Anselmo Agostinho Simionato

Dr. Anselmo Agostinho Simionato

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Medicina
Verified
Journal Article
Open access
PDF file
ESEbele Adaobi Silva
Ebele Adaobi Silva
Anselmo Agostinho SimionatoAnselmo Agostinho Simionato
Anselmo Agostinho Simionato
AFAdriana Cláudia Lapria Faria
Adriana Cláudia Lapria Faria
Estevam A. A BonfanteEstevam A. A Bonfante
Estevam A. A Bonfante
RRRenata Cristina Silveira Rodrigues
Renata Cristina Silveira Rodrigues
Ricardo Faria RibeiroRicardo Faria Ribeiro
Ricardo Faria Ribeiro
Background and Objectives: There are limited data regarding the behavior of resin matrix ceramics for current CAD-CAM materials. Further studies may be beneficial and can help clinicians planning to use these materials during prosthodontic rehabilitation. The aim of this study was to evaluate and compare the flexural strength and strain distributions, filler content, wear, and reliability of two resin matrix ceramic CAD-CAM materials. Materials and Methods: Two resin matrix ceramics, Ambarino High-Class (AH) and Vita Enamic (VE), were tested for flexural strength (n = 24), wear (n = 10), and reliability (n = 18). Thermogravimetric analysis was used to determine the percentage of filler by weight, and digital image correlation (DIC) was used for strain analysis in flexural strength test. Reliability of each resin matrix ceramic was compared after accelerated lifetime testing of crowns using a two-parameter Weibull distribution. Data of flexural strength, wear, and thermogravimetry were analyzed by independent t-tests with significance level at 5%. Results: The results of DIC analysis were analyzed by a qualitative comparison between the images obtained. The materials tested showed different flexural strength (p < 0.05) and strain distributions. The filler content was the same as informed by manufacturers. No difference was observed in the wear or reliability analysis (p > 0.05). The flexural strength of material AH was superior to VE, and the strain distribution was compatible with this finding. Conclusions: The two resin matrix ceramics tested showed similar behavior in wear and reliability analysis. Both can provide safe use for dental crowns.

1 February 2023 in Brazilian Dental Journal
Verified
Journal Article
Open access
Anselmo Agostinho SimionatoAnselmo Agostinho Simionato
Anselmo Agostinho Simionato
RVRocío Geng Vivanco
Rocío Geng Vivanco
RTRafaella Tonani-Torrieri
Rafaella Tonani-Torrieri
CACarolina Noronha Ferraz de Arruda
Carolina Noronha Ferraz de Arruda
FPFernanda Carvalho Panzeri Pires-De-Souza
Fernanda Carvalho Panzeri Pires-De-Souza
The aim of this in situ study was to evaluate color change, surface roughness, gloss, and microhardness in tooth enamel submitted to whitening and remineralizing toothpastes. Fifteen healthy adults (REBEC - RBR-7p87yr) (with unstimulated salivary flow ≥ 1.5 ml for 5 minutes, pH=7) wore two intraoral devices containing four bovine dental fragments (6 x 6 x 2 mm). Participants were randomly assigned and instructed to toothbrush the devices with the tested toothpastes (30 days): CT: conventional; WT: whitening; WTP: whitening with peroxide, and RT: remineralizing toothpaste. A washout period of 7 days was established. Readouts of color, gloss, surface roughness, and microhardness were performed before and after brushing. The results demonstrated no color, gloss, and microhardness differences (p>0.5). The samples brushed with WTP (0.2(0.7) showed higher surface roughness (p=0.0493) than those with WT (-0.5(1.0). The toothpastes did not alter the properties of the dental enamel, except for the roughness. Toothpaste with an abrasive system based on sodium bicarbonate and silica, and that contains sodium carbonate peroxide increased the surface roughness of the enamel.

13 November 2024 in Journal of Dentistry
Verified
Journal Article
Closed access
SCSarah Ribeiro Cruz-Araujo
Sarah Ribeiro Cruz-Araujo
MSManuel António Sampaio-Fernandes
Manuel António Sampaio-Fernandes
BFBruna N de Freitas
Bruna N de Freitas
Anselmo Agostinho SimionatoAnselmo Agostinho Simionato
Anselmo Agostinho Simionato
MFMaria Helena Figueiral
Maria Helena Figueiral
Ana Paula MacedoAna Paula Macedo
Ana Paula Macedo

