The QT interval is an electrocardiographic measure representing the sum of ventricular depolarization and repolarization, estimated by QRS duration and JT interval, respectively. QT interval abnormalities are associated with potentially fatal ventricular arrhythmia. Using genome-wide multi-ancestry analyses (>250,000 individuals) we identify 177, 156 and 121 independent loci for QT, JT and QRS, respectively, including a male-specific X-chromosome locus. Using gene-based rare-variant methods, we identify associations with Mendelian disease genes. Enrichments are observed in established pathways for QT and JT, and previously unreported genes indicated in insulin-receptor signalling and cardiac energy metabolism. In contrast for QRS, connective tissue components and processes for cell growth and extracellular matrix interactions are significantly enriched. We demonstrate polygenic risk score associations with atrial fibrillation, conduction disease and sudden cardiac death. Prioritization of druggable genes highlight potential therapeutic targets for arrhythmia. Together, these results substantially advance our understanding of the genetic architecture of ventricular depolarization and repolarization.
Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients’ heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5–5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.
Background: Wearables with integrated electrocardiogram (ECG) acquisition have made single-lead ECGs widely accessible to patients and consumers. However, the 12-lead ECG remains the gold standard for most clinical cardiac assessments. In this study, we developed a neural network to reconstruct 12-lead ECGs from single-lead and dual-lead ECGs, and evaluated the mathematical accuracy. Methods: We used lead I or leads I and II from 9514 individuals from the Physikalisch-Technische Bundesanstalt (PTB-XL) cohort and a generative adversarial network, with the aim of recreating the missing leads from the 12-lead ECG. ECGs were divided into training, validation, and testing (10%). Original and recreated leads were measured with a commercially available algorithm. Differences in means and variances were assessed with Student’s t-tests and F-tests, respectively. Calibration and bias were assessed with Bland-Altman plots. Inter-lead correlations were compared in original and recreated ECGs. Results: The variability of precordial ECG amplitudes is significantly reduced in recreated ECGs compared to real ECGs (all p < 0.05), indicating regression-to-the-mean. Amplitude averages are recreated with bias (p < 0.05 for most leads). Reconstruction errors depend on the real amplitudes, suggesting regression-to-the-mean (R2 between target and error in R-peak amplitude in lead V3: 0.92). The relations between lead markers have a similar slope but are much stronger due to reduced variance (R-peak amplitude R2 between leads I and V3, real ECGs: 0.04, recreated ECGs: 0.49). Using two leads does not significantly improve 12-lead recreation. Conclusions: AI-based 12-lead ECG reconstruction results in a regression-to-the-mean effect rather than personalized output, rendering it unsuitable for clinical use.
The 3-dimensional spatial and 2-dimensional frontal QRS-T angles are measures derived from the vectorcardiogram. They are independent risk predictors for arrhythmia, but the underlying biology is unknown. Using multi-ancestry genome-wide association studies we identify 61 (58 previously unreported) loci for the spatial QRS-T angle (N = 118,780) and 11 for the frontal QRS-T angle (N = 159,715). Seven out of the 61 spatial QRS-T angle loci have not been reported for other electrocardiographic measures. Enrichments are observed in pathways related to cardiac and vascular development, muscle contraction, and hypertrophy. Pairwise genome-wide association studies with classical ECG traits identify shared genetic influences with PR interval and QRS duration. Phenome-wide scanning indicate associations with atrial fibrillation, atrioventricular block and arterial embolism and genetically determined QRS-T angle measures are associated with fascicular and bundle branch block (and also atrioventricular block for the frontal QRS-T angle). We identify potential biology involved in the QRS-T angle and their genetic relationships with cardiovascular traits and diseases, may inform future research and risk prediction.
Since the introduction of digital electrocardiographs, high-pass filters have been necessary for successful analog-to-digital conversion with a reasonable amplitude resolution. On the other hand, such high-pass filters may distort the diagnostically significant ST-segment of the ECG, which can result in a misleading diagnosis. We present an inverting filter that successfully undoes the effects of a 0.05 Hz single pole high-pass filter. The inverting filter has been tested on more than 1600 clinical ECGs with one-minute durations and produces a negligible mean RMS-error of 3.1*10−8 LSB. Alternative, less strong inverting filters have also been tested, as have different applications of the filters with respect to rounding of the signals after filtering. A design scheme for the alternative inverting filters has been suggested, based on the maximum strength of the filter. With the use of the suggested filters, it is possible to recover the original DC-coupled ECGs from AC-coupled ECGs, at least when a 0.05 Hz first order digital single pole high-pass filter is used for the AC-coupling.
Background: The association between type 2 diabetes and electrocardiographic (ECG) markers are incompletely explored and the dependence on diabetes duration is largely unknown. We aimed to investigate the electrocardiographic (ECG) changes associated with type 2 diabetes over time. Methods: In this cross-sectional study, we matched people with type 2 diabetes 1:1 on sex, age, and body mass index with people without diabetes from the general population. We regressed ECG markers with the presence of diabetes and the duration of clinical diabetes, respectively, adjusted for sex, age, body mass index, smoking, heart rate, diabetes medication, renal function, hypertension, and myocardial infarction. Results: We matched 988 people with type 2 diabetes (332, 34% females) with as many controls. Heart rate was 8 bpm higher ( p < 0.001) in people with vs. without type 2 diabetes, but the difference declined with increasing diabetes duration. For most depolarization markers, the difference between people with and without type 2 diabetes increased progressively with diabetes duration. On average, R-wave amplitude was 6 mm lower in lead V5 ( p < 0.001), P-wave duration was 5 ms shorter ( p < 0.001) and QRS duration was 3 ms ( p = 0.03). Among repolarization markers, T-wave amplitude (measured in V5) was lower in patients with type 2 diabetes (1 mm lower, p < 0.001) and the QRS-T angle was 10 degrees wider ( p = 0.002). We observed no association between diabetes duration and repolarization markers. Conclusions: Type 2 diabetes was independently associated with electrocardiographic depolarization and repolarization changes. Differences in depolarization markers, but not repolarization markers, increased with increasing diabetes duration.