Paloma Trueba

Dr. Paloma Trueba

Seville University
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SFSheila Lascano Farak
Sheila Lascano Farak
CACristina Arévalo
Cristina Arévalo
IMIsabel Montealegre-Meléndez
Isabel Montealegre-Meléndez
SMSergio Muñoz Moreno
Sergio Muñoz Moreno
JRJosé Antonio Rodríguez-Ortiz
José Antonio Rodríguez-Ortiz
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
Titanium and its alloys are reference materials in biomedical applications because of their desirable properties. However, one of the most important concerns in long-term prostheses is bone resorption as a result of the stress-shielding phenomena. Development of porous titanium for implants with a low Young’s modulus has accomplished increasing scientific and technological attention. The aim of this study is to evaluate the viability, industrial implementation and potential technology transfer of different powder-metallurgy techniques to obtain porous titanium with stiffness values similar to that exhibited by cortical bone. Porous samples of commercial pure titanium grade-4 were obtained by following both conventional powder metallurgy (PM) and space-holder technique. The conventional PM frontier (Loose-Sintering) was evaluated. Additionally, the technical feasibility of two different space holders (NH4HCO3 and NaCl) was investigated. The microstructural and mechanical properties were assessed. Furthermore, the mechanical properties of titanium porous structures with porosities of 40% were studied by Finite Element Method (FEM) and compared with the experimental results. Some important findings are: (i) the optimal parameters for processing routes used to obtain low Young’s modulus values, retaining suitable mechanical strength; (ii) better mechanical response was obtained by using NH4HCO3 as space holder; and (iii) Ti matrix hardening when the interconnected porosity was 36–45% of total porosity. Finally, the advantages and limitations of the PM techniques employed, towards an industrial implementation, were discussed.

25 May 2020 in Metals
Verified
Journal Article
Open access
PDF file
ACAna Civantos
Ana Civantos
MGMercè Giner
Mercè Giner
PTPaloma Trueba
Paloma Trueba
SFSheila Lascano Farak
Sheila Lascano Farak
MMMaría-José Montoya-García
María-José Montoya-García
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
A great variety of powder metallurgy techniques can produce biomimetic porous titanium structures with similar mechanical properties to host bone tissue. In this work, loose sintering and space holder techniques, two frequently used metallurgical techniques, are compared to evaluate the influences of porosity (content, size, morphology and wall roughness), mechanical properties (stiffness and yield strength) and in-vitro cellular responses (adhesion and proliferation of myoblasts and osteoblasts). These comparisons are made to achieve the best balance between biomechanical and bifunctional behavior of a partial porous implant for cortical bone replacement. Cell adhesion (filopodia presence) and spreading were promoted on both porous surfaces and fully dense substrates (non-porous control surfaces). Porous scaffold samples designed using 50 vol.% NaCl space holder technique had an improved bioactive response over those obtained with the loose sintering technique due to higher roughness and scaffold pore diameter. However, the presence of large and heterogeneous pores compromises the mechanical reliability of the implant. Considering both scenarios, the substrates obtained with 40 vol.% NH4HCO3 and pore size ranges between 100 and 200 μm provide a balanced optimization of size and strength to promote in-vitro osseointegration.

13 June 2015 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
JPJ. J. Pavón
J. J. Pavón
PTPaloma Trueba
Paloma Trueba
JRJosé Antonio Rodríguez-Ortiz
José Antonio Rodríguez-Ortiz
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández

28 January 2020 in Metals
Verified
Journal Article
Open access
PDF file
PTPaloma Trueba
Paloma Trueba
Ana M. BeltranAna M. Beltran
Ana M. Beltran
JBJosé Manuel Bayo
José Manuel Bayo
JRJosé Antonio Rodríguez-Ortiz
José Antonio Rodríguez-Ortiz
D. F. LariosD. F. Larios
D. F. Larios
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
The discrepancy between the stiffness of commercially pure titanium and cortical bone tissue compromises its success as a biomaterial. The use of porous titanium has been widely studied, however, it is still challenging to obtain materials able to replicate the porous structure of the bones (content, size, morphology and distribution). In this work, the freeze-casting technique is used to manufacture cylinders with elongated porosity, using a home-made and economical device. The relationship between the processing parameters (diameter and material of the mold, temperature gradient), microstructural features and mechanical properties is established and discussed, in terms of ensuring biomechanical and biofunctional balance. The cylinders have a gradient porosity suitable for use in dentistry, presenting higher Young’s modulus at the bottom, near the cold spot and, therefore better mechanical resistance (it would be in contact with a prosthetic crown), while the opposite side, the hot spot, has bigger, elongated pores and walls.

22 November 2019 in Metals
Verified
Journal Article
Open access
PDF file
SCSandra M. Castillo
Sandra M. Castillo
SMSergio Muñoz Moreno
Sergio Muñoz Moreno
PTPaloma Trueba
Paloma Trueba
EDEduardo Diaz
Eduardo Diaz
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
In the present work, the use of porous titanium is proposed as a solution to the difference in stiffness between the implant and bone tissue, avoiding the bone resorption. Conventional powder metallurgical technique is an industrially established route for fabrication of this type of material. The results are discussed in terms of the influence of compaction pressure and sintering temperature on the porosity (volumetric fraction, size, and morphology) and the quality of the sintering necks. A very good agreement between the predicted values obtained using a simple 2D finite element model, the experimental uniaxial compression behavior, and the analytical model proposed by Nielsen, has been found for both the Young’s modulus and the yield strength. The porous samples obtained by the loose sintering technique and using temperatures between 1000 °C −1100 °C (about 40% of total porosity) are recommended for achieving a suitable biomechanical behavior for cortical bone partial replacement.

11 February 2021 in Metals
Verified
Journal Article
Open access
PDF file
JRJesús E. González Ruíz
Jesús E. González Ruíz
GOGabriela De Armas Ortiz
Gabriela De Armas Ortiz
JNJeidy Negrin
Jeidy Negrin
Ana M. BeltranAna M. Beltran
Ana M. Beltran
PTPaloma Trueba
Paloma Trueba
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
Ti6Al4V samples, obtained by selective laser melting (SLM), were subjected to successive treatments: acid etching, chemical oxidation in hydrogen peroxide solution and thermochemical processing. The effect of temperature and time of acid etching on the surface roughness, morphology, topography and chemical and phase composition after the thermochemical treatment was studied. The surfaces were characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction and contact profilometry. The temperature used in the acid etching had a greater influence on the surface features of the samples than the time. Acid etching provided the original SLM surface with a new topography prior to oxidation and thermochemical treatments. A nanostructure was observed on the surfaces after the full process, both on their protrusions and pores previously formed during the acid etching. After the thermochemical treatment, the samples etched at 40 °C showed macrostructures with additional submicro and nanoscale topographies. When a temperature of 80 °C was used, the presence of micropores and a thicker anatase layer, detectable by X-ray diffraction, were also observed. These surfaces are expected to generate greater levels of bioactivity and high biomechanics fixation of implants as well as better resistance to fatigue.