-cost Internet of Things (IoT) devices along with low power consumption and high precision. This proposal collects rainfall from the preceding 10 years in the application region as well as the region’s meteorological bureau’s weekly weather report and uses artificial intelligence to compute the appropriate water level. More importantly, the adoption of dynamic adjustment systems can reserve and modify water resources in the application region more efficiently. Compared to existing technologies, the measurement approach utilized in this study not only achieves cost savings exceeding 60% but also enhances water level measurement accuracy by over 15% through the successful implementation of water level calibration decisions utilizing multiple distinct sensors. Of greater significance, the dynamic adjustment systems proposed in this research offer the potential for conserving water resources by more than 15% in an effective manner. As a result, the adoption of this technology may efficiently reserve and distribute water resources for smart cities as well as reduce substantial losses caused by anomalous water resources, such as floods, droughts, and ecological concerns.

14 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYen-Cheng Huang
Yen-Cheng Huang
CCChiung-An Chen
Chiung-An Chen
TCTsung-Yi Chen
Tsung-Yi Chen
HCHE SHENG CHOU
HE SHENG CHOU
WLWei-Chi Lin
Wei-Chi Lin
WLWen-Shen Lo
Wen-Shen Lo
This paper presents a novel method for automatic segmentation of dental X-ray images into single tooth sections and for placing every segmented tooth onto a precise corresponding position table. Moreover, the proposed method automatically determines the tooth’s position in a panoramic X-ray film. The image-processing step incorporates a variety of image-enhancement techniques, including sharpening, histogram equalization, and flat-field correction. Moreover, image processing was implemented iteratively to achieve higher pixel value contrast between the teeth and cavity. The next image-enhancement step is aimed at detecting the teeth cavity and involves determining the segment and points separating the upper and lower jaw, using the difference in pixel values to cut the image into several equal sections and then connecting each cavity feature point to extend a curve that completes the description of the separated jaw. The curve is shifted up and down to look for the gap between the teeth, to identify and address missing teeth and overlapping. Under FDI World Dental Federation notation, the left and right sides receive eight-code sequences to mark each tooth, which provides improved convenience in clinical use. According to the literature, X-ray film cannot be marked correctly when a tooth is missing. This paper utilizes artificial center positioning and sets the teeth gap feature points to have the same count. Then, the gap feature points are connected as a curve with the curve of the jaw to illustrate the dental segmentation. In addition, we incorporate different image-processing methods to sequentially strengthen the X-ray film. The proposed procedure had an 89.95% accuracy rate for tooth positioning. As for the tooth cutting, where the edge of the cutting box is used to determine the position of each tooth number, the accuracy of the tooth positioning method in this proposed study is 92.78%.

9 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
SCShih-Lun Chen
Shih-Lun Chen
HCHE SHENG CHOU
HE SHENG CHOU
YCYueh Chuo
Yueh Chuo
LYLin Yuan-Jin
Lin Yuan-Jin
TTTzu-Hsiang Tsai
Tzu-Hsiang Tsai
TCTsung-Yi Chen
Tsung-Yi Chen
In recent years, there has been a significant increase in collaboration between medical imaging and artificial intelligence technology. The use of automated techniques for detecting medical symptoms has become increasingly prevalent. However, there has been a lack of research on the relationship between impacted teeth and the inferior alveolar nerve (IAN) in DPR images. The severe compression of teeth against the IAN may necessitate the requirement for nerve canal treatment. To reduce the occurrence of such events, this study aims to develop an auxiliary detection system capable of precisely locating the relative positions of the IAN and impacted teeth through object detection and image enhancement. This system is designed to shorten the duration of examinations for dentists while concurrently mitigating the chances of diagnostic errors. The innovations in this research are as follows: (1) using YOLO_v4 to identify impacted teeth and the IAN in DPR images achieves an accuracy of 88%. However, the developed algorithm in this study achieves an accuracy of 93%. (2) Image enhancement is utilized in this study to expand the dataset, with an accuracy of up to 2~3% enhancement in detecting diseases. (3) The segmentation technique proposed in this study surpasses previous methods by achieving 6% higher accuracy in dental diagnosis.

1 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SCShih-Lun Chen
Shih-Lun Chen
HCHE SHENG CHOU
HE SHENG CHOU
SKShih-Yao Ke
Shih-Yao Ke
CCChiung-An Chen
Chiung-An Chen
TCTsung-Yi Chen
Tsung-Yi Chen
Kuo-chen LiKuo-chen Li
Kuo-chen Li
It has always been a major issue for a hospital to acquire real-time information about a patient in emergency situations. Because of this, this research presents a novel high-compression-ratio and real-time-process image compression very-large-scale integration (VLSI) design for image sensors in the Internet of Things (IoT). The design consists of a YEF transform, color sampling, block truncation coding (BTC), threshold optimization, sub-sampling, prediction, quantization, and Golomb–Rice coding. By using machine learning, different BTC parameters are trained to achieve the optimal solution given the parameters. Two optimal reconstruction values and bitmaps for each 4 × 4 block are achieved. An image is divided into 4 × 4 blocks by BTC for numerical conversion and removing inter-pixel redundancy. The sub-sampling, prediction, and quantization steps are performed to reduce redundant information. Finally, the value with a high probability will be coded using Golomb–Rice coding. The proposed algorithm has a higher compression ratio than traditional BTC-based image compression algorithms. Moreover, this research also proposes a real-time image compression chip design based on low-complexity and pipelined architecture by using TSMC 0.18 μm CMOS technology. The operating frequency of the chip can achieve 100 MHz. The core area and the number of logic gates are 598,880 μm2 and 56.3 K, respectively. In addition, this design achieves 50 frames per second, which is suitable for real-time CMOS image sensor compression.