Empathy is a key element of “Patient and Family Centered Care”, a clinical approach recommended by the American Academy of Pediatrics. However, there is a lack of validated tools to evaluate paediatrician empathy. This study aimed to validate the Visual CARE Measure, a patient rated questionnaire measuring physician empathy, in the setting of a Pediatric Emergency Department (ED). The empathy of physicians working in the Pediatric ED of the University Hospital of Udine, Italy, was assessed using an Italian translation of the Visual Care Measure. This test has three versions suited to different age groups: the 5Q questionnaire was administered to children aged 7–11, the 10Q version to those older than 11, and the 10Q–Parent questionnaire to parents of children younger than 7. The internal reliability, homogeneity and construct validity of the 5Q and 10Q/10Q–Parent versions of the Visual Care Measure, were separately assessed. The influence of family background on the rating of physician empathy and satisfaction with the clinical encounter was also evaluated. Seven physicians and 416 children and their parents were included in the study. Internal consistency measured by Cronbach’s alpha was 0.95 for the 10Q/10Q–Parent versions and 0.88 for the 5Q version. The item-total correlation was > 0.75 for each item. An exploratory factor analysis showed that all the items load onto the first factor. Physicians’ empathy scores correlated with patients’ satisfaction for both the 10Q and 10Q–Parent questionnaires (Spearman’s rho = 0.7189; p < 0.001) and for the 5Q questionnaire (Spearman’s rho = 0.5968; p < 0,001). Trust in the consulting physician was lower among immigrant parents (OR 0.43. 95% CI 0.20–0.93). The Visual Care Measure is a reliable second-person test of physician empathy in the setting of a Pediatric Emergency Room. More studies are needed to evaluate the reliability of this instrument in other pediatric settings distinct from the Emergency Room and to further evaluate its utility in measuring the impact of communication and empathy training programmes for healthcare professionals working in pediatrics.
Ultrasound Superior Vena Cava (SVC) flow assessment is a common measure of systemic and cerebral perfusion, although accuracy is limited. The aim of this study was to evaluate whether any improvements in accuracy could be achieved by measuring stroke distance from the instantaneous mean velocity, rather than from peak velocity, and by directly tracing area from images obtained with a high frequency linear probe. Paired phase contrast magnetic resonance imaging (PCMRI) and ultrasound assessments of SVC flow were performed in a pilot cohort of 7 infants. Median postnatal age, corrected gestation and weight at scan were 7 (2–74) days, 34.8 (31.7–37.2) weeks 1870 (970–2660) g. Median interval between PCMRI and ultrasound scans was 0.3 (0.2–0.5) h. The methodology trialed here showed a better agreement with PCMRI (mean bias −8 mL/kg/min, LOA −25–+8 mL/kg/min), compared to both the original method reported by Kluckow et al. (mean bias + 42 mL/kg/min, LOA −53–+137 mL/kg/min), and our own prior adaptation (mean bias + 23 mL/kg/min, LOA −25–+71 mL/kg/min). Ultrasound assessment of SVC flow volume using the modifications described led to enhanced accuracy and decreased variability compared to prior techniques in a small cohort of premature infants.
Background: Diastolic dysfunction often precedes systolic dysfunction and provides opportunity for management strategies. We aim to present reference ranges for diastolic function parameters in stable preterm infants at 2 timepoints. Methods: Ultrasound scans of clinically stable preterm infants < 30 weeks gestation with no antenatal or postnatal complications were analysed for left heart size, mitral blood flows, myocardial velocities and shortening during the early (3 to 21 days) and late (corrected gestation 34 to 37 weeks) neonatal period. Results: 92 early scans and 64 late scans were included. Mitral blood flow and myocardial velocities increased with augmented atrial function leading to higher EA and e’a’ ratios and with relatively high Ee’ ratio. Conclusion: We present reference values for many left ventricular multimodal diastolic ultrasound parameters in preterm infants with uncomplicated fetal and neonatal development to guide prospective studies that explore diastolic function and diastolic heart failure in preterm infants.