Junichiro Wada

Dr. Junichiro Wada

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2022 in Polymers
Verified
Journal Article
Open access
PDF file
JWJunichiro Wada
Junichiro Wada
KWKanae Wada
Kanae Wada
MGMona Gibreel
Mona Gibreel
NWNoriyuki Wakabayashi
Noriyuki Wakabayashi
TITsutomu Iwamoto
Tsutomu Iwamoto
Lippo LassilaLippo Lassila
Lippo Lassila
Although three-dimensional (3D) printing is clinically convenient to fabricate occlusal splints, it is still unclear how the post-curing method and the printer type can affect 3D-printed splints. This study aimed to evaluate the effect of stroboscopic post-curing at a nitrogen gas (N2) atmosphere versus post-curing in an air atmosphere, as well as the printer type (liquid crystal display (LCD) and digital light processing (DLP)) on the mechanical properties of a 3D-printed hard-type occlusal splint material. Flexural strength, flexural modulus, Vickers hardness number (VHN), fracture toughness, degree of double bond conversion (DC), 3D microlayer structure, water sorption, and water solubility were evaluated. The post-curing method significantly affected all evaluated properties except fracture toughness and 3D microlayer structure, while the printer type significantly affected all evaluated properties except flexural strength and flexural modulus. VHN and DC were significantly higher, and the smoother surface was noticeably obtained when printed by LCD printer and post-cured at an N2 atmosphere. The current results suggested that the post-curing method and the printer type would play a role in the mechanical properties of the evaluated material and that the combination of post-curing at an N2 atmosphere and LCD printer could enhance its mechanical properties and surface smoothness.

15 February 2018 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
KNK. Nakamura
K. Nakamura
IMI. Minami
I. Minami
JWJunichiro Wada
Junichiro Wada
YIY. Ikawa
Y. Ikawa
NWN. Wakabayashi
N. Wakabayashi

31 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
JWJunichiro Wada
Junichiro Wada
KWKanae Wada
Kanae Wada
MGMona Gibreel
Mona Gibreel
NWNoriyuki Wakabayashi
Noriyuki Wakabayashi
TITsutomu Iwamoto
Tsutomu Iwamoto
Lippo LassilaLippo Lassila
Lippo Lassila
Despite the fact that three-dimensional (3D) printing is frequently used in the manufacturing of occlusal splints, the effects of the 3D printer type and post-curing methods are still unclear. The aim of this study was to investigate the effect of the printer type (digital light processing: DLP; and liquid crystal display: LCD) as well as the post-curing method with two different atmospheric conditions (air and nitrogen gas (N2)) on the mechanical and surface properties of 3D-printed soft-type occlusal splint material. The evaluated properties were flexural strength, flexural modulus, Vickers hardness (VHN), fracture toughness, degree of double bond conversion (DC%), water sorption, water solubility, and 3D microlayer structure. The printer type significantly affected all the evaluated properties. Flexural strength, flexural modulus, and fracture toughness were significantly higher when specimens were printed by a DLP printer, while VHN and DC% were significantly higher, and a smoother surface was noticeably obtained when printed by an LCD printer. The post-curing at an N2 atmosphere significantly enhanced all of the evaluated properties except water sorption, 3D microlayer structure, and fracture toughness. The current results suggested that the printer type and the post-curing methods would have an impact on the mechanical and surface properties of the evaluated material.

