At the present stage of electric power industry development, special attention is being paid to the development and research of new efficient energy sources. The use of hydrogen fuel cells is promising for remote autonomous power supply systems. The authors of the paper have developed the structure and determined the optimal composition of a hybrid generation system based on hydrogen fuel cells and battery storage and have conducted studies of its operating modes and for remote consumers’ power supply efficiency. A simulation of the electromagnetic processes was carried out to check the operability of the proposed hybrid generation system structure. The simulation results confirmed the operability of the structure under consideration, the calculation of its parameters reliability and the high quality of the output voltage. The electricity cost of a hybrid generation system was estimated according to the LCOE (levelized cost of energy) indicator, its value being 1.17 USD/kWh. The factors influencing the electricity cost of a hydrogen generation system have been determined and ways for reducing its cost identified.
The article contains current information on the development of energy-efficient technologies of wind–diesel hybrid systems (WDHS) for decreasing organic fuel consumption. As a result of the review, three research directions are identified: WDHS design optimization, the main equipment and control system improvements. A comparison of their effectiveness is presented. The methods of selecting WDHS configuration, equipment capacities and location, the optimization algorithms and objective functions used are described and WDHS project feasibility calculation results are presented. The methods to improve energy efficiency of WDHS major units’ (diesel generator (DG) and wind turbine (WT)) are considered. The methods to decrease diesel fuel consumption using special devices and energy storage system are presented. Special attention is paid to WDHS operating modes’ control methods and strategies, as well as to algorithms providing the efficient system operation. As a result, recommendations for the design of both isolated and on-grid WDHS are formulated.
The article is devoted to the problem of reducing fuel consumption in a diesel generator set (DGS) as a part of a wind-diesel power plant (WDPP). The object of the research is a variable speed DGS. The goal is to develop the WDPP intelligent control system, providing an optimal shaft speed of an internal combustion engine (ICE). The basis of the intelligent control system is an economy mode setting device (EMSD), which controls the fuel supply to the ICE. The functional chart of EMSD has been presented. The main EMSD blocks contain a controller and an associative memory block. The associative memory block is a software model of an artificial neural network that determines the optimal shaft speed of the ICE. An algorithm for the WDPP intelligent control system has been developed and tested using the WDPP Simulink model. The EMSD prototype has been created, and its research has been conducted. Dependences of the change in specific and absolute fuel consumption on the load power have been obtained for two 4 kW DGS: with constant rotation speed and variable rotation speed DGS with EMSD. It has been established that the use of EMSD in the mode of low loads allow one to reduce fuel consumption by almost 30%. The error in determining the optimal engine speed using EMSD prototype is not more than 15%.
Continuous pulse width modulation (CPWM) and discontinuous pulse width modulation (DPWM) strategies are used to control voltage source inverter operation. CPWM strategies allow for the reduction of total harmonic distortion values, while DPWM strategies provide a more effective reduction in inverter switching losses. The paper is devoted to the problem of improving the three-phase voltage source inverter efficiency by a controlled transition from CPWM to DPWM. The article proposes an adjustable discontinuous pulse width modulation (ADPWM) method, which means a transition from space vector PWM (refers to CPWM strategies) to DPWM in all inverter phases when the switches’ temperatures exceed the allowable value in at least one of the inverter phases. The method flowchart is presented and an algorithm for modifying the envelope curve within one sector is given. In order to test the ADPWM method a Simulink-model of a three-phase voltage source inverter and its control system were developed. A study of the proposed ADPWM method’s efficiency in comparison with CPWM, PCDPWM and NCDPWM methods was carried out using a Simulink-model. It was established that the proposed ADPWM method provides dynamic losses reduction in the inverter switches by 2.86 times compared to CPWM and by 1.89 times compared to PCDPWM and NCDPWM methods. Power supply systems for medium and high-power AC motors provide a promising area for application of the proposed ADPWM method.
Three-phase four-wire voltage inverters are commonly used in energy complexes based on distributed generation sources (solar panels, wind power plants, hydrogen fuel cells) and accumulator batteries. They allow to power loads, including single-phase ones, which require neutral point connection. In these cases, phase voltage formed by spatial pulse-width modulation (PWM) methods considerably differs from sinusoidal waves and has high total harmonic distortions of voltage and current curves. This article is devoted to research into the authors’ control method of a three-phase four-wire inverter, allowing for the rectification of the form of phase voltage supplying the load when applying the most common PWM (SVPWM, DPWMMIN, DPWMMAX, GDPWM) methods. The description of the method and its research results by simulation modeling and test bench are presented in the article. The simulation modeling was carried out by the developed Simulink-model of the three-phase four-wire inverter and its control system. The modeling results showed that the method application ensures sinusoidal voltage form when applying any PWM method. At this, THDU was reduced from 21.56% to 4.39%, while THDI was reduced from 21.16% to 1.69%. Experimental tests were carried out by a test bench featuring an uninterruptible power supply source. The authors researched the inverter operation as a component of the test bench under the control of the proposed method to form neutral point voltage. The experimental test results coincided with the simulation modeling results.
1 December 2023 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Methodology of constructing coil winding electrical circuits for salient-pole stator of electrical permanent-magnet machines on the rotor is proposed, which is based on the required number of pole pairs (synchronous speed) and the number of phases. The methodology algorithm is based on determining the value of the number of stator teeth as the closest to the number of rotor poles number value, multiple of phase number, which provides a sufficient level of pitch coefficient and winding coefficient. The algorithm was tested by several examples of constructing synchronous machines winding circuits, known from electrical engineering theory and practice, including mass-produced ones. In all the examples, if the proposed methodology guidelines were formally and strictly followed, the correct circuit designs came out as a result. For high power motor pilot design, one and the same machine design variants were compared, having thirty six slots on stator, three-phase and nine-phase windings, synthesized according to the proposed algorithm for thirty two-pole rotor. Engine torque calculation with both circuit options performed by finite elements method showed the nine-phase winding developed torque advantage by 20%, due to less discretion of MMF slot distribution.