30 April 2025 in Dental and Medical Problems
Verified
Journal Article
Open access
ESEbele Adaobi Silva
Ebele Adaobi Silva
Anselmo Agostinho SimionatoAnselmo Agostinho Simionato
Anselmo Agostinho Simionato
OMOlivia Breda Moss
Olivia Breda Moss
AFAdriana Cláudia Lapria Faria
Adriana Cláudia Lapria Faria
RRRenata Cristina Silveira Rodrigues
Renata Cristina Silveira Rodrigues
Ricardo Faria RibeiroRicardo Faria Ribeiro
Ricardo Faria Ribeiro
Resin-matrix ceramics have been developed to combine the high esthetics of ceramics with the mechanical properties of composite resin. The surface changes of these materials when exposed to highly consumed beverages are still not fully elucidated and need further research. The aim of the present study was to evaluate the color stability, and surface roughness and microhardness of a polymer-infiltrated ceramic network (PICN) (VITA ENAMIC® - VE) and a resin nanoceramic (Ambarino® High-Class - AH), used to obtain computer-aided design/computer-aided manufacturing (CAD/CAM) restorations, after immersion in high-consumption beverages. A total of 96 specimens were prepared (n = 48 per group - VE and AH), further subdivided into 6 groups (n = 8) according to the beverage in which they were immersed. The color change (ΔE00), surface roughness (Ra) and microhardness (KHN) measurements were made before and after immersion in the beverages. The materials presented significant differences in ΔE00 when immersed in distilled water (p = 0.043), coffee (p = 0.010) and red wine (p < 0.001). Acceptable values for ΔE00 were recorded for distilled water and the energy drink with regard to AH, and for the energy drink and orange juice with regard to VE. Regarding the Ra data, the VE samples showed a difference after immersion in all the tested beverages, while AH differed only when immersed in distilled water and the energy drink. Immersion in the beverages seemed to reduce KHN in the tested materials, although significant differences were detected only in the VE samples from the energy drink (p < 0.001) and orange juice (p < 0.001) groups. Based on the results, it can be concluded that the beverages tested may affect the esthetics and surface characteristics of the materials tested.

23 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
Anselmo Agostinho SimionatoAnselmo Agostinho Simionato
Anselmo Agostinho Simionato
ESEmerson de Souza Santos
Emerson de Souza Santos
AFAdriana Cláudia Lapria Faria
Adriana Cláudia Lapria Faria
CNCássio do Nascimento
Cássio do Nascimento
RRRenata Cristina Silveira Rodrigues
Renata Cristina Silveira Rodrigues
Ricardo Faria RibeiroRicardo Faria Ribeiro
Ricardo Faria Ribeiro
The relationship between bacterial infiltration and internal conical Implant-Abutment Interfaces (IAIs) with different conicities still requires investigations that can offer valuable information in the clinical understanding of peri-implant health. The present study aimed to verify the bacterial infiltration of two internal conical connections with an angulation of 11.5° and 16° with the external hexagonal connection as a comparative after thermomechanical cycling using saliva as a contaminant. Test (n = 10) and control (n = 3) groups were set up. Evaluations were made on torque loss, Scanning Electron Microscopy (SEM), and Micro Computerized Tomography (MicroCT) after performing 2 × 106 mechanical cycles (120 N) and 600 thermal cycles (5°–55° C) with 2 mm lateral displacement. The contents of the IAI were collected for microbiological analysis. There was a difference (p < 0.05) in torque loss of the groups tested; groups from the 16° IAI obtained a lower percentage of torque loss. All groups presented contamination and the analysis of the results shows that the microbiological profile of the IAI differs qualitatively from the profile found in the saliva used for contamination. The mechanical loading affects the microbiological profile found in the IAIs (p < 0.05). In conclusion, the IAI environment may favor a microbiological profile different from that of saliva and the thermocycling condition may alter the microbial profile found in the IAI.

19 July 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Ricardo Faria RibeiroRicardo Faria Ribeiro
Ricardo Faria Ribeiro
VMVictor Barboza Mata
Victor Barboza Mata
LTLucas de Oliveira Tomaselli
Lucas de Oliveira Tomaselli
Anselmo Agostinho SimionatoAnselmo Agostinho Simionato
Anselmo Agostinho Simionato
ESEmerson de Souza Santos
Emerson de Souza Santos
CNCássio do Nascimento
Cássio do Nascimento
The objective of this study was to evaluate microbial leakage by means of genome counts, through the implant–abutment interface in dental implants with different Morse taper abutments. Fifty-six samples were prepared and divided in four groups: CMC TB (14 Cylindrical Implants–14 TiBase Abutments), CMX TB (14 Conical Implants–14 TiBase Abutments), CMX PU (14 Conical Implants–14 Universal Abutment) and CMX U (14 Tapered Implants–14 UCLA Abutments). Assemblies had their interface submerged in saliva as the contaminant. Samples were subjected either to thermomechanical cycling (2 × 106 mechanical cycles with frequency of 5 Hz and load of 120 N simultaneously with thermal cycles of 5–55 °C) or thermal cycling (5–55 °C). After cycling, the contents from the inner parts of assemblies were collected and analyzed using the Checkerboard DNA–DNA hybridization technique. Significant differences in the total genome counts were found after both thermomechanical or thermal cycling: CMX U > CMX PU > CMX TB > CMC TB. There were also significant differences in individual bacterial counts in each of the groups (p < 0.05). Irrespective of mechanical cycling, the type of abutment seems to influence not only the total microbial leakage through the interface, but also seems to significantly reflect differences considering individual target species.