Yaohui Wang

Dr. Yaohui Wang

Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Journal of Ethnopharmacology
Verified
Journal Article
Closed access
JWJian Wu
Jian Wu
XZXing-Xing Zhang
Xing-Xing Zhang
ZXzou xi
zou xi
MWMin Wang
Min Wang
HWHong-Xing Wang
Hong-Xing Wang
SMSun qing Min
Sun qing Min

8 December 2021 in Superconductor Science and Technology
Verified
Journal Article
Closed access
YWYaohui Wang
Yaohui Wang
Qiuliang WangQiuliang Wang
Qiuliang Wang
HWHui Wang
Hui Wang
SCShunzhong Chen
Shunzhong Chen
XHXinning Hu
Xinning Hu
FLFeng Liu
Feng Liu
Active shielding technology has been widely applied to the superconducting magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR) magnets design, revealing excellent performance on the stray field control. For such a highly homogeneous field superconducting magnet design, an appropriate optimization strategy is essential to guarantee the magnetic field homogeneity in the central region and the expected 5 Gauss line range, especially for the ultrahigh field superconducting magnet. Based on the compensating field optimization method, an actively-shielded whole-body 14 T MRI magnet and an actively-shielded 1.3 GHz NMR magnet were presented, and detailed analyses were conducted to evaluate the feasibility of the designs. The developed magnet design method, coil pattern, wire arrangement, and stress/strain adjustment will be used to guide the corresponding project implementation.

1 May 2020 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
YWYaohui Wang
Yaohui Wang
QWQiuliang Wang
Qiuliang Wang
JLJianhua Liu
Jianhua Liu
JCJunsheng Cheng
Junsheng Cheng
FLFeng Liu
Feng Liu
An extremely-high field nuclear magnetic resonance (NMR) spectrometer has the potential to significantly augment the resolution and sensitivity of the atomic resonance spectrum, which will significantly boost the development of a range of scientific areas. The success of an extremely-high field NMR spectrometer depends to a great extent on the development of a superconducting magnet system. A high-temperature superconducting (HTS) insert magnet and low-temperature superconducting (LTS) shim coils design scheme for a 27 T NMR spectrometer is proposed in this work. A LTS background magnet was used to generate a 15 T magnetic field in the central area and the designed HTS insert magnet contributed the remaining 12 T magnetic field. The HTS insert magnet adopted notch double-pancake (DP) optimization to improve the rough magnetic field distribution in the central area to a highly-homogeneous level, and shim compensation schemes were proposed for the hybrid magnet to eliminate the inhomogeneous magnetic field components in the practical fabrication. The HTS insert magnet design had a current margin of 45.64% in terms of the perpendicular magnetic field intensity and the maximum hoop stress was reduced to 260 MPa with binding. There were in total eight shim coils, including two Nb 3 Sn zonal coils located between the insert magnet and the background magnet and six NbTi tesseral coils placed outside the background magnet. The magnet system will be fabricated in the near future.

3 August 2022 in Frontiers in Physiology
Verified
Journal Article
Open access
BHBi Honglun
Bi Honglun
XXXia Xu
Xia Xu
Xiaowei LiXiaowei Li
Xiaowei Li
YWYaohui Wang
Yaohui Wang
SZShutang Zhou
Shutang Zhou
Yongping HuangYongping Huang
Yongping Huang
Male fertility is essential for reproduction and population growth in animals. Many factors affect male fertility, such as courtship behavior, sperm quantity, and sperm motility, among others. Seminal Fluid Proteins (SFPs) are vital components of seminal fluid in the male ejaculate, which affect male fertility, sperm activation, and female ovulation. However, the knowledge of SFPs is insufficient; the function of many SFPs remains unknown, and most described functions were mainly characterized in Drosophila or other laboratory models. Here, we focus on the Serine protease 2 (Ser2) gene in the lepidopteran pest Spodoptera litura. The Ser2 gene was specifically expressed in male adults. Disruption of the Ser2 gene mediated by CRISPR/Cas9 induced male sterility but females remained fertile. PCR-based detection of the next-generation mutants showed that male sterility was stably inherited. The qRT-PCR analysis of SlSer2 mutants showed that motor protein family genes and structural protein family genes were down-regulated, while protein modification family genes were up-regulated, suggesting that SlSer2 may be involved in sperm movement and activity. These results demonstrate that Ser2 is an important component of SFPs in seminal fluid and was identified for a useful sterile gene for pest control that may lead to new control strategies for lepidopteran insect pests such as S. litura.

27 January 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
Zhifeng ChenZhifeng Chen
Zhifeng Chen
CLCongyu Liao
Congyu Liao
XCXiaozhi Cao
Xiaozhi Cao
BPBenedikt A Poser
Benedikt A Poser
ZXZhongbiao Xu
Zhongbiao Xu
BBBerkin Bilgic
Berkin Bilgic

26 February 2018 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
YYYali Yue
Yali Yue
YLYongkang Liu
Yongkang Liu
LSLina Song
Lina Song
XCXiao Chen
Xiao Chen
YWYaohui Wang
Yaohui Wang
ZWZhongqiu Wang
Zhongqiu Wang
Low-grade fibromyxoid sarcoma (LGFMS) is a distinctive slow growing soft tissue neoplasm, mostly affecting young individuals with no gender difference. It usually arises in deep soft tissue of the lower limbs and trunk, but few cases of LGFMS located in pelvis have been reported. We describe the magnetic resonance imaging(MRI) features of LGFMS located in the anterior pelvic wall of a 21-year-old female and correlate them with clinicopathological features. The tumor was completely resected and there is no recidivism during the follow-up one year. We report on the radiological findings of LGFMS with histological correlation. Awareness of the imaging features may be useful for the diagnosis of LGFMS and helpful to distinguish among mimics.