24 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
JWJunichiro Wada
Junichiro Wada
KWKanae Wada
Kanae Wada
Sufyan GaroushiSufyan Garoushi
Sufyan Garoushi
ASAkikazu Shinya
Akikazu Shinya
NWNoriyuki Wakabayashi
Noriyuki Wakabayashi
LLLippo Lassila
Lippo Lassila
Although additive manufacturing has been widely applied for occlusal splint (OS) fabrication, it is still unclear whether 3D printing system and post-curing atmosphere would play a role in the wear resistance of additive-manufactured OS. Therefore, the aim of this study was to evaluate the effect of 3D printing system (liquid crystal display (LCD) and digital light processing (DLP)) and post-curing atmosphere (air and nitrogen gas (N2)) on the wear resistance of hard and soft OS materials for additive-manufactured OSs (KeySplint® Hard and Soft). The evaluated properties were microwear (by two-body wear test) and nano-wear resistances (by nanoindentation wear test) as well as flexural strength and flexural modulus (by three-point bending test), surface microhardness (by Vickers hardness test), and nanoscale elastic modulus (reduced elastic modulus) and nano surface hardness (by nanoindentation test). For the hard material, the surface microhardness, microwear resistance, reduced elastic modulus, nano surface hardness, and nano-wear resistance were significantly affected by the printing system (p < 0.05), while all the evaluated properties except flexural modulus were significantly affected by the post-curing atmosphere (p < 0.05). Meanwhile, both the printing system and post-curing atmosphere significantly affected all the evaluated properties (p < 0.05). The specimens additive-manufactured by DLP printer tended to show higher wear resistance in the hard material groups and lower wear resistance in the soft material groups when compared to those by LCD printer. The post-curing at N2 atmosphere significantly enhanced the microwear resistance of hard material groups additive-manufactured by the DLP printer (p < 0.05) and soft material groups additive-manufactured by the LCD printer (p < 0.01), while it significantly enhanced the nano-wear resistance of both hard and soft material groups regardless of the printing system (p < 0.01). It can be concluded that 3D printing system and post-curing atmosphere affect the micro- and nano-wear resistance of tested additively manufactured OS materials. In addition, it can be also concluded that the optical printing system providing higher wear resistance depends on the material type, and using nitrogen gas as a protection gas during post-curing enhances the wear resistance of tested materials.

30 January 2020 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
TNTomiharu Nagayama
Tomiharu Nagayama
JWJunichiro Wada
Junichiro Wada
CWChie Watanabe
Chie Watanabe
NMNatsuko Murakami
Natsuko Murakami
KTKensuke Takakusaki
Kensuke Takakusaki
NWNoriyuki Wakabayashi
Noriyuki Wakabayashi
The purpose of this study was to investigate the influence of retainers and major connector designs on the stabilization of remaining mobile teeth using removable partial dentures (RPDs). We prepared experimental RPDs with several retainer designs and major connectors for lower Kennedy class I models. The simulated RPD insertion and removal test was conducted and retentive force and mobility of mobile remaining teeth with and without RPD placement were measured throughout a simulation test. Regardless of reduction of retentive force, the placement of RPDs using cast clasps and/or lingual plates resulted in reduced mobility of the remaining teeth than use of wrought wire clasps and/or lingual bars. The results suggested that cast clasps and lingual plates are effective for the stabilization of mobile, remaining teeth. Additionally, the stabilizing effect of RPD on abutment teeth was not diminished, despite decreases in retentive force.

1 January 2018 in BioMed Research International
Verified
Journal Article
Open access
MIManhal Ijbara
Manhal Ijbara
KWKanae Wada
Kanae Wada
MTMakoto Tabata
Makoto Tabata
JWJunichiro Wada
Junichiro Wada
Go InoueGo Inoue
Go Inoue
MMMichiyo Miyashin
Michiyo Miyashin
Enamel wear, which is inevitable due to the process of mastication, is a process in which the microcracking of enamel occurs due to the surface contacting very small hard particles. When these particles slide on enamel, a combined process of microcutting and microcracking in the surface and subsurface of the enamel takes place. The aim of this study was to detect microscopic differences in the microcrack behavior by subjecting enamel specimens derived from different age groups (immature open-apex premolars, mature closed-apex premolars, and deciduous molars) to cycles of simulated impact and sliding wear testing under controlled conditions. Our findings indicated that the characteristics of the microcracks, including the length, depth, count, orientation, and relation to microstructures differed among the study groups. The differences between the surface and subsurface microcrack characteristics were most notable in the enamel of deciduous molars followed by immature premolars and mature premolars whereby deciduous enamel suffered numerous, extensive, and branched microcracks. Within the limitations of this study, it was concluded that enamel surface and subsurface microcracks characteristics are dependent on the posteruptive age with deciduous enamel being the least resistant to wear based on the microcrack behavior as compared to permanent enamel.